SX RR Test

17:10 Found and coarsely aligned the return beam
  • cube rotation stage 180.05
  • cube linear stage -1
  • bayside stages -74.4,-51, 35
  • hexapod -1.1, 1.8, 5.5, 87, -145

17:15 12 mode closed loop.
  • Improve T/T and focus, but still uneven

17:17 400 mode closed loop
  • Nice even pupils
  • hexapod -1.10, 1.83, 5.53, 85.8, -145.5

17.26 400 mode closed loop
  • move cube rotation back and forth to see vignetting
  • best cube rotation position = 180.02
  • not dust spot at this position seen (no dust diffraction pattern)

17:36 Move bayside Z to get better focus on N3.75
  • better focus at bayside Z = 42 smile

17:50 N30 camera focus
  • best focus = 48.8

17:58 Move re-rotator
  • moved to 55.953, get strips along left side of pupil
  • nominal = 54.903
  • moved to 53.853, get stripes along lower edge of pupil

18:20 Move camera lens
  • Move Y by delta 8 um. no change in illumination pattern
  • move X by delta 10 um. no change in illumination pattern

18:48 PresetAO and AcquireRefAO from AOS Command GUI
  • Bin 1
  • 990 Hz
  • 7.5 mag
  • Recon = KL_v20, Rec_20160229_184300
  • Distrubance = CmdDistrub_20160314_190412

19:00
  • bayside stage position -75.43, -51, 48.8
  • subwin SW 1 940 940 128 128
  • hexapod -1.10, 1.93, 5.58, 83

19:35
  • Bin 1, 99 Hz
  • No disturbance
  • No NCPA
  • 193557
  • 193725

19:55 LUCI Dark via Acquire PISCES dark button
  • P-Beta
  • 50 luci darks
  • /home/AOeng2/aoroot/calib/wfs/W1/luci/backgrounds/bin1/20170113_195557.fits_cube.fits

20:18 LUCI dark
  • Set exp time to 1.0 on variable inspector
  • H band
  • 10 frames
  • 20170113_202025

20:21 Optical Loop data
  • 202159
  • 10 frames, 1 sec exp

20:42 0.8" seeing
  • Load Distrubance disturb/dist_flao2_KL_v18_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd1983.fits
  • Had to stop/start wfsarbitrator to get saving of LUCI image via Optical Loop data
  • gain .59, .45, .36
  • 204905

20:52 0.8"/2 seeing
  • 400
  • gain 0.75, 0.5, 0.45
  • 205315

21:05 1.0"/2 seeing
  • gain .79, .55, . 40
  • 210249
  • //dataA/readout1/DATA/20170114/luci1.20170114.0033.fits on luci machine
  • 211056

21:12 1.2"/2 seeing
  • gain 0.9, 0.65, 0.55
  • 211407
  • //dataA/readout1/DATA/20170114/luci1.20170114.0034.fits * 211441

21:20 2.0"/2 seeing
  • gain 0.95, 0.65, 0.5
  • 212251
  • //dataA/readout1/DATA/20170114/luci1.20170114.0035.fits
  • 212416

21:26 2.0"/2 seeing, 300 mode, 7.4 mag (above)
  • 212623
  • //dataA/readout1/DATA/20170114/luci1.20170114.0036.fits
  • 212802

21:31 2.0"/2 seeing, 400 mode, 9.4 mag
  • 0.90, 0.15, 0.1 (as much as we could apply
  • 213708 BAD SET!!
  • //dataA/readout1/DATA/20170114/luci1.20170114.0037.fits

21:40 2.0"/2 seeing, 300 mode, 9.4 mag
  • gain 0.95, 0.2, 0.15
  • 214012
  • //dataA/readout1/DATA/20170114/luci1.20170114.0038.fits (H band)
  • //dataA/readout1/DATA/20170114/luci1.20170114.0039.fits (J band)
  • 214152

21:43 2.0"/2 seeing, 400 mode, 9.4 mag * 214310 * //dataA/readout1/DATA/20170114/luci1.20170114.0040.fits (J band) (safe skip while saving)

21:46 No Disturb, 400 mode, 9.4 mag
  • 214605
  • //dataA/readout1/DATA/20170114/luci1.20170114.0041.fits (J band) (saturated)

22:01 2.0"/2 seeing, bin 2, 153 mode, 10.4 mag
  • Rec 20160404_203208
  • 220137
  • //dataA/readout1/DATA/20170114/luci1.20170114.0043.fits (J band)

22:20 No Disturb, 14.3, bin 4, 36 modes, 300 Hz
  • 221946
  • //dataA/readout1/DATA/20170114/luci1.20170114.0057.fits (J band)
  • 222407

22:32 No Disturbance, 7.5 mag, bin 1, 400 modes, 990 Hz
  • 223213
  • //dataA/readout1/DATA/20170114/luci1.20170114.0058.fits (H band) (0.5 integration time)
  • //dataA/readout1/DATA/20170114/luci1.20170114.0059.fits (H band) (1.0 integration time)
  • 223542
  • saved new flat = 20160117_rr_flat_400_modes_or_someing_2.sav
  • dark
    • //dataA/readout1/DATA/20170114/luci1.20170114.0060.fits (H band) (1.0 integration time)
    • //dataA/readout1/DATA/20170114/luci1.20170114.0061.fits (H band) (0.5 integration time)

-- %USERSIG{DougMiller - 2017-01-13}%
Topic revision: r2 - 13 Jan 2017, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback