SX Re-rotator tests

16:33 Had SX loop running an hour ago, but the pupil centering routine seemed to be jumpy. The diff would go from 0.04 to 0.15 to -0.13 etc. Stopped loop, set loop parameters and closed loop. Seems stable now.

16:50 Rotator at 300
luci1 image rotator angle Star Position Comment
335 53.4 1101 838 0 0
334 75.4 1129 843 0 0
336 97.4 1146 866 0 0

17:01 Move to center of circle at 300
luci1 image rotator angle Star Position Comment
337 75.4 1147 835 0 -1.4
338 75.4 1109 851 1.5 0
339 75.4 1100 833 1.5 -1.5
340 75.4 1118 869 1.5 1.5
341 75.4 1120 872 1.0 2.0
342 75.4 1130 877 1.0 2.4
343 75.4 1125 879 1.4 2.4
344 75.4 1120 879 1.7 2.1
345 75.4 1109 876 2.3 1.7
346 75.4 1107 875 2.4 1.6
347 75.4 1108 875 2.3 1.6

17:24 move rotator to 210
luci1 image rotator angle Star Position Comment
349 98.4 1112 877 0 0
348 120.4 1106 906 0 0
350 144.4 1080 923 0 0

17:36 move to center 1075.5 886
luci1 image rotator angle Star Position Comment
348 120.4 1106 906 0 0
351 120.4 1117 930 0 2.0
352 120.4 1093 882 0 -2.0
353 120.4 1113 874 -1.5 -2.0
354 120.4 1070 887 1.6 -2.3
355 120.4 1071 887 1.5 -2.3
356 120.4 1073 886 1.4 -2.3
357 120.4 1074 886 1.3 -2.3
358 120.4 1077 885 1.1 -2.3
360 120.4 1076 883 1.1 -2.4
361 120.4 1073 885 1.3 -2.4
362 120.4 1075 885 1.2 -2.3
363 120.4 1077 886 1.1 -2.3

18:01 Rotate to 120
365 143.4 1103 898 0 0
364 165.4 1075 892 0 0
366 187.4 1059 867 0 0

18:05 Center to 1096 861.5
luci1 image rotator angle Star Position Comment
364 165.4 1075 892 0 0
365 165.4 1116 894 -2.3 1.4
366 165.4 1104 898 -1.5 1.4
367 165.4 1086 863 -1.5 -1.4
370 165.4 1083 857 -1.5 -2.0
371 165.4 1096 858 -2.3 -1.5
372 165.4 1098 860 -2.4 -1.3
373 165.4 1096 862 -2.2 -1.2
       

18.55 rotate to 30
luci1 image rotator angle Star Position Comment
375 188.4 1088 873 0 0
374 210.4 1093 847 0 0
376 232.4 1114 831 0 0

19:05 Move Center to 1125 866.5
luci1 image rotator angle Star Position Comment
1 210.4 1115 876 -0.6 2.7
2 210.4 1113 876 -0.6 2.7
3 210.4 1122 872 -1.3 2.7
4 210.4 1122 866 -1.5 2.3
5 210.4 1124 865 -1.7 2.3
6 210.4 1126 864 -1.8 2.3
7 210.4 1125 866 -1.7 2.4

17 K 30  
18 FeII 30 1120 1102 -1.7 2.4
19 FeII 75 1101 1108 -2.6 0.9
20 K 75    
21 K 120    
22 FeII 120 1073 1108 -2.2 -1.2
23 FeII 165 1069 1099 -0.9 -2.3
24 K   165  
25 K   210  
26 FeII 210 1067 1075 1.1 -2.3
27 FeII 255 1064 1066 2.5 -0.7
28 K 255    
29 K 300    
30 FeII 300 1078 1075 2.3 1.6
31 FeII 345 1087 1076 0.4 2.8
32 K 345    

-- %USERSIG{DougMiller - 2016-12-13}%
Topic revision: r2 - 13 Dec 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback