DX LBTI Tests

20:30 - 21:20
  • Removed actuators 217 218 219 223 from current do-not-use list
  • Added act 223 to position do-not-use list
  • act 219, 218 and 217 have a bit higher current, but not bad
  • LBTI will try closed loop and elevation changes

21:50 LBTI finds at 50 elevation can get ~200 modes now compared to 130 before

22:22 Removed 358 from cur and pos do-not-use list

22:29 Added 357 to pos do-not-use list. After 358 was added back in, it looked fine but 357 position was bad
  • Get large jump in 358 current.

22:35 Remove 357 and add 358 to pos do-not-use list

22:45 Add 358 to cur do-not-use list
  • Remove 367 from cur and pos do-not-use list
  • safe skip on Set

22:51 Add 367 to pos do-not-use list
  • wfs pupil looks better

22:56 Remove 340 from cur do-not-use list
  • Not good. big bite out of wfs pupil

23:02 Add 340 to pos do-not-use list
  • Add 340 to cur do-not-use list

-- %USERSIG{DougMiller - 2016-11-28}%
Topic revision: r1 - 28 Nov 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback