Daytime SX NCPA Measurements

15:07 Skip Frame and then repeated ICE error
  • Closed loop Bin 1
  • Stable
  • Something happened and see checkerboard patter on the top half of the current mirror control gui
  • Skip frame to 100%
  • Just sit there and repeat the error below
  • Pressed "Open" loop on WFS control GUI. Loop open OK
  • AdSec left in strange (high order) shape
  • Load default.sav. All OK
AdSecArbitrator_592|WAR|       365|2016-11-07 15:07:38.006362|             MAIN >  . 
20160711 15:07:39.0889 Alert: HighOrderOffload: HighOrderOffload vector ready
AdSecArbitrator_592|WAR|       366|2016-11-07 15:07:39.094132|             MAIN > Skip frame detected!
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN > Cannot dispatch alert: Outgoing.cpp:493: Ice::UnknownException:
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  . unknown exception:
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  . Traceback (most recent call last):
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .   File "aoarbitrator.py", line 184, in alert
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .     self._loop._fsm.SkfAlert()
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .   File "/home/AOeng2/aoroot/lib/python/AOArb_sm.py", line 601, in trans_sm
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .     getattr(self.getState(), attrib)(self, *arglist)
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .   File "/home/AOeng2/aoroot/lib/python/AOArb_sm.py", line 78, in SkfAlert
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .     self.Default(fsm)
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .   File "/home/AOeng2/aoroot/lib/python/AOArb_sm.py", line 89, in Default
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .     raise statemap.TransitionUndefinedException(msg)
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  . TransitionUndefinedException: 
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .    State: AOArbitrator.Ready
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .    Transition: SkfAlert
AdSecArbitrator_592|WAR|       367|2016-11-07 15:07:39.099144|             MAIN >  .

16:47 Found msgdrtb running on adsecsx under AOeng

Correct disturbance to use for manual NCPA: CmdDisturb _20160314_190412.fits

NCPA Measurements:

Defaults:

Z4=-30.1

Z5=-18

Z6=-6

Z7=4

Z8=12.9

Z9=9

Z10=-13.9

Z11=-0.2

Measured (only different ones will be noted):

Z6=-15

Z10=-5

Now it appears sensibly perfect.

330

18:33 UT Cable Chain Drive fault. Possibly my fault as I was spinning the rotator too quickly, I tried to hit the "HOLD" button, but accidentally hit "OFF" (they are right next to each other). Trying to turn it back on gave me the error.

300 We'll go by 60

Default values:

Z4 = -9.9

Z5 = -15

Z6 = 5

Z7 = 10

Z8 = 5

Z9 = -5

Z10 = 7.5

Z11 = - 11.5

Measured:

This one looks great as is. The first diffraction ring is complete and evenly illuminated.

240

Default Values:

Z4 = -3.8

Z5 = 5

Z6 = 50

Z7 = 10

Z8 = 0

Z9 = 4

Z10 = -10

Z11 = -13.3

Measured:

Z9 = -10

180

Default:

Z4 = 13.2

Z5 = 73

Z6 = -28

Z7 = 7.9

Z8 = 10

Z9 = -14

Z10 = 20

Z11 = -13.2

19:45

Had to restart system. Adsec started in an Unknown state and I had to try a few IDL commands to try to get it in a usable state: fsm_power_off() didn't work. fsm_power_on() put the adsec in a funny "power_off" state where it wouldn't power on because of a "generic network error". Restarted software again.

19:53 Still unable to recover adsec.

20:33 Had to start under UAO.

Measured

21:22 Cannot home bayside X

21:47 That was resolved, now the IDL server is down.

22::05 Giving up

-- %USERSIG{DougMiller - 2016-11-07}%
Topic revision: r4 - 07 Nov 2016, GregoryTaylor
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.