LUCI1/AO Commissioning

00:53 Start up system

01:00 Send PresetAO from AOS Command GUI
  • Load Recon and gain 0
  • "Close" on AdSec Control GUI

01:13 First ACE Preset
  • Failed
  • Forgot to remove file /tmp/acqpupils.fits

01:16 ACE Preset
  • Success

01:25 - 02:00 LUCI trouble communicating to IIF
  • SW Change during the day?

01:46 Modified autogain.conf
  • changed bin2_cycles from 10 to 5
  • changed bin3_cycled from 10 to 4
  • bin1 was 5 and bin4 was 4 already

02:45 - 02:55 LUCI Communication problems again

-- %USERSIG{DougMiller - 2016-10-26}%
Topic revision: r2 - 26 Oct 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.