SX and DX AO On-Sky Checkout

08:15 Getting ready

09:02 Jochen done. Switch to CentOS 6/7

09:14 Had clicked SetFlatAO and as soon as done, AdSec Control GUI said it has received a Rest command. From whom?

09:18 First preset. About 16 minutes to switch over both sides
  • Failed, no off-axis guide star
  • Pointing star

09:24 ACE Preset to AO195

09:42 Test Re-Close Loop button on FLAO GUI
  • on HW GUI check camera lens position
  • SX 29.98, -4,67
  • slide x to -100
  • Loop Opens
  • Click Re-CLose loop
  • loop closed with LNgains
  • Didn't see what TCS thought

09:51 Try again
  • Cam lens 29.71, -12.93
  • WFS Status AOSet
  • AdSec Status AOSet
  • TCS AO Open
  • AOSGUI LoopFault
  • Put cam Lens back
  • Click Re-Close Loop with LNgains
  • WFS Status LoopClosed
  • AdSec Status AORunning
  • TCS AO Closed
  • AOSGUI LoopClosed

09:59 Test DX
  • cam lens 31.10, 24.82
  • TCS loop open
  • Re-close loop
  • TCS loop closed
  • OK

10:42 SX re-close with Gopt running
  • cam lens 13.18, -25.98
  • Gopt is KO. Distrubance was not reloaded
  • Apply to Gopt was on so Opt Gain became small. Caused many skip frames

11:00 Re-Close loop on DX
  • cam lens 28.49, 27.82
  • slipe cam lens
  • set back
  • Send Distrubance
  • Click off Apply to Gopt
  • Load original gains
  • Wait for pupil to center
  • Apply original gains (had to choose and then apply them, recorded before open loop)
  • Click Apply to Gopt

11:37 SX test of Disturbance file automatically applied
  • cam lens -18.09, -29.15
  • force open loop
  • reclose loop
    • Disturbance file is now loaded
    • Opt gain changes a bit with the low gain, but not much. It is Green and OK
  • After

11:49 Barry send LUCI binoc script to AO195
  • Test Loop Open, force open loop
  • SX cam lens -29.92, -

12:07 Offset error
WFS arb log
999, 2.9918999999999998, True)
pyarg              |INF|      1524|2016-09-19 12:07:39.479104|             MAIN > offsetXY(): starting offset of -3.000, 2.982 mm
pyarg              |INF|      1525|2016-09-19 12:07:39.479281|             MAIN > offsetXYZ(): Focus correction (absolute): 0.000 mm
pyarg              |INF|      1526|2016-09-19 12:07:44.810345|             MAIN > offsetXY(): done
pyarg              |DEB|      1527|2016-09-19 12:07:44.810379|             MAIN > arbFunc offsetXYinternal done.

AOSL log
Mon Sep 19 12:07:39.426 2016 aos.OffsetXY{FLAO}.started - OffsetXY{FLAO}[86] (ofsx:2.99097[2.99097],ofsy:2.9919)
Mon Sep 19 12:07:44.818 2016 aos.OffsetXY{FLAO}.failed - OffsetXY{FLAO}[86] - Command interrupted
Mon Sep 19 12:08:53.103 2016 aos.Pause{FLAO}.started - Pause{FLAO}[5] 
Mon Sep 19 12:08:53.120 2016 aos.Pause{FLAO}.failed - Pause{FLAO}[5] - Illegal command for state AOArbitrator.LoopSuspended

IIF Log
Mon Sep 19 12:08:52.173 2016 right Offset command started for LUCIFER
Mon Sep 19 12:08:53.649 2016 left Offset alert for LUCIFER: Pause{FLAO}[5] - Illegal command for state AOArbitrator.LoopSuspended
Mon Sep 19 12:08:53.678 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav


-- %USERSIG{DougMiller - 2016-09-19}%
Topic revision: r2 - 19 Sep 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback