SX AO Testing

03:00 Xianyu installed Alfio's patch on DX side.

Preset and RunAO were OK Offset failed because

Hand over to Science

08:52

09:54 Authorize failed because AdSecs were not
Sat Sep 17 09:54:55.800 2016 TCS authorize alert for left LUCIFER at bentGregorianFront focus: Stop{FLAO}[120]
Sat Sep 17 09:54:55.814 2016 TCS authorize alert for left LUCIFER at bentGregorianFront focus: PresetFlat[122] - [AOException] LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
Sat Sep 17 09:54:55.828 2016 TCS authorize alert for right LUCIFER at bentGregorianFront focus: Stop{FLAO}[65]
Sat Sep 17 09:54:55.842 2016 TCS authorize alert for right LUCIFER at bentGregorianFront focus: PresetFlat[67] - [AOException] LoadShape: WARNING - adsecarb:Illegal command for state Ready (Load shape)
Sat Sep 17 09:54:55.856 2016 TCS authorize command failed for left LUCIFER at bentGregorianFront focus and right LUCIFER at bentGregorianFront focus
Sat Sep 17 09:56:41.936 2016 TCS authorize command started for left LUCIFER at bentGregorianFront focus and right LUCIFER at bentGregorianFront focus

10:07 ACE preset, RunAO on SX and DX
  • SX Bayside X Timeout
Sat Sep 17 10:07:36.436 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[130] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Sat Sep 17 10:07:36.451 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

pyarg              |INF|      2025|2016-09-17 10:07:26.152108|             MAIN > source_acq.acquire(): star found at X=503.88,Y=511.09
pyarg              |INF|      2026|2016-09-17 10:07:26.152147|             MAIN > source_acq.acquire(): current error X=-0.306 mm, Y=0.413 mm
pyarg              |ERR|      2027|2016-09-17 10:07:36.247298|             MAIN > Timeout error on baysidex (-5001) TIMEOUT_ERROR

10:07 Offset failed SX: RunAO failed so can not do offset DX: RunAO succeeded but since SX RunAO failed a Start AO was not sent to the DX side
Sat Sep 17 10:15:2Sat Sep 17 10:07:21.535 2016 left RunAO command started from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
Sat Sep 17 10:07:36.436 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[130] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Sat Sep 17 10:07:36.451 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
Sat Sep 17 10:12:21.883 2016 right RunAO alert for LUCIFER: AcquireRef{FLAO}[75] - FLAO: unknown exception from arbitrator
Sat Sep 17 10:12:21.899 2016 right RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
Sat Sep 17 10:15:28.695 2016 right Offset command started for LUCIFER
Sat Sep 17 10:15:29.742 2016 right Offset alert for LUCIFER: Pause{FLAO}[71] - Illegal command for state AOArbitrator.ReadyForStartAO
Sat Sep 17 10:15:29.769 2016 right Offset command failed for LUCIFER, Sound=offsetFailed.wav

10:23 SX PresetAO failed
  • Bayside X timeout
Sep 17 10:23:55.264 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[134] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Sat Sep 17 10:23:55.279 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

10:41 First successful Binocular Offset with Gopt and NCPA on. YEAH!

10:44 LUCI1 Dice5 script
  • Collect transform data on SX side
  • Test AO Offsets on both sides
  • Monocular script so Steve Click Psudeo-Monocular

10:53 DX offset failed
Sat Sep 17 10:52:42.958 2016 aos.Pause{FLAO}.failed - Pause{FLAO}[71] - [Exception] exception ::Ice::UnknownUserException{ unknown = AODefs::AOException}

adsecarb.R |WAR| 512|2016-09-17 10:52:42.950239| MAIN > Offloading: WARNING - adsecarb:Illegal command for state AORunning (TTOffload) 

11:02 Send binocular preset to Psuedo-Monocular Telescope
  • SX success
  • DX fail
Sat Sep 17 11:01:26.864 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[156]
Sat Sep 17 11:01:26.873 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[157] - FLAO: unknown exception from arbitrator
Sat Sep 17 11:01:26.887 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, pseudo-monocular active, Sound=presetFailed.wav

11:03 Send /LEFT preset to Psuedo-Monocular Telescope
  • SX success
  • DX fail
Sat Sep 17 11:03:54.837 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[158]
Sat Sep 17 11:03:54.850 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[159] - [AOException] presetAO: FATAL - Attaching to shared buffer mirrorctrl.L:TECHVIEWER_65536 (-3508) SLOT_NOT_FOUND_ERROR
Sat Sep 17 11:03:54.863 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, pseudo-monocular active, Sound=presetFailed.wav

11:05 Binocular Preset
  • SX success
  • DX fail
Sat Sep 17 11:06:40.732 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[160]
Sat Sep 17 11:06:40.742 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[161] - [AOException] presetAO: FATAL - Attaching to shared buffer mirrorctrl.L:TECHVIEWER_65536 (-3508) SLOT_NOT_FOUND_ERROR
Sat Sep 17 11:06:40.757 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, Sound=presetFailed.wav
  • SX CCD47 is Not Live
  • Change binning fixes it 11:20 LUCI Preset, Psuedo Monocular
  • Hacked LUCI script sent 0 Mag AO Ref Star
Sat Sep 17 11:20:36.829 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[167] 
Sat Sep 17 11:20:36.846 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[168] - [AOException] presetAO: WARNING - RETRY: Star too bright (estimated mag: 0.0). Minimum magnitude is 3.5 (-5002) VALUE_OUT_OF_RANGE_ERROR 
Sat Sep 17 11:20:36.875 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, offset, AO reference, pseudo-monocular active, Sound=presetFailed.wav 
* Jenny put in correct 8.65

11:24 at
Sep 17 11:27:16.106 2016 left Offset command started for LUCIFER, pseudo-monocular active 
Sat Sep 17 11:27:18.908 2016 right Offset alert for LUCIFER: Pause{FLAO}[71] - Illegal command for state AOArbitrator.PresetOK 
Sat Sep 17 11:27:18.917 2016 right Offset command failed for LUCIFER, pseudo-monocular passive, Sound=offsetFailed.wav 
Sat Sep 17 11:27:19.048 2016 both BinocularControl command started for LUCIFER with flag RELEASESYNCOFFSET 
Sat Sep 17 11:27:21.656 2016 both BinocularControl command complete for LUCIFER with flag RELEASESYNCOFFSET 
Sat Sep 17 11:27:22.098 2016 left Offset alert for LUCIFER: Pause{FLAO}[126] 
Sat Sep 17 11:27:22.112 2016 left Offset alert for LUCIFER: PCS OffsetTelescopeDETXY SYNCHRONIZED OffsetTelescope aborted on side left. 
Sat Sep 17 11:27:22.127 2016 left Offset alert for LUCIFER: PCS OffsetTelescopeDETXY failed on side left. 
Sat Sep 17 11:27:22.141 2016 left Offset command failed for LUCIFER, pseudo-monocular active, Sound=offsetFailed.wav 

11:37 Offset failed
  • Too much Tip on Resume and caused Safe Skip
Sat Sep 17 11:37:45.008 2016 left Offset command started for LUCIFER
Sat Sep 17 11:37:46.067 2016 left Offset alert for LUCIFER: Pause{FLAO}[126] - Illegal command for state AOArbitrator.Ready
Sat Sep 17 11:37:46.088 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav

11:43 Preset failed
  • TV viewer problem
  • But TV is Live
  • Set binning
Sat Sep 17 11:43:19.599 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[185]
Sat Sep 17 11:43:19.612 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[186] - [AOException] presetAO: FATAL - Attaching to shared buffer mirrorctrl.L:TECHVIEWER_65536 (-3508) SLOT_NOT_FOUND_ERROR
Sat Sep 17 11:43:19.626 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, Sound=presetFailed.wav

11:46 Preset failed due to TV Viewer
Sat Sep 17 11:46:11.627 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[187]
Sat Sep 17 11:46:11.637 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[188] - [AOException] presetAO: FATAL - Attaching to shared buffer mirrorctrl.L:TECHVIEWER_65536 (-3508) SLOT_NOT_FOUND_ERROR
Sat Sep 17 11:46:11.651 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, Sound=presetFailed.wav

* Stop/Start CCFD47 process
ccd47.L            |FAT|      2222|2016-09-17 11:46:26.876379|             MAIN > ccd47.L terminated by sysprocesses.L00
ccd47.L            |WAR|       239|2016-09-17 11:46:32.004984|             MAIN > [Config_File_Exception] Trying to access a non existing key: numDefaultBinBlack. To add a new element, use insert(string,Conf_Value) instead
  • Set binning
  • Failed
  • Power cycle 47 Little Joe, stop start 11:56 Preset Failed
pyarg              |ERR|      3293|2016-09-17 11:56:47.402251|             MAIN > Attaching to shared buffer mirrorctrl.L:TECHVIEWER_65536 (-3508) SLOT_NOT_FOUND_ERROR

12:01 Power off WUnit and power on to reset CCD47 12:08 Preset
  • SX failed because Gopt variable not available
Sat Sep 17 12:10:26.421 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: Stop{FLAO}[195]
Sat Sep 17 12:10:26.434 2016 left Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[196] - [AOException] presetAO: FATAL - thGetVar gopt.L.GOPT.REQ error(-3006): Variable not found error
Sat Sep 17 12:10:26.466 2016 left Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, Sound=presetFailed.wav

12:11 IDL Preset: Success

12:13 IDL RunAO: Success

12:18-12:50 Execute two Dice5 Scripts wit
  • Ghost in images seen in HeI/J filters (~40,000 count) LUCI 136-160ish
  • Ghosts not seen in HeI/Z or OH1060/Z (~1000 counts)

12:46 PauseAO error
  • In offset
  • CCD39 goes to Not Live
Sat Sep 17 12:46:37.189 2016 left Offset alert for LUCIFER: Resume{FLAO}[126] - [AOException] Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
Sat Sep 17 12:46:37.203 2016 left Offset alert for LUCIFER: Resume{FLAO}[126] - [AOException] Reading shared buffer masterdiagnostic.L:OPTLOOPBUF (-5001) TIMEOUT_ERROR
Sat Sep 17 12:46:37.217 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav
  • Stop/Start Slope computer, change binning, Not Live
  • Stop/Start Slope computer, CCD39 control and cycle power. Turn on in reverse order. Success