02:11 Load Programs fail at Horizon
  • idlctrl.L |INF| 2802|2016-09-16 02:11:48.030521| MAIN > 394:00265601um;
  • Load OK at Zenith

20:10 Bayside X not homing.
  • move rotator by 90 degrees
  • Homed fine

02:44 DX Preset fail
Fri Sep 16 02:44:49.518 2016 right Preset alert for LUCIFER mode ADAPTIVEACE_ACTIVE: PresetAO{FLAO}[15] - IDL variable undefined 'tn'
Fri Sep 16 02:44:49.533 2016 right Preset command failed for LUCIFER mode ADAPTIVEACE_ACTIVE with guidestars, AO reference, Sound=presetFailed.wav
  • on AOeng account, sudo mount -a

02:44 DX RunAO failed
Fri Sep 16 03:02:00.506 2016 right RunAO alert for LUCIFER: AcquireRef{FLAO}[18] - IDL variable undefined 'nstars'
Fri Sep 16 03:02:00.516 2016 right RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

03:10 DX RunAO failed
Fri Sep 16 03:15:54.764 2016 right RunAO alert for LUCIFER: AcquireRef{FLAO}[22] - Command timeout - -13107: Arbitrator interface generic error
Fri Sep 16 03:15:54.774 2016 right RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

WfsArbitrator_1409 |INF|       284|2016-09-16 03:41:36.456321|             MAIN > Starting gain optimization procedure
WfsArbitrator_1409 |ERR|       285|2016-09-16 03:44:10.774771|             MAIN > Traceback (most recent call last):
WfsArbitrator_1409 |ERR|       286|2016-09-16 03:44:10.774825|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2993, in arbFunc
WfsArbitrator_1409 |ERR|       287|2016-09-16 03:44:10.774858|             MAIN >     errstr = func(*args)
WfsArbitrator_1409 |ERR|       288|2016-09-16 03:44:10.774887|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2132, in optimizeGainInternal
WfsArbitrator_1409 |ERR|       289|2016-09-16 03:44:10.774915|             MAIN >     a.doit( app.ccd39.xbin())
WfsArbitrator_1409 |ERR|       290|2016-09-16 03:44:10.774945|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/autogain.py", line 310, in doit
WfsArbitrator_1409 |ERR|       291|2016-09-16 03:44:10.774977|             MAIN >     f, tt, ho1, ho2 = self.optimize( 'step-1218642828'2173088atastep, tt, ho1, ho2, start, end, step, cycles, gmin, ratio, target='all', set=True, middle_ho=ho_middle)
WfsArbitrator_1409 |ERR|       292|2016-09-16 03:44:10.775007|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/autogain.py", line 242, in optimize
WfsArbitrator_1409 |ERR|       293|2016-09-16 03:44:10.775039|             MAIN >     self.app.IDLCmd(cmd)
WfsArbitrator_1409 |ERR|       294|2016-09-16 03:44:10.775068|             MAIN >   File "/home/aoacct/aoroot/lib/python/AdOpt/thAOApp.py", line 625, in IDLCmd
WfsArbitrator_1409 |ERR|       295|2016-09-16 03:44:10.775096|             MAIN >   File "/home/aoacct/aoroot/lib/python/AdOpt/thAOApp.py", line 334, in SendMsg
WfsArbitrator_1409 |ERR|       296|2016-09-16 03:44:10.775125|             MAIN > error: thSendMessage error(-3606): No connection with MsgD
WfsArbitrator_1409 |DEB|       297|2016-09-16 03:44:10.775986|             MAIN > arbFunc doStopLoop (, 'FLAOWFS', 'LUCIFER')
WfsArbitrator_1409 |ERR|       298|2016-09-16 03:44:10.783113|             MAIN > Traceback (most recent call last):
WfsArbitrator_1409 |ERR|       299|2016-09-16 03:44:10.783150|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2993, in arbFunc
WfsArbitrator_1409 |ERR|       300|2016-09-16 03:44:10.783177|             MAIN >     errstr = func(*args)
WfsArbitrator_1409 |ERR|       301|2016-09-16 03:44:10.783203|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2212, in doStopLoop
WfsArbitrator_1409 |ERR|       302|2016-09-16 03:44:10.783247|             MAIN >     app.sc.fl_stop()
WfsArbitrator_1409 |ERR|       303|2016-09-16 03:44:10.783274|             MAIN >   File "/home/aoacct/aoroot/lib/python/AdOpt/hwctrl/slopecomp.py", line 88, in fl_stop
WfsArbitrator_1409 |ERR|       304|2016-09-16 03:44:10.783300|             MAIN >   File "/home/aoacct/aoroot/lib/python/AdOpt/thAOApp.py", line 359, in WriteVar
WfsArbitrator_1409 |ERR|       305|2016-09-16 03:44:10.783327|             MAIN > error: thWriteVar error(-2010): Connection closed at the other end

03:11 CLosed loo on SX. No safe skip while doing Optimize gain

03:24 Safe Skip, Loop Open
adsecarb.L         |WAR|       511|2016-09-16 03:24:12.172389|             MAIN > Skip frame detected!
adsec.L            |INF|      2871|2016-09-16 03:24:11.515410|             MAIN > fsm_stop_ao start
adsec.L            |INF|      2872|2016-09-16 03:24:11.515485|             MAIN > fsm_skip_recovery FORCE set
adsec.L            |INF|      2873|2016-09-16 03:24:11.744374|             MAIN > Null Gain application and start sending null slope...
adsec.L            |INF|      2874|2016-09-16 03:24:11.891245|             MAIN > Cleaned last slopes command.
adsec.L            |INF|      2875|2016-09-16 03:24:11.891333|             MAIN > Modes out of safe range    ID: # -1
adsec.L            |INF|      2876|2016-09-16 03:24:11.891413|             MAIN > Commands out of safe range ID: # -1
adsec.L            |INF|      2877|2016-09-16 03:24:11.891524|             MAIN > Forces out of safe range   ID: # 11
adsec.L            |INF|      2878|2016-09-16 03:24:11.891574|             MAIN > SafeSkipFrames caused by forces out of range detected.
adsec.L            |INF|      2879|2016-09-16 03:24:11.891619|             MAIN > Recovery from any SafeSkipFrames started...

03:53 Funny offset error. I think it is from the Active Optics
IDL> iif_offset, /left
  
      IRCL: offset, 45, 5, ROT=0, COORD=DETXY, MOVE=ABS     (iif_offset)
  
  => Warning in irc_offsetpointing
        msg = Resmsg[0]  = OffsetPointing2 result status: Warning
        msg = Resmsg[1]  = Pause{FLAO}[24]
        msg = Resmsg[2]  = WFS loop is not paused
        msg = Resmsg[3]  = OffsetXY{FLAO}[45]
        msg = Resmsg[4]  = Resume{FLAO}[24]
IDL> 

Fri Sep 16 03:53:35.311 2016 left Offset alert for LUCIFER: Pause{FLAO}[24]
Fri Sep 16 03:53:35.320 2016 left Offset alert for LUCIFER: WFS loop is not paused
Fri Sep 16 03:53:35.336 2016 left Offset alert for LUCIFER: OffsetXY{FLAO}[45]
Fri Sep 16 03:53:35.350 2016 left Offset alert for LUCIFER: Resume{FLAO}[24]
Fri Sep 16 03:53:35.364 2016 left Offset command complete with warnings for LUCIFER, S

03:58 Loop open because of Safe Skip after an offset of -45, 0.
  • Star was not positioned on pyramid very well.
  • Loop closed and a lot of tip put on mirror.
  • Not offload fast enough
  • Safe Skip
  • Loop Open
Fri Sep 16 03:58:32.507 2016 left AO loop state has changed from Closed to Open

04:30 Start CentOS 6 on SX
  • Power on and Load no problems
  • Error When try to SetFlat.
  • Elevation on AdSec Control GUI is 89 degrees
adsecarb.L         |INF|       108|2016-09-16 04:28:45.977009|   COMMANDHANDLER > FSM (status: Ready) has received command 2009 (Set Flat AO)
adsecarb.L         |INF|       109|2016-09-16 04:28:45.977387|   COMMANDHANDLER > Command not executed (status RETRY) (errstr Elevation value below threshold! Cannot set shell)
20161609 04:28:54.3931 Alert: HighOrderOffload: HighOrderOffload vector ready
adsec.L            |INF|       435|2016-09-16 04:29:36.594911|             MAIN > fsm_set_flat() procedure started.
adsec.L            |ERR|       436|2016-09-16 04:29:36.703975|             MAIN > Found misfunctioning capacitive sensors
20161609 04:29:36.7049 Alert: Warning: setFlatAo failed or syntax error occured
adsecarb.L         |ERR|       104|2016-09-16 04:29:36.704557|              IDL > Command returns error : IDL An in-use actuator used is not working anymore
adsecarb.L         |INF|       105|2016-09-16 04:29:36.704689|   COMMANDHANDLER > Command execution failed: Fsm forced to Failure
adsec.L            |ERR|       437|2016-09-16 04:29:36.704057|             MAIN > 426:00269044um;
  • adsc_stop, start
  • Power on, Load, Set OK

04:35 Move to lower star. Was at 88 elevation

06:20 Closes the loop in intervention mode.
  • Skip Optimize gain and set gains by hand
  • Stop

06:41 iif_offset, 0, 5 * failed with ICE exception
Fri Sep 16 06:41:13.750 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 06:41:13.764 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 06:41:13.793 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav
  • AdSec Arb died. Restarted
  • Loop was still Running
  • AOS reports LoopSuspended
  • Tried:
    • iif_runao, TYPE=SKIPALL, /LEFT
Fri Sep 16 06:44:25.233 2016 left RunAO command started from LUCIFER, type SKIPALL, leftRePoint 0, rightRePoint 0
Fri Sep 16 06:44:25.243 2016 left RunAO alert for LUCIFER: AO loop already closed
Fri Sep 16 06:44:25.257 2016 left RunAO command complete with warnings for LUCIFER, type SKIPALL, leftRePoint 0, rightRePoint 0

07:05 iif_offset, 5, 5
  • Failed
Fri Sep 16 07:05:16.718 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [AOException] RETRY: Magnitude calculation cannot take place with negative counts (-5002) VALUE_OUT_OF_RANGE_ERROR
Fri Sep 16 07:05:16.732 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [AOException] RETRY: Magnitude calculation cannot take place with negative counts (-5002) VALUE_OUT_OF_RANGE_ERROR
Fri Sep 16 07:05:16.747 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav
  • Loop is still running
  • StopAO from AOS Command GUI
    • failed
Fri Sep 16 07:06:50.837 2016 aos.Stop{FLAO}.failed - Stop{FLAO}[57] - [Exception] Ice.ConnectionRefusedException:Connection refused

07:31 iif_offset, 5,5
  • Failed
Fri Sep 16 07:31:49.877 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [AOException] RETRY: Magnitude calculation cannot take place with negative counts (-5002) VALUE_OUT_OF_RANGE_ERROR
Fri Sep 16 07:31:49.892 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [AOException] RETRY: Magnitude calculation cannot take place with negative counts (-5002) VALUE_OUT_OF_RANGE_ERROR
Fri Sep 16 07:31:49.907 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav

07:37 RunAO
  • press Cancel Preset on FLAO GUI
Fri Sep 16 07:37:15.945 2016 left RunAO alert for LUCIFER: StartAO{FLAO}[77] - Illegal command for state AOArbitrator.Ready
Fri Sep 16 07:37:15.961 2016 left RunAO alert for LUCIFER: StartAO{FLAO}[77] - Illegal command for state AOArbitrator.Ready
Fri Sep 16 07:37:15.976 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

07:37 Send RunAO (without a preset)
  • failed immediately
2016 left RunAO command started from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
Fri Sep 16 07:37:44.610 2016 right RunAO command started from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
Fri Sep 16 07:37:44.957 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[78] - Illegal command for state AOArbitrator.Ready
Fri Sep 16 07:37:44.966 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

08:21 iif_offset, 5, 0
  • failed
  • adsec arbitrator died
  • Loop still running
  • restart adsec arb. no problems. still loop closed
Fri Sep 16 08:21:03.898 2016 left Offset alert for LUCIFER: Pause{FLAO}[24] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 08:21:03.908 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav

08:24 iif_offset, 5,0
  • failed
  • Loop left in Pause on Adsec
  • Loop left in LoopClosed on WFS
Fri Sep 16 08:24:23.616 2016 left Offset command started for LUCIFER
Fri Sep 16 08:24:26.320 2016 left Offset alert for LUCIFER: Pause{FLAO}[24] - FLAO: unknown exception from arbitrator
Fri Sep 16 08:24:26.337 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav
  • Open, Resume, Pause and Close buttons on WFS Control GUI are not available
  • From AOS Command GUI, Resume and Stop Both fail
  • Gopt loop in not running. Data is saved, but in gopt log see 0/0
  • stop wfsarb
    • running but not connected to msgd
    • kill -9 wfsarb
    • wfs control gui now have Open, Resume, ect
  • Open on wfs control gui
  • Send preset, OK

08:34 Bayside X timeout. First one this Fall
Fri Sep 16 08:34:43.333 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[106] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Fri Sep 16 08:34:43.350 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

0
baysidex.L         |INF|       190|2016-09-16 08:34:33.246371|             MAIN > Moving to: -76.603 mm
baysidex.L         |INF|       191|2016-09-16 08:34:33.732715|             MAIN > Stage pos (mm): -77.205, current (A): 1.540
baysidex.L         |INF|       192|2016-09-16 08:34:34.093089|             MAIN > Stage pos (mm): -76.699, current (A): 1.880
baysidex.L         |INF|       193|2016-09-16 08:34:34.417291|             MAIN > Stage pos (mm): -76.640, current (A): 2.010
baysidex.L         |INF|       194|2016-09-16 08:34:34.741504|             MAIN > Stage pos (mm): -76.589, current (A): 1.870
baysidex.L         |INF|       195|2016-09-16 08:34:35.054982|             MAIN > Stage pos (mm): -76.588, current (A): 1.790
baysidex.L         |INF|       196|2016-09-16 08:34:35.367470|             MAIN > Stage pos (mm): -76.588, current (A): 1.730
  • but HW gui shows baysidex at -76.603
  • on the HW gui I moved the stage
  • next preset the stage moved

08:56 RunAO bayside X timeout
Fri Sep 16 08:56:05.034 2016 left RunAO command started from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
Fri Sep 16 08:56:19.830 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[113] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Fri Sep 16 08:56:19.839 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

09:06 offset failed because X flip is wrong
  • X stage move the wrong way
  • edit file
    • /home/flao/TEST/conf/wfs/current/processConf/wfsarb.conf
    • change flipX int 0 -to- 1
  • Still not work

09:50 Alfio fix bug in WFS arbitrator
  • Now offsets work
  • Tested in X and Y

10:05 Test off-axis presets
  • -Y worked
  • -X worked

10:38 Opt Loop Data
  • 103835

10:45 offset Fail
Fri Sep 16 10:45:31.234 2016 left Offset alert for LUCIFER: OffsetXY{FLAO}[194]
Fri Sep 16 10:45:31.265 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 10:45:31.295 2016 left Offset alert for LUCIFER: Resume{FLAO}[24] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 10:45:31.329 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav

10:59 Loop Open
  • Safe Skip
  • Loop Open
  • AdSec Arbitrator Die
adsecarb.L         |WAR|       352|2016-09-16 10:59:09.656612|             MAIN > Skip frame detected!
adsecarb.L         |INF|       353|2016-09-16 10:59:09.776545|             MAIN > Received cmd: StopAo(1)
adsecarb.L         |INF|       354|2016-09-16 10:59:09.776611|   COMMANDHANDLER > FSM (status: AORunning) has received command 2015 (Stop Ao)
adsecarb.L         |ERR|       355|2016-09-16 10:59:09.776632|   COMMANDHANDLER > adsecarb: Fsm is discarding command 2015 (Stop Ao)...
adsecarb.L         |WAR|       356|2016-09-16 10:59:09.776684|             MAIN > StopAo: WARNING - adsecarb:Illegal command for state AORunning (Stop Ao)
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN > Cannot dispatch alert: Outgoing.cpp:493: Ice::UnknownException:
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  . unknown exception:
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  . Traceback (most recent call last):
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .   File "aoarbitrator.py", line 184, in alert
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .     self._loop._fsm.SkfAlert()
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .   File "/home/aoeng/aoroot/lib/python/AOArb_sm.py", line 597, in trans_sm
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .     getattr(self.getState(), attrib)(self, *arglist)
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .   File "/home/aoeng/aoroot/lib/python/AOArb_sm.py", line 444, in SkfAlert
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .     AOArbitrator_Default.SkfAlert(self, fsm)
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .   File "/home/aoeng/aoroot/lib/python/AOArb_sm.py", line 78, in SkfAlert
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .     self.Default(fsm)
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .   File "/home/aoeng/aoroot/lib/python/AOArb_sm.py", line 89, in Default
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  .     raise statemap.TransitionUndefinedException(msg)
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  . TransitionUndefinedException: 
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  . 	State: AOArbitrator.LoopClosed
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  . 	Transition: SkfAlert
adsecarb.L         |WAR|       357|2016-09-16 10:59:09.777461|             MAIN >  . 

11:08 RunAO failed with baysidex timeout
Fri Sep 16 11:08:25.125 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[200] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Fri Sep 16 11:08:25.154 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

11:15 RunAO failed because the Optical Gain process was running
Fri Sep 16 11:15:50.037 2016 right AO loop state has changed from Open to Closed
Fri Sep 16 11:16:06.486 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[203] - [Exception] Ice.ConnectionLostException:Connection reset by peer
Fri Sep 16 11:16:06.537 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

11:38 Offset fail
Fri Sep 16 11:36:41.263 2016 left Offset command started for LUCIFER
Fri Sep 16 11:36:43.235 2016 right Offset alert for LUCIFER: Pause{FLAO}[12] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 11:36:43.258 2016 right Offset command failed for LUCIFER, Sound=offsetFailed.wav

11:43 RunAO failed with bayside timeout
Fri Sep 16 11:43:52.071 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[217] - [AOException] centerStar: FATAL - Timeout error on baysidex (-5001) TIMEOUT_ERROR
Fri Sep 16 11:43:52.081 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

Fri Sep 16 11:59:23.204 2016 left Offset alert for LUCIFER: Pause{FLAO}[24] - [Exception] Ice.ConnectionRefusedException:Connection refused
Fri Sep 16 11:59:23.223 2016 left Offset command failed for LUCIFER, Sound=offsetFailed.wav

12:31 Bad actuator found during SetFlat
adsec.L            |ERR|      3152|2016-09-16 12:31:10.662254|             MAIN > Found misfunctioning capacitive sensors
adsec.L            |ERR|      3153|2016-09-16 12:31:10.662369|             MAIN > 493:00265465um;
20161609 12:31:10.6632 Alert: Warning: setFlatAo failed or syntax error occured
adsecarb.L         |ERR|       206|2016-09-16 12:31:10.662844|              IDL > Command returns error : IDL An in-use actuator used is not working anymore
adsecarb.L         |INF|       207|2016-09-16 12:31:10.662975|   COMMANDHANDLER > Command execution failed: Fsm forced to Failure
adsecarb.L         |ERR|       208|2016-09-16 12:31:10.663050|             MAIN > SetFlatAo: FATAL - IDL An in-use actuator used is not working anymore

12:41 bad actuator 069

12:43 AOS patch
  • Button are correct now
  • Powered ON from AOS: Success
  • SET from AOS: Success
  • REST from AOS: Success