Title

04:00 Closed loop on SX with ARGOS CalUnit

04:23 Opt Gain
  • 0.97, 0.17, 0.17
  • NCPA Z4-11 -30, -18, -6, 4, 13, 9, -14, 0

05:03 NCPA Measurements
  • Centered spot
  • 128x128 subframe

05:05 Rot = 360
  • NCPA Z4-11 -30, -18, -6, 4, 13, 9, -14, 0
  • Z4 from -50-0
  • Error when trying to calculate
Saved tracknum:  
Mode 4: 0
M2C name: /home/flao/TEST//calib//adsec/current/M2C/KL_v20/m2c.fits
Saved tracknum:  
% Compiled module: MERIT_NCPA.
% Compiled module: AO_INIT.
% AO_INIT: WARNING: PHASEMAPDIR not initialized.
% Compiled module: GETAOELAB.
% Unable to invoke method on NULL object reference: )>.
% Execution halted at: MERIT_NCPA         11 /home/flao/TEST/idl/wfs_lib/merit_ncpa.pro
%                      $MAIN$          
IDL variable undefined 'result'
Traceback (most recent call last):
  File "/home/flao/TEST/bin/luci_ncpa.py", line 210, in ?
    best[mode] = analyse( self, tracknums, amps)
  File "/home/flao/TEST/bin/luci_ncpa.py", line 148, in analyse
    sr[i] = analyse_single2( app, tracknums[i])
ValueError: setting an array element with a sequence.
[flao@wfssx bin]$ 
  • forgot to get Dark. Will try again

05:14 Collect 20 darks from WFS GUI
  • Error

WfsArbitrator_28924|INF|       509|2016-09-14 05:14:27.097570|             MAIN > calibIRTCDarkInternal(): starting measure, 20 frames
WfsArbitrator_28924|DEB|       510|2016-09-14 05:14:40.040038|             MAIN > getSetupFits(): fits header created
WfsArbitrator_28924|ERR|       511|2016-09-14 05:14:40.057460|             MAIN > Traceback (most recent call last):
WfsArbitrator_28924|ERR|       512|2016-09-14 05:14:40.057491|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2993, in arbFunc
WfsArbitrator_28924|ERR|       513|2016-09-14 05:14:40.057531|             MAIN >     errstr = func(*args)
WfsArbitrator_28924|ERR|       514|2016-09-14 05:14:40.057551|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2519, in calibIRTCDarkInternal
WfsArbitrator_28924|ERR|       515|2016-09-14 05:14:40.057570|             MAIN >     filename = saveCalibFile( app, calib.BackgDir(ccd, 1), frame, IrtcHdr, ensureExtension( app, name, '.fits'), getFullPath = True)
WfsArbitrator_28924|ERR|       516|2016-09-14 05:14:40.057588|             MAIN >   File "/home/flao/TEST/lib/python/AdOpt/WfsArbScripts.py", line 2560, in saveCalibFile
WfsArbitrator_28924|ERR|       517|2016-09-14 05:14:40.057607|             MAIN >     fits_lib.writeSimpleFits( filename, data, hdr)
WfsArbitrator_28924|ERR|       518|2016-09-14 05:14:40.057625|             MAIN >   File "/home/aoacct/aoroot/lib/python/AdOpt/fits_lib.py", line 83, in writeSimpleFits
WfsArbitrator_28924|ERR|       519|2016-09-14 05:14:40.057644|             MAIN >   File "/home/aoacct/aoroot/lib/python/AdOpt/fits_lib.py", line 49, in addToFits
WfsArbitrator_28924|ERR|       520|2016-09-14 05:14:40.057663|             MAIN >   File "/usr/lib/python2.4/site-packages/pyfits/NP_pyfits.py", line 1068, in update
WfsArbitrator_28924|ERR|       521|2016-09-14 05:14:40.057682|             MAIN >     self.ascard.append(Card(key, value, comment))
WfsArbitrator_28924|ERR|       522|2016-09-14 05:14:40.057700|             MAIN >   File "/usr/lib/python2.4/site-packages/pyfits/NP_pyfits.py", line 1291, in append
WfsArbitrator_28924|ERR|       523|2016-09-14 05:14:40.057719|             MAIN >     self._use_blanks(card._ncards())
WfsArbitrator_28924|ERR|       524|2016-09-14 05:14:40.057738|             MAIN >   File "/usr/lib/python2.4/site-packages/pyfits/NP_pyfits.py", line 759, in _ncards
WfsArbitrator_28924|ERR|       525|2016-09-14 05:14:40.057756|             MAIN >     return len(self._cardimage) / Card.length
WfsArbitrator_28924|ERR|       526|2016-09-14 05:14:40.057775|             MAIN >   File "/usr/lib/python2.4/site-packages/pyfits/NP_pyfits.py", line 338, in __getattr__
WfsArbitrator_28924|ERR|       527|2016-09-14 05:14:40.057793|             MAIN >     self.ascardimage()
WfsArbitrator_28924|ERR|       528|2016-09-14 05:14:40.057812|             MAIN >   File "/usr/lib/python2.4/site-packages/pyfits/NP_pyfits.py", line 415, in ascardimage
WfsArbitrator_28924|ERR|       529|2016-09-14 05:14:40.057830|             MAIN >     self._ascardimage()
WfsArbitrator_28924|ERR|       530|2016-09-14 05:14:40.057849|             MAIN >   File "/usr/lib/python2.4/site-packages/pyfits/NP_pyfits.py", line 500, in _ascardimage
WfsArbitrator_28924|ERR|       531|2016-09-14 05:14:40.057868|             MAIN >     raise ValueError, "The keyword  with its value is too long." Kelf.key
WfsArbitrator_28924|ERR|       532|2016-09-14 05:14:40.057887|             MAIN > ValueError: The keyword LBTO LUCI DET OS with its value is too long.

06:05 Opt Loop Data
  • 060523

06:30 Tried to delete the offending header keyword. Failed

06:45 Start CentOS 6 on SX side to check saving of Optical Loop Data (that is failing on DX CentOS 7 side)
  • Closed Loop
  • Gopt working
  • Save Opt. Loop Date successfully
  • 071102
  • Low gains, 0.25, 0.5, 0.5 set by hand
  • optimize gain

07:15:28 Error during optimize gain box pop up, but no errors listed
  • wfsarb is running but not connected to the msgd
  • kill - 9 process
  • start wfsarb from GUI
  • Loop still running
  • Click Close on wfs Control GUI
  • Loop Open

07:20 Closed loop
  • optimize gain
  • no Gopt
  • Opt loop data 072530
  • modal_plot_072530:
    modal_072530.jpg

07:29 Opt Loop Data
  • Gopt on
  • 072950

07:35 Run IDL
  • AO> a = getaoelab('20160914_072530')
  • Error
    • % AOPUPILS::INIT: File not found:/local/aomeas/wfs_calib_W1/ccd39/LUTs/bin1/20160209-190618/pup1.fits
  • where are the pupil? Is this why the modal plot is bad?

07:45 Try to Acquire PISCES dark
  • failed
  • pyarg |INF| 686|2016-09-14 07:46:32.197179| MAIN > calibIRTCDarkInternal(): starting measure, 20 frames
  • pyarg |ERR| 687|2016-09-14 07:46:32.252964| MAIN > RETRY: Error reading LUCI (0) NO_ERROR
  • Request was for LUCI2 image not LUCI1
    • /bin/sh /home/lucifer/lcsp/bin/commitReadout.sh wait pause 0 20 2
  • Need to fix the sidedness of the request. Alfio?

08:51 Can not see binning buttons on CentOS 6 CCD39 or 47 HW GUIs
  • Displayed on CentOS 6 machine in remote room
  • Greg could see the buttons on his laptop displaying the WFS HW GUI
  • Binning Buttons:
    binning_buttons.jpg

-- %USERSIG{DougMiller - 2016-09-14}%
I Attachment Action Size Date Who Comment
binning_buttons.jpgjpg binning_buttons.jpg manage 34 K 14 Sep 2016 - 08:52 DougMiller Binning Buttons
modal_072530.jpgjpg modal_072530.jpg manage 48 K 14 Sep 2016 - 07:31 DougMiller modal_plot_072530
Topic revision: r3 - 14 Sep 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback