Title

adsec.R            |INF|       444|2016-09-13 01:39:35.489318|             MAIN > Update progress successfully completed (2)
20161309 01:39:35.7289 Alert: Warning: loadProgram failed or syntax error occured
adsecarb.R         |ERR|       103|2016-09-13 01:39:35.728371|              IDL > Command returns error : IDL Dust detected in the mirror
adsecarb.R         |INF|       104|2016-09-13 01:39:35.728863|   COMMANDHANDLER > Command execution failed: Fsm forced to Failure
adsec.R            |INF|       445|2016-09-13 01:39:35.725157|             MAIN > No misfunctioning capacitive sensors found.
adsec.R            |ERR|       446|2016-09-13 01:39:35.726305|             MAIN > Found possible gap contamination
adsec.R            |ERR|       447|2016-09-13 01:39:35.726407|             MAIN > 448:059um;449:060um;450:060um;

mpSaved vector ready
adsec.R            |ERR|       727|2016-09-13 02:14:31.544643|             MAIN > Found misfunctioning capacitive sensors
adsec.R            |ERR|       728|2016-09-13 02:14:31.544742|             MAIN > 467:00257053um;479:00000154um;
adsecarb.R         |ERR|       113|2016-09-13 02:14:31.545684|              IDL > Command returns error : IDL An in-use actuator used is not working anymore
adsecarb.R         |INF|       114|2016-09-13 02:14

|             MAIN > Reference wave decreased
adsec.R            |ERR|      1005|2016-09-13 02:20:09.005773|             MAIN > Found misfunctioning capacitive sensors
adsec.R            |ERR|      1006|2016-09-13 02:20:09.005840|             MAIN > 467:00257053um;
adsecarb.R         |ERR|       125|2016-09-13 02:20:09.006868|              IDL > Command returns error : IDL An in-use actuator used is not working anymore
adsecarb.R         |INF|       126|2016-09-13 02:20:09.007112|   COMMANDHANDLER > Command execution failed: Fsm forced to Failure

NCPA Test with CentOS 5 on SX

05:00 Power on WFS

05:30 Find ARGOS Cal Source

05:35 SX Hexapod 4.5, 3.1, -0.68 -177 37

05:40 Closed loop
  • Optimize Gain
    • 1.7, 0.67, 0.17
  • 9.3 mag
  • Opt Loop Data 055413
  • Oops, 99 Hz
  • Click Loop Params Apply again, after open loop: OK
  • Acquire HO dark

05:57 Closed Loop
  • Bin 1
  • 990 Hz
  • 3 lam/D
  • Let Cameral Lens align
  • Turn off Cam Lens
  • Optimize Gain
    • 0.88, 0.17, 0.17
  • Sync WFS
  • Ooops, Rerotator was off

06:03 Save Opt Loop Data
  • gain 0.88, 0.17, 0.17, Gopt Off
    • 060323
  • gain 0.44, 0.08, 0.08, Gopt Off = 0.50
    • 060513

06:06 Closed Loop with Rerotator on
  • gain 0.93, 0.17, 017 (same as before)

06:09 NCPA Applied
  • Rot = 341
  • NCPA Z4-11 = -17, -16, -2, 6.5, 11, -3, -11.4 -2.5
  • 061100

06:39 Closed Loop
  • Rot 360
  • Z4-11 -30, -18, -6, 4, 13, 9, -14, 0

-- %USERSIG{DougMiller - 2016-09-13}%

Comments

 
Topic revision: r2 - 13 Sep 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.