Closed Dome Testing on DX

03:20 Stop processes on flao@wfsdx with w_stop

03:22 Start processes on AOeng@ao-wfsdx2 with w_start
  • work fine

03:24 run wfshw.py
  • get py error
  • Xianyu work on it

04:30 Wind lower, open

04:51 LUCI send ACE preset on both sides

04:57 Bayside Y error
  • WfsArbitrator_2071 |ERR| 360|2016-04-24 04:57:42.692293| MAIN > AdOptError: Timeout waiting for baysidey.L.ENABLE.CUR - code: -5001 TIMEOUT_ERROR
  • WfsArbitrator_2071 |ERR| 450|2016-04-24 05:00:50.795753| MAIN > AdOptError: Timeout waiting for baysidey.L.ENABLE.CUR - code: -5001 TIMEOUT_ERRO
  • SX Rotator Angle = 226 degrees

05:20
  • Sun Apr 24 05:20:16.097 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[284]
  • Sun Apr 24 05:20:16.124 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

05:45 Closed
  • Wind gusts to 22.5 m/s
  • Clouds forming above us
  • Humidity 80%
  • Seeing 1.2" to 1.9"
  • Can not keep the loops closed, skip frames

08:42 Open as wind go below 20 m/s

09:00 Strange images on DX GCS
  • 1/3 the flux of SX
  • terrible collimation. Kind of looks like Coma, but kind of not
  • Rested and Set the shell (@ 75 el) only 170 modes used
  • DX Bad ouf of focus image:
    DX_bad_iq_2.jpg
  • Look at M2, M3 and front of AGW. Nothing obvious.

10:30 Open again and DX collimation is fine.
  • When we closed we Rested the shell
  • When opened, Steve Set the shell at 90 el. 260 modes used