LUCI1/AO Commissioning

02:00 Telescope Open

02:20 Getting many SX AdSec emails. disk is full

02:42 Jochen send preset

02:42 AOARB.L |ERR| 96|2016-04-23 02:42:45.378020| SERIALIZATION > Error in message deserialization from AOS.L (014000/2012)

02:48 Resend preset
  • AOARB.L |ERR| 102|2016-04-23 02:48:05.124458| SERIALIZATION > Error in message deserialization from AOS.L (014000/2009)

02:50 click PresetAO form Command GUI. Same error

02:52 Stop and restart AOARB and AOS left

03:04 LUCI1 timed out on RunAO because the autogain took 10 minutes. This is a timeout in LUCI SW
  • Second time it did not take as long so success
  • Loop closed and LUCI continue

03:10 Modify autogain.conf
  • change bin4_cycles from 10 to 4
  • file /home/flao/TEST/conf/wfs/currrent/processConf/autogain.conf

06:00 to 09:20 Alfio and Enrico work on improved Gopt

09:29 Baysidey timeout
  • Sat Apr 23 09:29:35.853 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[170] - Timeout waiting for baysidey.L.ENABLE.CUR (-5001) TIMEOUT_ERROR
  • Sat Apr 23 09:29:35.862 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

09:47 Bin 3 Optical Loop Data
  • No Optical Gain loop
  • Auto gain 2.0, 2.0, 2.0
    • 094705
    • 094800
    • 094844
  • gain 3.0, 2.0, 2.0
    • 095022
    • 095057
    • 095130

09:54 Bin 4 Optical Loop Data
  • No Optical Gain loop
  • Auto gain 3.4, 0.7, 0.9
    • Failed putting star on tip of pyramid
      • Sat Apr 23 10:05:34.837 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[196] - RETRY: No stars found in TV frame (-20001) WFSARB_STAR_NOTFOUND
      • Sat Apr 23 10:05:34.847 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0
    • 102623
    • 102729
    • 102832

10:29 Hand back to LUCI

10:39 Baysidey timeout
  • Sat Apr 23 10:39:27.170 2016 left RunAO alert for LUCIFER: AcquireRef{FLAO}[219] - Timeout waiting for baysidey.L.ENABLE.CUR (-5001) TIMEOUT_ERROR
  • Sat Apr 23 10:39:27.182 2016 left RunAO command failed from LUCIFER, type NORMAL, leftRePoint 0, rightRePoint 0

-- %USERSIG{DougMiller - 2016-04-23}%
Topic revision: r4 - 23 Apr 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback