Title

19:23 Clicking HO1 gain down from 0.35 to 0.0 quickly and get this error.
idlctrl.R          |INF|      4691|2016-04-07 19:23:44.607276|             MAIN > Executing command: errcode= fsm_set_gain('/home/flao/TEST//calib//adsec/current/M2C/KL_v21/gain/g_tt_0.70_ho1_0.05_ho2_0.00.fits', BANK=0) & print, errcode
idlctrl.R          |INF|      4692|2016-04-07 19:23:44.607403|             MAIN > StartCmd
idlctrl.R          |INF|      4693|2016-04-07 19:23:44.621997|             MAIN >        0
idlctrl.R          |INF|      4693|2016-04-07 19:23:44.621997|             MAIN >  . EndCmd
idlctrl.R          |INF|      4694|2016-04-07 19:23:44.622033|             MAIN > % READFITS: Now reading 672 element array
idlctrl.R          |INF|      4694|2016-04-07 19:23:44.622033|             MAIN >  . 
idlctrl.R          |INF|      4695|2016-04-07 19:23:44.759746|             MAIN > Executing command: errcode= fsm_set_gain('/home/flao/TEST//calib//adsec/current/M2C/KL_v21/gain/g_tt_0.70_ho1_0.00_ho2_0.00.fits', BANK=0) & print, errcode
idlctrl.R          |INF|      4696|2016-04-07 19:23:44.759861|             MAIN > StartCmd
idlctrl.R          |INF|      4697|2016-04-07 19:23:44.764128|             MAIN >   -10023
idlctrl.R          |INF|      4698|2016-04-07 19:23:44.764165|             MAIN > % READFITS: Now reading 672 element array
idlctrl.R          |INF|      4698|2016-04-07 19:23:44.764165|             MAIN >  . % WRITE_SEQ_DSP:  Writing check failed
idlctrl.R          |INF|      4698|2016-04-07 19:23:44.764165|             MAIN >  . 
idlctrl.R          |INF|      4699|2016-04-07 19:23:44.764186|             MAIN > EndCmd

*NOTE* the file /home/flao/TEST//calib//adsec/current/M2C/KL_v21/gain/g_tt_0.70_ho1_0.00_ho2_0.00.fits is corrupt; cannot be read. The error that the file is not read should stop the change gain routine, but it looks like the corrupt values for gains are passed to the AdSec the result is the AdSec goes into a "Failure" state.
  • To get out of the Failure state:
    • Open the loop on the WFS Control GUI
    • Stop and start the AdSec Arbitrator
    • Shell is now Rested, so Set the shell

20:19 Can not get Gopt to run (Save data) Will restart
  • Hexapod -5.9 -7.8 0.83 121, 36
  • Bayside -75.2, -49.5, 56.5

21:37 Trouble getting the Gopt routine to run
  • start "Optical Gain" process from process gui
  • saves one file and then dies => see log output below
  |INF|      2738|2016-04-07 21:36:49.569000|             MAIN > Getting frame 1997 of 2000
od_gopt.R          |INF|      2739|2016-04-07 21:36:49.571098|             MAIN > Getting frame 1998 of 2000
od_gopt.R          |INF|      2740|2016-04-07 21:36:49.573248|             MAIN > Getting frame 1999 of 2000
od_gopt.R          |INF|      2741|2016-04-07 21:36:49.575392|             MAIN > Getting frame 2000 of 2000
od_gopt.R          |INF|      2742|2016-04-07 21:36:49.575485|             MAIN > Writing on disk....
od_gopt.R          |ERR|      2743|2016-04-07 21:36:49.576027|             MAIN > Error saving dimm data: (-1) Return from search routine (item not found)
od_gopt.R          |ERR|      2744|2016-04-07 21:36:49.576547|             MAIN > Error saving wind speed data: (-1) Return from search routine (item not found)
od_gopt.R          |ERR|      2745|2016-04-07 21:36:49.576903|             MAIN > Error saving wind direction data: (-1) Return from search routine (item not found)
od_gopt.R          |ERR|      2746|2016-04-07 21:36:49.577181|             MAIN > Error saving guide camera data: (-1) Return from search routine (item not found)
od_gopt.R          |ERR|      2747|2016-04-07 21:36:49.577444|             MAIN > Error saving slope data
od_gopt.R          |ERR|      2748|2016-04-07 21:36:49.577714|             MAIN > Error saving modes data
od_gopt.R          |ERR|      2749|2016-04-07 21:36:49.578058|             MAIN > Error saving frames counter data
od_gopt.R          |ERR|      2750|2016-04-07 21:36:49.578496|             MAIN > Error saving frames counter data
od_gopt.R          |ERR|      2751|2016-04-07 21:36:49.578793|             MAIN > Error saving command data
od_gopt.R          |ERR|      2752|2016-04-07 21:36:49.579081|             MAIN > Error saving skip frame counter data
od_gopt.R          |ERR|      2753|2016-04-07 21:36:49.579360|             MAIN > Error saving pending frame counter data
od_gopt.R          |ERR|      2754|2016-04-07 21:36:49.579646|             MAIN > Error saving wfs global timeout data
od_gopt.R          |ERR|      2755|2016-04-07 21:36:49.579932|             MAIN > Error saving fastlink timeout data
od_gopt.R          |ERR|      2756|2016-04-07 21:36:49.580530|             MAIN > Error saving crc errors data
od_gopt.R          |ERR|      2757|2016-04-07 21:36:49.580951|             MAIN > Error saving timestamp data
od_gopt.R          |ERR|      2758|2016-04-07 21:36:49.581228|             MAIN > Error saving loop closed data
od_gopt.R          |ERR|      2759|2016-04-07 21:36:49.581500|             MAIN > Error saving antidrift data
od_gopt.R          |INF|      2760|2016-04-07 21:36:49.582933|             MAIN > All data saved correctly

21:49 Try to start "Optical diag. for Gopt" process from system process gui and get in log:
  • When the process start the first time, did not get this error. On every subsequent try, get this error
od_gopt.R          |DEB|        20|2016-04-07 21:50:55.584324|    ARB-INTERFACE > My level is 7 (DEB)
od_gopt.R          |DEB|        21|2016-04-07 21:50:55.584340|    ARB-INTERFACE > SerializableMessageSender for succesfully created!
od_gopt.R          |INF|        22|2016-04-07 21:50:55.584352|    ARB-INTERFACE > ArbitratorInterface to wfsarb.R succesfully created!
od_gopt.R          |DEB|        23|2016-04-07 21:50:55.584369|    ARB-INTERFACE > My level is 7 (DEB)
od_gopt.R          |DEB|        24|2016-04-07 21:50:55.584380|    ARB-INTERFACE > SerializableMessageSender for succesfully created!
od_gopt.R          |INF|        25|2016-04-07 21:50:55.584391|    ARB-INTERFACE > ArbitratorInterface to adsecarb.R@M_ADSEC succesfully created!
od_gopt.R          |WAR|        26|2016-04-07 21:50:55.584444|     GET_RAW_DATA > Error reading shared buffer: This operation requires previous initialization - trying to reattach [AdsecDiagnLib.cpp:144

22:00 The DX loop was not stable
  • Could only put HO2 gain to 0.05
  • If put HO2 to 0.10 the would get stripes on the pyramid pupil image
  • Thought that maybe we were vignetting on the upper left part of the pupil (~10:00). Shifted X/Ry and Y/Rx but still not stable
  • Unstable Loop Pupil Image:
    unstable.jpg

-- %USERSIG{DougMiller - 2016-04-07}%
Topic revision: r3 - 08 Apr 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.