SX LUCI/AO Commissioning

02:30 Lost communication between the AOS and AO Arbitrator. Looks like specifically the wfsarb.
  • restarted wfsarb
  • restarted the AOS
  • sent presetAO and wfsarb died
  • restart wfsarb
  • next presetAO was successful

03:32 Bin 1, Gopt Test: Had some vibrations due to wind buffeting
  • Gopt OFF
    • 033317
    • 033401
    • 033431
  • Gopt ON, NCPA OFF
    • 033520
    • 033544
    • 033629
  • NCPA ON
    • 033721
    • 033747
    • 033811

03:38 Take Background

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20160322_033317 ??? 9.6 239688 10 0.91 0.51 184300 1 400 990 1.4 0.8 0.5 3 86 ON 37.2 FeII clear 172 50 ONSKY zero.fits - long stop of 58 frames at frame 1169
20160322_033401 ??? 9.7 239127 13 0.92 0.57 184300 1 400 990 1.4 0.8 0.5 3 81 ON 37.7 FeII clear 172 50 ONSKY zero.fits - long stop of 66 frames at frame 2347
20160322_033431 ??? 9.7 238749 12 1.03 0.62 184300 1 400 990 1.4 0.8 0.5 3 80 ON 38.7 FeII clear 172 50 ONSKY zero.fits  
20160322_033520 ??? 9.7 238146 8 1.06 0.70 184300 1 400 990 0.5 0.3 0.2 3 79 ON 34.7 FeII clear 172 50 ONSKY zero.fits - long stop of 129 frames at frame 687
20160322_033544 ??? 9.7 237835 12 0.95 0.69 184300 1 400 990 0.5 0.3 0.2 3 81 ON 36.7 FeII clear 172 50 ONSKY zero.fits - long stop of 63 frames at frame 3780
20160322_033629 ??? 9.5 237274 12 0.89 0.55 184300 1 400 990 0.5 0.3 0.2 3 93 ON 38.6 FeII clear 172 50 ONSKY zero.fits - long stop of 86 frames at frame 3195
20160322_033721 ??? 9.5 236611 13 0.91 0.58 184300 1 400 990 0.5 0.3 0.2 3 95 ON 41.3 FeII clear 172 50 ONSKY zero.fits - long stop of 67 frames at frame 54
20160322_033747 ??? 9.5 236284 11 0.92 0.56 184300 1 400 990 0.5 0.3 0.2 3 94 ON 40.4 FeII clear 172 50 ONSKY zero.fits - long stop of 92 frames at frame 1065
20160322_033811 ??? 9.5 235988 13 0.96 0.60 184300 1 400 990 0.5 0.3 0.2 3 93 ON 35.2 FeII clear 172 50 ONSKY zero.fits  
IDL string: ['20160322_033317','20160322_033401','20160322_033431','20160322_033520','20160322_033544','20160322_033629','20160322_033721','20160322_033747','20160322_033811']
SR 0 (NaN)
SEEING (WFS) 0.596983 (0.063472)
SEEING (DIMM) 0.94857 (0.0581957)

03:48 Bin2 Gopt Test, out of the wind
  • Changed to bin 1
  • will do bin 4

04:00 AcquireRefAO failed
  • A lot of Cirrus so there is a background gradient on CCD47.
  • finding centroid of background not of reference star.
  • moves ref out of the field of view
  • Can set by hand and then run acquirerefao

04:25 Bin 4 Gopt Test => Oops, Only 12 modes frown, sad smile
  • Gopt OFF
    • 042437
  • Gopt ON, No NCPA
    • 043016

04:34 Background

04:44 Data not good.