Title

Plan for today

  • Repeat strehl measure at 330, 300
  • Rotate 0-360 and check by eye that the PSF does not change much
  • Insert seeing and measure Strehl
  • Test tracking of amps -vs- rotator
  • Measure more angles

Details

01:45 ARGOS Source ready and we start

01:50 We see ARGOS source on CCD47

01:55 Closed loop

02:19 Rotator 330 strehl measurement
  • With NCPA (without -10 focus)
    • 142614
    • 142643
    • 142719
  • With NCPA (and focus) with bad pixel
    • 143122
    • 143204
    • 143226
  • With NCPA (with focus) without bad pixel
    • 143808 58%
    • 143843 59%
    • 143908 60%
  • Without NCPA
    • 144006 56%
    • 144033 56%
    • 144054 55%

02:45 Installed AGROS CalUnit Hexapod numbers in SXSMRETROREFFCollimation.dat
  • 4.8, 1.7, -0.63, 43, -108
  • Can now authorize as RETROREF to get ARGOS source aligned
  • Comment in or out values for Retro or ARGOS

02:57 Rotator at 270, no NCPA
  • 145627 51%
  • 145653
  • 145724

03:07 Rotator at 210, no NCPA
  • 150648 52%
  • 150704 52%
  • 150732 52%

03:17 Rotator at 150, no NCPA
  • 151631 49%
  • 151658 49%
  • 151727 49%

03:24 Rotator at 90, no NCPA
  • 152515 62%
  • 152542 63%
  • 152604 64%

03:32 Rotator at 30, no NCPA
  • 153105 49%
  • 153126 50%
  • 153151 50%

03:45 Rotator at 150 (worst Strehl with no NPCA)
  • Z4-Z11: 16, 23, -58, 0, 10, 15, 10, -12
  • 20160313_150_deg_2.fits
  • Done at 04:32

04:30 Create disturbance file with 0.8" seeing and
  • print, sinsusmode_generate(4, 10-9, 30, 990, "KL_v20", /even, add_file="/home/flao/TEST/calib/adsec/672b/CMD/dist_flao_KL_v20_atm_s0.8_L040_v15.0_ovfreq1000.00_sd3892.fits")
  • 20160313_162559
  • In RR mode and ARGOS the seeing was 0.8/2 because disturb file build for double pass (rr) but now single pass (CalUnit)

04:33 Rot 150, NCPA on, No Distrub
  • 163229
  • 163305
  • 163326

0434 Rot 150, NCPA off, No Disturb
  • 163405
  • 163419
  • 163439

06:21 Searching for problem with auto gain limits for 0.8 rather than 1.0 or higher (shift if needed)
  • Shifting was not working because it shifts if minimum is > 0.8 of max value (1.0 in this case). However, with python counting, we drop last point (1.0) and only go to 0.8. This is always less then 80% of max value.
  • Change config file ~/TEST/conf/wfs/672b/processConf/autogain.conf
  • Change bin1_step = 0.1 (form 0.2)

06:47 Rot 150, NCPA off, Distrub 1.5/2
  • 184720 44%
  • 184744
  • 184821

06:48 Rot 150, NCPA on, Disturb 1.5/2
  • 184859 55%
  • 184937
  • 184958

08:17 Start NCPA measurements at 120 degrees
  • Z4 10
  • Z5 -40
  • Z6 -15
  • Z7 -5
  • Z8 4
  • Z9 7
  • Z10 -10
  • Z11 -8

09:01 Done with 120 degrees
  • 20160313_120_deg.fits

09:03 120 degrees, NCPS
  • 210310
  • 210326
  • 210341

09:04 120 degrees, NP
  • 210412
  • 210427
  • 210442