SX NCPA Measurement

wfs machine

Generate sinusoidal disturb for Gopt

~/TEST/lib/python/AdOpt/WfsArbScripts/select_disturbance.py

Python search for needed file according to amplitude frequency of sinusoidal frequency of loop

if not available then call IDL part

~/TEST/idl/wfs_lib/sinusmode_generate.pro

aoidl IDL> print, sinusmode_generate(4, 10e-9, 30, 990, \x93KL_v20\x94, /EVEN) 20160312_153051

/towerdata/adscec_calib/M2C/KL_v20/disturb/20160312_153051

Load this via the AdSec Control GUI Disturbance

Focus Change

=> can make large movements in focus (2-3 mm) => then loop at peak on LUCI readout (1500 - 3000 counts)

Move PSF to area with no bad pixels

% AutoFocusLuci.py

range = 2 step = 0.2 image = 20 x, y 64, 64

original stage position = 53

When find best focus with ARGOS source, this should be the same focus at on-sky. Will check on-sky. ARGOS source is better to determine focus than on-sky because no turbulence.

frames saved in $ADOPT_MEAS/autoFocus47/

X Display error

To run the routine

aoidl

IDL> psf_focus, '21060312_160502', 10, peak, cx=64, cy=64, MASK=30

peak is output Mask is size of box

Best focus = 54.6

Start Measuring NCPA

Start GoptGUI

Load disturbance file Sync disturb Close loop, 1 kHz, bin 1, 3 lam/D

Automatic NCPA determination routine

~/TEST/bin/luci_ncpa.py

Edit file with favorite editor

uncomment mode you want to scan

mode[4] = [ -60, 80, 20 ] will do -60 to 60 (not 80 because python counting)

Can set non-scan modes to value

restart[9] = -10

  • Make sure LUCI display in not in Endless mode
  • Set save type to CUBE

% luci_ncpa.py

Need LUCI dark
  • WFS Control GUI - collect PICSES image.
  • collect the same number of darks as collection for NCPA measurements

NCPA at 330

z5-z11 -15, 0, 8, 10, -10, -10, -4

Optical Loop Data
  • 182952
  • 183916
  • 183943

$ADOPT_ROOT/calib/wfs/current/ncpa/20160312_330.fits

NCPA at 300

06:40 Rotation done, start setting up and collect data

07:40 About done, but communication problem that required the WFS Arbitrator to be restarted

08:05 Problem "fixed"

08:06 ncpa file 20160312_300.fits

This includes a focus scan. Found 12 nm

08:08 Optical Loop Data
  • 200851
  • 200941
  • 201005

Go back to 330 and do focus scan
  • Find same focus ~12 nm

Zabbix

http://wfssx/zabbix A*** z***

Board setups

~/TEST/calib/wfs/current/setups

08:10 Done. Hand over to ARGOS

Final hexapod position 4.8, 1.7, -0.63, 43, -108

On rm525-1
  • open_observer luci Observer
  • open_observer luci RTD
  • open_observer luci GEIRS

-- %USERSIG{DougMiller - 2016-03-12}%
Topic revision: r3 - 12 Mar 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.