DX Reconstrutor Measurements

04:40 RR mounted and ready to go

04:55 start hexa_spiral(1000e-6, 15, /app) Note, the SX version does not move focus by 4+ as the first step. Had to set hexapod z to 9.0 and then start spiral

06:50 Found source near yesterday's values
  • LUCI2 calibration unit was in and Argon light source on.

06:53 Closed loop

06:59 Rotate cube to 24.422
  • looks fine
  • no dust

07:08 Acquire
  • Disturb from yesterday
    • 223701
    • doug_400_2l_0.4
  • 48 iter
  • 191036

07:25 Analyze
  • 192532

07:34 Flat saved
  • 20160302_2.sav

07:36 Acquire
  • 12 iter
  • 193553

07:41 Analyze
  • 194022
  • break loop with 0.05 TT. no good
  • add big TT to adsec. Remove

08:10 Acquire
  • disturb 223701
  • iter 12
  • 201144

08:16 Analyze
  • 201626

08:18 Flat saved
  • 20160302_4.sav

08:24 Test of 201626
  • 1 kHz
  • dist_flao1_tx4_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd1983.fits
  • 202537
    • modal plot shows some oscilating
  • 202720

08:46 Acquire
  • disturb 223701
  • flat 20160302_4.sav
  • iter 12
  • 204345
  • analyze failed (maybe wrong camera speed)

08:49 Distrub
  • doug_400_2l_0.6.fits
  • 204859

08:50 Acquire
  • doug_400_2l_0.6.fits
  • 4 iter
  • 205045

08:52 Analyze
  • 205214
  • 20160302_5.sav flat

08:55 Acquire
  • 20160302_6.sav flat
  • disturb 204859
  • 205600

08:57 Analyze
  • 205729

09:02 Test 205729
  • 210223
  • Modalplot had less correction on high order modes at same gain

09:05 Disturb
  • doug_400_2l_0.3.fits
  • 210546

09:06 Acquire
  • Loop skips

09:09 Disturb
  • doug_400_2l_0.3.fits
  • 210912

09:10 Acquire
  • Loop skips with doug_400_2l_0.3.fits
  • tried with older recon 205729

09:14 Acquire
  • recon 205729
  • disturb 210912 with doug_400_2l_0.3.fits
  • 211304

09:17 Analyze
  • 211639

09:19 Test of 211639
  • Top edge rolls
  • loop opens with skip frame

09:27 Acquire
  • disturb 223701 with doug_400_2l_0.4.fits
  • recon 205214
  • flat 20160302_5.sav
  • 48 iter
  • 213327

09:51 Analyze * 215035

10:01 Test 215035
  • gain 0.5, 0.5, 0.5
    • 215952
  • gain 0.5, 0.45, 0.4
    • 220219
  • gain 0.4, 0.65, 0.55
    • 220441
  • autogain 0.5, 0.58, 0.39
    • 220819
  • gain 0.5, 0.4, 0.4
    • 220924

10:14 Analyze 213327
  • 221028
  • 350 modes

10:15 Test 221028
  • gain 0.5, 0.4 0.3
    • 221612
  • gain 0.5, 0.4, 0.4
    • 221642

Bin 2

10:23 Disturb
  • 10 modes
  • 45 cycle
  • 4 frames
  • doug_400_2l_0.4.fits
  • 222328

10:25 Acquire
  • open loop
  • 4 iter
  • 222427
  • analyze failed on SVD

10:27 Acquire
  • open loop
  • 4 iter
  • 222755

10:29 Analyze
  • 222926

10:30 Acquire
  • closed loop
  • recon 222926
  • 4 iter
  • 223036

10:32 Analyze
  • 223206

10:33 Disturb
  • doug_400_2l_0.4.fits
  • 4 frames
  • 7 cycles
  • 223338

10:33 Acquire
  • 4 iter
  • 223424

10:35 Analyze
  • 223603

10:37 Disturb
  • 153 modes
  • 3 cycles
  • doug_400_2l_0.4.fits
  • 223723

10:38 Acquire
  • 4 iter
  • checked cube rot. OK
  • 22392
  • Analyze failed

10:40 Acquire
  • 224211

10:43 Analyze
  • 224340

10:45 Test 224340
  • gain 0.5, 0.3, 0.3
    • 224647

10:47 Acquire
  • 12 iter
  • recon 224340
  • 224758 (oops, 990 Hz)

10:48 Hexapod
  • -0.86, -0.5, 3.96, -43.90, 12.1

10:51 Acquire
  • 12 iter
  • recon 224340
  • 225243

10:56 Analyze
  • 225637

10:57 Test of 225637
  • gain 0.3, 0.3, 0.35
    • 225844
  • gain 0.5, 0.2, 0.25
    • 225922
  • gain 0.5, 0.35, 0.35
    • 230018

-- %USERSIG{DougMiller - 2016-03-02}%
Topic revision: r4 - 03 Mar 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback