DX Reconstuctor Measurements

04:20 Telescope and RR ready

05:00 Found spot, moved to center, some coma

05:30 Closed loop with bin 4 from KL_v16. No problems
  • offload to hexapod
  • hex -1.33, -0.54 4.1 -47.93, 3.66
  • M3, -900, 100, 0, -25.72

05:47 Disturb
  • KL_v21
  • 10 modes
  • 4 frames
  • 45 cycles
  • optimized_amano_6ldiv2.fits
  • 174406

05:48 Acquire
  • 4 iter
  • open loop
  • 174549

05:50 Analyze
  • 174906
  • can close the loop, but not much change

05:54 Strange that when we try to load the new recon, with the correct pupil file loaded via change_binning.py 1, we always get a box that says the pupil is incorrect, should be 2015 pupil instead.

06:03 Disturb
  • optimize_2lambda.fits
  • KL_v21
  • 10 modes
  • 4 frames
  • 45 cycles
  • 180301
  • too small

06:06 Disturb
  • optimized_amano_6l.fits
  • 180548
  • too much, loop broke

06:08 Disturb
  • gain0.3.fits
  • 180811

06:09 Acquire
  • open loop
  • troubles closing the loop. Communicating to AdSec

06:21 adsc_stop/start

06:28 Can close loop now

06:28 Acquire
  • disturb is still small
  • 184307

06:44 Analyze
  • 184502

06:47 Distrub
  • gain0.7.fits
  • 184750 *184914 *185128

06:55 Disturb
  • optimized_2lambda.fits
  • 190719

06: 59 Acquire
  • 190915

07:05 Analyze
  • 191057

07:17 Acquire
  • 191530

07:19 Analyze
  • 191804

07:21 Disturb
  • 50 modes
  • 192110

07:23 Acquire
  • 192214

07:25 Analyze
  • 192358

07:40 Disturb
  • 153 modes
  • optimized_2lambda.fits
  • 194001

07:46 Acquire
  • 600 Hz
  • 3 lam/D
  • 194451

07:48 Analyze
  • 194658

07:56 Move cube stage in close loop to see if "spot" moves. Seems to.
  • orig -4.4
  • new -2.3

07:59 move cube stage and bayside stages
  • move cube stage to -2.3 (move ~8" on CCD47)
  • bayside stage original = -72.6, -49.9
  • move bayside to -74.7, -49.9
  • no more dust spot
  • cube rotation 203.809

08:10 Acquire
  • 153 modes
  • disturb 194001
  • 200647

08:15 Analyze
  • 201020

08:16 Disturb
  • 400 modes
  • 201612

08:19 Acquire
  • 201479

08:20 Analyze
  • 201940

08:51 Acquire
  • 48 iter
  • 202800

08:56 Analyze
  • failed, bad data

08:57 Acquire
  • iter 12
  • 205724

09:20 Analzye
  • 210123

09:10 Create new gain fiile
  • IDL> fits_read, '/home/aoacct/AO/current/calib/adsec/current/M2C/KL_v21/modesAmp/optimized_2lambda.fits' orig
  • restore, 'Intmat_20160301_210123.fits_data.sav', /v
  • new = orig
  • new[2:399] = (orig[2:399]/devs[2:399])*0.3

09:11 Disturb
  • doug_400_2l.fits
  • 211012

09:13 Acquire
  • 211207

09:16 Analyze
  • 211345

09:29 Test of 210123
  • gain optimized_2lambda.fits recon
  • 212843

09:30 Test of 211345
  • Doug_400_2l.fits
  • 213030

09:41 Acquire
  • doug_400_2l.fits
  • 12 iter
  • 213715

09:44 Analyze
  • 214146

09:48 est of 211345
  • Doug_400_2l.fits
  • 214748

09:54 Test of 211345
  • dist_flao1_tx4_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd1983.fits
  • 215337

10:00 Test of 210123
  • dist_flao1_tx4_atm_s0.8_L021474840.0_v15.0_ovfreq1000.00_sd1983.fits
  • 220023

10:09 Disturb
  • optimized_2lambda
  • 400
  • 220958

10:10 Acquire
  • Close loop with 153 mode recon = 201020
  • 221933

10:21 Analyze
  • 222121
  • Loop break immediately with 0.05 TT gain

10:32 Analyze
  • 223203

10:37 Disturb
  • doug_400_2l_0.4.fits
  • 223701

10:43 Acquire
  • 224159

10:44 Analyze
  • 224340

10:47 Test of 224340
  • dist_flao1_tx4_atm_s0.8_L040.0_v15.0_ovfreq1000.00_sd1983.fits
  • 224946

Cannot create a modal plot
IDL> ao_init
AO> a = getaoelab('20160301_214748')
AO> a->modalplot
% Compiled module: GETM2C.
% Compiled module: AOM2C__DEFINE.
% Compiled module: CHECKSUM32.
% Compiled module: N_BYTES.
% CHECKSUM32: ERROR - Number of bytes in supplied array must be a multiple of 4
% Execution halted at: CHECKSUM32         47 /usr/local/itt/idl71/lib/astrolib/checksum32.pro
%                      AOM2C::C2M         52 /home/aoacct/AO/current/idl/elab_lib/aom2c__define.pro
%                      AOCONTROL::C2M    135 /home/aoacct/AO/current/idl/elab_lib/aocontrol__define.pro
%                      AOMODALPOSITIONS::DATIPRODUCER   54 /home/aoacct/AO/current/idl/elab_lib/aomodalpositions__define.pro
%                      AOMODALPOSITIONS::GETDATI   71 /home/aoacct/AO/current/idl/elab_lib/aomodalpositions__define.pro
%                      AOTIME_SERIES::COMPUTE   35 /home/aoacct/AO/current/idl/elab_lib/aotime_series__define.pro
%                      AOTIME_SERIES::NSERIES  138 /home/aoacct/AO/current/idl/elab_lib/aotime_series__define.pro
%                      AOMODALPOSITIONS::NMODES   66 /home/aoacct/AO/current/idl/elab_lib/aomodalpositions__define.pro
%                      AOELAB::MODALPLOT  653 /home/aoacct/AO/current/idl/elab_lib/aoelab__define.pro
%                      $MAIN$          
AO> 

-- %USERSIG{DougMiller - 2016-03-01}%

Comments

 
Topic revision: r2 - 01 Mar 2016, DougMiller
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback