LUCI2 NCPA measurements

startProcessByName(): starting process /home/aoacct/AO/current/bin/gopt.py -i gopt
Traceback (most recent call last):
  File "/home/aoacct/AO/current/bin/w_start", line 175, in ?
    if __name__ == '__main__': main()
  File "/home/aoacct/AO/current/bin/w_start", line 143, in main
    processControl.waitProcessStart( app, process)
  File "/home/aoacct/AO/2015Atest/lib/python/AdOpt/processControl.py", line 241, in waitProcessStart
    raise AOExcept.AdOptError( AOConstants.AOErrCode['TIMEOUT_ERROR'], "Timeout error waiting for process %s start" % process)
AdOpt.AOExcept.AdOptError: Timeout error waiting for process gopt start - code: -5001 TIMEOUT_ERROR

[AOeng@wfsdx ~]$ w_check Configuration directory: /home/aoacct/AO/current/conf/wfs/current/processConf

msgdrtdb             running
mirrorctrl           running and connected to Msgd
pinger               running and connected to Msgd
masterdiagnostic     running and connected to Msgd
slopecompctrl        running and connected to Msgd
techviewctrl         running and connected to Msgd
powerboard           running and connected to Msgd
picctrl              running and connected to Msgd
ccd39                running and connected to Msgd
ccd47                running and connected to Msgd
ttctrl               running and connected to Msgd
adc1                 running and connected to Msgd
adc2                 running and connected to Msgd
filterwheel1         running and connected to Msgd
filterwheel2         running and connected to Msgd
rerotator            running and connected to Msgd
mercury              running and connected to Msgd
cubestage            running and connected to Msgd
baysidex             running and connected to Msgd
baysidey             running and connected to Msgd
baysidez             running and connected to Msgd
cameralensctrl       running and connected to Msgd
housekeeperWFS       running and connected to Msgd
optloopdiag          running and connected to Msgd
dbfiller             running and connected to Msgd
od_gopt              running and connected to Msgd
wfsarb               running and connected to Msgd
gopt                 running and connected to Msgd

[AOeng@adsecdx ~]$ adsc_check Configuration directory: /home/aoacct/AO/current/conf/adsec/current/processConf

msgdrtdb             NOT running
adamhousekeeper      running but NOT connected to Msgd
mirrorctrl           running but NOT connected to Msgd
pinger               running but NOT connected to Msgd
masterdiagnostic     running but NOT connected to Msgd
idlctrl              NOT running
housekeeper          running but NOT connected to Msgd
fastdiagn            running but NOT connected to Msgd
adsecarb             NOT running
AOARB                NOT running
varsmonitor          running but NOT connected to Msgd
anemometermon        NOT running
lnIFserver           running but NOT connected to Msgd
No AdOpt processes are running

03:03 adsc_stop, adsc_start ** AOSGUI says Retoreflector Installed
  • $ disable_rr_mode.sh turned off AOS light

03:07 DX AdSec is powered on (not by me) and last executed was Recover Fail

03:12 Power off, Power on, Set: OK

03:19 Power on WFS. Board Setup to calunitnight

03:25 Deploy ARGOS swing arm and turn on

03:40 Check PSF. tertiary and secondary in the correct place. Star is on N3.75. Also on N30

03:46 PresetAO from AOSGUI. Star is on acquisition camera. Change focus to 4.1
  • -1.1, -4.65, 4.1, -120, 270, 0

03:49 Tom put LUCI2 in to subwindow mode

03:56 AcquireRef failed because re-rotator was not getting updated instrument rotator information. This was because we restarted the AdSec processes. The msgd looses all registered variables so WFS arbitrator has to re-register the variables it needs.

04:11 AdSec Rip. Alfio says it was a fast diagnostic error. Maybe an actuator jumped. #259 had high force (0.7)

04:25 Started an NCPA loop but endless mode was on in LUCI2. Now the communication is stuck.

04:52 Alexander online. trying to fix

79.702 0.51, 0.22, 0.18

05:25 Set loop gain to 0.0, turn off lamp, and collect 20 dark LUCI2 frames

05:31 Turn on lamp, set gain to 0.1. Rip. Camera lens was not in proper position.
  • should have turned off camera lens when set loop gain to 0.
  • turn on lamp, turn on camera lens and let it recenter before ramping up gain.

05:33 Preset, Acquire and StartAO

05:38 Collect focus run for NCPA with values from yesterday at 210 degrees
  • oops, forgot to turn on Optical Gain

@ 210
restart[4]  =  -26 # 59.7
restart[5]  =  -59 #-35.0  # 0.9 # 3.5
restart[6]  =  -40 #30 # 30.0 # 16.0
restart[7]  =  12.3 # -30 # -12.0 # -17 ???
restart[8]  =  -3 #-30 # 2.0 # -11.0
restart[9]  =  0 #15 #  4.0
restart[10] =  -18 #0 # -7.5
restart[11] =  5 #-36 # -12

05:42 Turn on Optical Gain Collect 3 sets. Finally get focus at -27

06:03 Open loop and change rotator to 270 degrees

06:16 Could not find star. Moved back to 210, then steps of 10 and moved the stage to keep the star on the acquisition camera.
  • -43, -57
  • preset with -33, -5
  • OK, see star on
  • move star back to center of LUCI1 by moving stage to -65, -79

06:42 get SR = 11!! background trouble

06:55 Take new dark OK now

@ 270
restart[4]  =  0 # 59.7
restart[5]  =  38 #-35.0  # 0.9 # 3.5
restart[6]  =  75 #30 # 30.0 # 16.0
restart[7]  =  0 # -30 # -12.0 # -17 ???
restart[8]  =  0 #-30 # 2.0 # -11.0
restart[9]  =  0 #15 #  4.0
restart[10] =  0 #0 # -7.5
restart[11] =  0 #-36 # -12

07:25 Retract ARGOS swing arm, turn off lamp, disable_rr_mode.sh, rest shell, power off WFS