NCPA tests with LUCI2/AO

02:50 Power on DX WFS

03:02 change the default LUCIFER.sav from 20131021_600modes_4d.sav to 20150325_400modes.sav. The later was measured in March and has some coma to counteract the coma from using the ARGOS swing arm. Will remake the link back to the original at the end of the test.

03:10 Move ARGOS swing arm in and turn on.

03:20 Setup M2 Hexapod
  • -1., -3.6, 4.3, -530, 272, 0
  • -1.1, -3.6, 4.3, -300, 200

03:45 Set tertiary tip/tilt to 0, 20 (from -200, 250)
  • M2 Hexapod -1.1, -4.65, 4.3, -120, 270

04:09 Find start WUnit stage position
  • center -76.2 -51.2
  • need -65, -81
  • PresetAO need -10, -30 (sign flip in X offset, but not Y)
  • Outside limit error. Alfio set SW limit from -80 to -82

04:17 AcquireRef

04:20 BCU47 powered off. Camera lens moved to 0,0

04:24 BCU47 powered back on.

05:30

06:01 Pause Loop and collect LUCI (Pisces) dark: failed because loop is paused....feature that will be changed

06:04 Dark tracking number 20150420_180435

06:01 Start collecting data. Rotator at 210 degrees

Mode 5: -40
Saved tracknum:  20150420_181152
Mode 5: -20
Saved tracknum:  20150420_181214
Mode 5: 0
Saved tracknum:  20150420_181234
Mode 5: 20
Saved tracknum:  20150420_181256
Mode 5: 40
Saved tracknum:  20150420_181318

06:15 Do second set with -80, 0, 20

Step 0 - SR: 0.497
Step 1 - SR: 0.527
Step 2 - SR: 0.486
Step 3 - SR: 0.488
Maximum amp: -59.5
Best modal coefficients:
Mode  5  coefficient -59.5

Mode 6: -40
Saved tracknum:  20150420_182323
Mode 6: -20
Saved tracknum:  20150420_182343
Mode 6: 0
Saved tracknum:  20150420_182404
Mode 6: 20
Saved tracknum:  20150420_182424
Mode 6: 40
Saved tracknum:  20150420_182444

Step 0 - SR: 0.528
Step 1 - SR: 0.502
Step 2 - SR:   0.5
Step 3 - SR: 0.499
Step 4 - SR:  0.46
Maximum amp:   -40
Best modal coefficients:
Mode  6  coefficient   -40

06:28 Collect another set

Step 0 - SR: 0.452
Step 1 - SR: 0.477
Step 2 - SR: 0.489
Step 3 - SR: 0.478
Maximum amp:   -40
Best modal coefficients:
Mode  6  coefficient   -40

Step 0 - SR: 0.446
Step 1 - SR: 0.461
Step 2 - SR:  0.49
Step 3 - SR: 0.478
Step 4 - SR: 0.473
Maximum amp:  12.3
Best modal coefficients:
Mode  7  coefficient  12.3

Step 0 - SR: 0.459
Step 1 - SR: 0.493
Step 2 - SR: 0.519
Step 3 - SR: 0.475
Step 4 - SR: 0.445
Maximum amp: -3.29
Best modal coefficients:
Mode  8  coefficient -3.29

Step 0 - SR: 0.478
Step 1 - SR: 0.461
Step 2 - SR: 0.473
Step 3 - SR: 0.488
Step 4 - SR: 0.451
Maximum amp: -10.3
Best modal coefficients:
Mode  9  coefficient -10.3

06:45 Set Z9 to 0.0

Step 0 - SR: 0.488
Step 1 - SR:   0.5
Step 2 - SR: 0.481
Step 3 - SR: 0.481
Step 4 - SR: 0.458
Maximum amp: -22.1
Best modal coefficients:
Mode  10  coefficient -22.1

Step 0 - SR: 0.451
Step 1 - SR: 0.486
Step 2 - SR: 0.495
Step 3 - SR: 0.513
Step 4 - SR:  0.52
Step 5 - SR: 0.487
Maximum amp:   -18
Best modal coefficients:
Mode  10  coefficient   -18

06:58 In March they measured at every 50 degrees. Barely enough points for trefoil. We should do 30 degree step, but start with 60 and then fill in.

Step 0 - SR: 0.408
Step 1 - SR: 0.439
Step 2 - SR: 0.476
Step 3 - SR: 0.488
Step 4 - SR: 0.469
Step 5 - SR:  0.51
Step 6 - SR:  0.49
Step 7 - SR: 0.477
Step 8 - SR: 0.414
Step 9 - SR: 0.431
Maximum amp:  5.61
Best modal coefficients:
Mode  11  coefficient  5.61

Step 0 - SR: 0.505
Step 1 - SR: 0.529
Step 2 - SR: 0.496
Step 3 - SR: 0.451
Step 4 - SR: 0.411
Maximum amp: -26.2
Best modal coefficients:
Mode  4  coefficient -26.2

restart[4]  =  -26 # 59.7
restart[5]  =  -59 #-35.0  # 0.9 # 3.5
restart[6]  =  -40 #30 # 30.0 # 16.0
restart[7]  =  12.3 # -30 # -12.0 # -17 ???
restart[8]  =  -3 #-30 # 2.0 # -11.0
restart[9]  =  0 #15 #  4.0
restart[10] =  -18 #0 # -7.5
restart[11] =  5 #-36 # -12




-- %USERSIG{DougMiller - 2015-04-20}%