UT 20130915 AO#2 DX

Observer:JCGuerra(LBTO),SEspostio,LBuzoni,RBruglio,APuglisi (Arcetri Observatory)
Telescope Operator:
SW Support:
AO Support:
Telescope Support:
Instrument Support: (LBTO)

Summary

  • Py-WFS set up an operations without any problem.
  • Check of the performances of the AO system.
  • Performances of the AO system of yesterday configuration applying a disturbance of 0.8".
  • Optimized the focus to work with the IRTC with the disturbance.
  • Improve the IntMat to avoid the outer rings to oscillate.
  • Load a KL (KL_v16) modal bases with the inner ring "slave" (force zero) and to built new INTMAT.
  • Performances of new reconstructors at 400 and 500 modes .
  • Comparison of KL modal bases.
  • Improve the Autogain procedure.
  • Acquisition of IRTC psf.
  • Requested about 1 hour to work in some technical issue in MODS during the team was in lunch break.
  • Test on sky of reconstructor 400 and 500 modes of the new KL .
  • Acquisition of PSF close loop on sky.
  • Very promising results of bin 1 with 400 modes on sky.
  • Dome close due humidity and clouds at 3:42
  • Hand-over 5pm
  • More details in the Arcetri report. Attached to this page

Detail

The FLAO system is power on and set up without any problem.

The mask has been checked at the time that RR was installed.

Adjustment of the rotator angle between the WFS and the telescope rotator. Change parameter in the configuration files.

Check of the reconstructor 20130914_232352 from yesterday to check stability without disturbance. Acquisition of IRTC PSF.

Disturbace of 0.8" seeing is built to check the performances of the reconstructor with an injected atmosphere. The close loop shows some diverging edge in the upper left of the pupils and some instability in the center ring. The forces applied in the center ring were close to -0.7N.

The data collected from the WFS and ASM were analysed to define the next steps to follow. In the analysis of the data it has been seen that some specifics modes apply to much force in the center ring. The work with this KL modal base stop and it is loaded a new KL modal base with the inner rings slaves (null force).

With this new KL (KL_v16) we started to build the INTMAT and the reconstructor to test.

Reconstructor for 10, 200 400 and 500 modes were built and tested. With the 400 modes and with a better flat of the ASM we can identify a few suapertures in the edge that they can be inserted in the pupil.

The test of the reconstructor for 400 modes with disturbance showed an improvement in the center showing a stable loop but the edge of the mirror was still diverging.

Looking the signal in the pupils it has been identifies a few subapertures (5 subap) which they were inserted in the pupil. The new pupil required to acquire and to build new INTMAT and reconstructor.

The reconstructor built at 10, 200, 400 and 500 modes were tested without and with disturbance. The 400 modes shows to be really robust during all the test at close loop and even when a disturbance of 1.6 " seeing was applied.

The telescope is open at twilight and the first 2 hours of the telescope were dedicated to trest the bin on sky. Seeing variable about 1.8" to 1.0", with this variables conditions the system has showed to be robust with 400 modes and even during the autogain process. We observed that the PSF was bouncing around too much and it a test with the tree house off was done.

It has been observe on sky with the tree house off for the last three measurements. Looking the seeing changes it is more possible that the loose of performances is due to rapid changes of the seeing. The telescope was pointing back to teh wind, elevation 65 and the side vent door close.

@ 3:42 The telescope close due to high humidity and clouds.

Results.

Close dome.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20130915_220435 ??? 6.6 90 4 NaN -1.00 214816 1 500 990 0.5 0.5 0.4 3 1391 ON 62.4 H 20 500 ON zero1600.fits  
20130915_220518 ??? 6.6 90 3 NaN -1.00 214816 1 500 990 0.5 0.5 0.4 3 1405 ON 63.2 H 20 500 ON zero1600.fits  
20130915_220600 ??? 6.6 90 3 NaN -1.00 214816 1 500 990 0.5 0.5 0.4 3 1404 ON 75.7 H 20 500 ON zero1600.fits  
20130915_220735 ??? 6.4 90 5 NaN -1.00 214816 1 500 990 0.5 0.5 0.4 3 1621 ON 75.5 H 20 500 ON zero1600.fits  
20130915_220818 ??? 6.5 90 5 NaN -1.00 214816 1 500 990 0.5 0.5 0.4 3 1575 ON 76.1 H 20 500 ON zero1600.fits  
20130915_220900 ??? 6.5 90 4 NaN -1.00 214816 1 500 990 0.5 0.5 0.4 3 1550 ON 76.9 H 20 500 ON zero1600.fits  
20130915_221258 ??? 6.5 90 4 NaN -1.00 191023 1 400 990 0.6 0.6 0.5 3 1461 ON 73.6 H 20 500 ON zero1600.fits  
20130915_221340 ??? 6.5 90 4 NaN -1.00 191023 1 400 990 0.6 0.6 0.5 3 1480 ON 74.3 H 20 500 ON zero1600.fits  
20130915_221422 ??? 6.5 90 4 NaN -1.00 191023 1 400 990 0.6 0.6 0.5 3 1516 ON 74.9 H 20 500 ON zero1600.fits  
20130915_221557 ??? 6.4 90 6 NaN -1.00 191023 1 400 990 0.6 0.6 0.5 3 1664 ON 73.1 H 20 500 ON zero1600.fits  
20130915_221639 ??? 6.4 90 5 NaN -1.00 191023 1 400 990 0.6 0.6 0.5 3 1628 ON 73.5 H 20 500 ON zero1600.fits  
20130915_221721 ??? 6.5 90 6 NaN -1.00 191023 1 400 990 0.6 0.6 0.5 3 1594 ON 74.5 H 20 500 ON zero1600.fits  

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20130915_234214 ??? 6.7 90 3 NaN -1.00 224932 1 400 990 0.8 0.7 0.5 3 1293 ON 56.3 H 20 500 ON zero1600.fits  
20130915_234257 ??? 6.7 90 4 NaN -1.00 224932 1 400 990 0.8 0.7 0.5 3 1295 ON 56.2 H 20 500 ON zero1600.fits  
20130915_234339 ??? 6.7 90 4 NaN -1.00 224932 1 400 990 0.8 0.7 0.5 3 1297 ON 39.6 H 20 500 ON zero1600.fits  
20130915_234514 ??? 6.7 90 4 NaN -1.00 224932 1 400 990 0.8 0.7 0.5 3 1298 ON 40.7 H 20 500 ON zero1600.fits  
20130915_234557 ??? 6.5 90 5 NaN -1.00 224932 1 400 990 0.8 0.7 0.5 3 1562 ON 41.1 H 20 500 ON zero1600.fits  
20130915_234639 ??? 6.5 90 4 NaN -1.00 224932 1 400 990 0.8 0.7 0.5 3 1589 ON 39.0 H 20 500 ON zero1600.fits  
20130915_234942 ??? 6.5 90 4 NaN -1.00 224932 1 400 990 0.5 0.6 0.5 3 1492 ON 48.4 H 20 500 ON zero1600.fits  

On Sky

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20130916_021711 ??? 7.8 78 7 1.17 0.77 224932 1 400 990 1.4 1.0 0.6 3 469 ON 79.1 H 5 1000 ONSKY zero.fits  
20130916_021826 ??? 7.8 78 6 1.04 0.75 224932 1 400 990 1.4 1.0 0.6 3 472 ON 87.6 H 5 1000 ONSKY zero.fits  
20130916_021942 ??? 7.8 77 6 1.11 0.97 224932 1 400 990 1.4 1.0 0.6 3 455 ON 55.9 H 5 1000 ONSKY zero.fits  
20130916_022720 ??? 7.8 76 7 1.04 0.75 224932 1 400 990 1.4 0.6 0.6 3 466 ON 57.1 H 5 1000 ONSKY zero.fits - Pupils not on target
20130916_022836 ??? 7.8 76 8 1.07 0.71 224932 1 400 990 1.4 0.6 0.6 3 466 ON 69.2 H 5 1000 ONSKY zero.fits - long stop of 51 frames at frame 1393
20130916_022951 ??? 7.8 76 6 1.03 0.91 224932 1 400 990 1.4 0.6 0.6 3 453 ON 56.7 H 5 1000 ONSKY zero.fits  
20130916_024144 ??? 8.0 74 8 1.33 1.28 223848 1 500 990 1.9 0.8 0.5 3 382 ON -1.0 ? -1 -1 ONSKY zero.fits - long stop of 55 frames at frame 8454
20130916_024452 ??? 7.9 73 7 1.13 1.07 224932 1 400 990 1.5 0.8 0.6 3 438 ON 48.4 H 5 1000 ONSKY zero.fits  
20130916_024609 ??? 7.8 73 8 1.17 0.77 224932 1 400 990 1.5 0.8 0.6 3 460 ON 70.5 H 5 1000 ONSKY zero.fits  
20130916_024725 ??? 7.8 73 8 0.94 0.79 224932 1 400 990 1.5 0.8 0.6 3 462 ON 68.9 H 5 1000 ONSKY zero.fits  

--++Tree house off.

TrackNo RefStar Mag El Wind DIMM/OL Rec bin #mod freq gain mod nph AntiDrift SR filter exp #frames disturb SN notes
20130916_032250 ??? 7.9 66 7 1.25 1.31 224932 1 400 990 1.4 1.0 0.6 3 416 ON 33.2 H 5 1000 ONSKY zero.fits  
20130916_032406 ??? 7.9 66 8 1.37 1.45 224932 1 400 990 1.4 1.0 0.6 3 403 ON 37.2 H 5 1000 ONSKY zero.fits  
20130916_032521 ??? 7.9 66 8 1.23 1.20 224932 1 400 990 1.4 1.0 0.6 3 419 ON 61.1 H 5 1000 ONSKY zero.fits  

-- JuanGuerra - 15 Sep 2013
  • on sky PSD with good psf and good strehl:
    plotjitter_onsky_goodpsf_1.png

  • on sky PSF with good strehl 400 modes:
    onsky_highstrehl_1.png

  • on sky PSF with poor strehl and tree house off:
    onsky_treehouseoff_oscillation_1.png

  • on sky PSD with poor strehl and tree house off:
    plotjitter_onsky1_0.png

  • on sky PSD with poor strehl and tree house on:
    onskypsdpoorseeingtreehouseon_0.png

  • on sky PSF with poor strehl and tree house on:
    onskypsfpoorseeingtreehouseon_0.png

I Attachment Action Size Date Who Comment
FLAO1reportV1.pdfpdf FLAO1reportV1.pdf manage 1 MB 16 Sep 2013 - 06:27 UnknownUser FLAO report,13,14 and 15
onsky_highstrehl_1.pngpng onsky_highstrehl_1.png manage 58 K 16 Sep 2013 - 06:06 UnknownUser on sky PSF with good strehl 400 modes
onsky_treehouseoff_oscillation_1.pngpng onsky_treehouseoff_oscillation_1.png manage 50 K 16 Sep 2013 - 06:08 UnknownUser on sky PSF with poor strehl and tree house off
onskypsdpoorseeingtreehouseon_0.pngpng onskypsdpoorseeingtreehouseon_0.png manage 7 K 16 Sep 2013 - 06:13 UnknownUser on sky PSD with poor strehl and tree house on
onskypsfpoorseeingtreehouseon_0.pngpng onskypsfpoorseeingtreehouseon_0.png manage 58 K 16 Sep 2013 - 06:14 UnknownUser on sky PSF with poor strehl and tree house on
plotjitter_onsky1_0.pngpng plotjitter_onsky1_0.png manage 7 K 16 Sep 2013 - 06:08 UnknownUser on sky PSD with poor strehl and tree house off
plotjitter_onsky_goodpsf_1.pngpng plotjitter_onsky_goodpsf_1.png manage 8 K 16 Sep 2013 - 06:06 UnknownUser on sky PSD with good psf and good strehl
Topic revision: r3 - 21 Sep 2013, JohnHill