Staff

Telescope Operator: David gonzalez.

Observers: Doug Miller (LBTO),Juan Carlos Guerra(LBTO)

Astronomer Support: Olga Kuhn(LBTO)

Summary

WFS_SX

01:15:00. w_stop/start

Software up and running.

Power on from the AOS. OK

Start

Temperature -3.5C.

Wind speed:~3m/s from and back

1:35. Seeing >1.3".

Troubles to collimate the right side guider.

Start-up Luci1 and to prepare it to get exposures.

1:50 DIMM not acquiring star. Problem to find a star in the current observing field.

CCD47 images

Images are been taken for the CCD47 using the Optical Loop data GUI. The images saved ok.

Track Number:#20141117_015505. Test 10 images.

TN:#_020758

The cubes are saved.

PRESET

ACE LEFT AND ACTIVE RIGHT

Target: NGC7686

iif_preset,oc_ngc7686, mode=ace,gs=31,rs=0,,/left

iif_preset,oc_ngc7686, mode=active,gs=31,rs=0,,/right

iif_binoc_preset

Mon Nov 17 02:14:42.328 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[286] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0645129[-0.0645129],roy:-0.0923766,mag:7.67,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

>Preset OKMon Nov 17 02:16:37.556 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[286] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Star magnitude 7.6.

NOTE: The filter 2 goes to empty, this can be setup to go to a different filter, just for the acquiring and centering the star in the pyramid

iif_runao,/left

RIP due to lost of elevation.

adsec.L |INF| 2883|2014-11-17 02:20:55.489229| MAIN > FSM Rip done.
adsecarb.L |INF| 368|2014-11-17 02:20:57.201053| COMMANDHANDLER > Command Rest (code 2010) successfully completed
20141711 02:20:58.8846 Alert: Error: COILS DISABLED

The AOS left is restarted.

AdsecRX rest from the SH images we can observe that the edges of the mirror is not flat, effect of missing subapertures.

The SET wasn't successful there is an actuator that is putting too much force; #367 0.55N. Power on and flaot, the actuator #367 showed the same problem in current too high.

The actuator #367 is disabled in current.

2:36 Power off the AdsecDX.

Run AO on the left side. The right side is in recover

Mon Nov 17 02:40:36.605 2014 aos.AcquireRef{FLAO}.failed - AcquireRef {FLAO}[4] - Camera lens centering did not converge after 180 seconds.

Mon Nov 17 02:43:40.728 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[6] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0279504[-0.0279504],roy:-0.0956795,mag:7.67,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 02:44:20.164 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[6] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

CCD39 freeze.

slopecompctrl.L |INF| 542|2014-11-17 02:47:43.713247| MAIN > Masterdiagnostic decimation set to 0
slopecompctrl.L |INF| 543|2014-11-17 02:47:45.004434| MAIN > Setting dark to /home/aoacct/AO/current//calib//wfs/current/ccd39/backgrounds/bin1/20141117_024745_antidrift.fits
slopecompctrl.L |INF| 544|2014-11-17 02:47:45.216218| MAIN > Dark set to /home/aoacct/AO/current//calib//wfs/current/ccd39/backgrounds/bin1/20141117_024745_antidrift.fits
slopecompctrl.L |INF| 545|2014-11-17 02:47:46.272748| MAIN > Enabling fastlink

Close loop manually and the the CCD39 freeze and the loop is close, but is not sending WFSframes to the SwitchBCU.

2:56 Power OFF WFSSX

AdsecDX back and load new flat: pennina_2.sav

Mon Nov 17 02:58:02.797 2014 aos.WfsOn.started - WfsOn [8] (wfs:FLAOWFS)

WfsArbitrator_13205|ERR| 108|2014-11-17 03:01:28.211919| MAIN > Errors for these devices: ['setupXYZstages']
WfsArbitrator_13205|ERR| 109|2014-11-17 03:01:28.211951| MAIN >
WfsArbitrator_13205|ERR| 110|2014-11-17 03:01:28.211971| MAIN > setupXYZstages: setup did not complete within 120 seconds
WfsArbitrator_13205|INF| 111|2014-11-17 03:01:28.212008| MAIN > Elapsed time: 205.40 seconds
Good WfsArbitrator _13205|DEB| 112|2014-11-17 03:01:28.212142| MAIN > arbFunc TurnSystemOn done.

NOTE:Changing the focal station from the Adsec Control GUI seems to resolve the problem of not receiving frames in the AdsecSX.

Mon Nov 17 03:07:10.985 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[10] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.00144332[0.00144332],roy:-0.096672,mag:7.67,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 03:09:21.087 2014 aos.PresetAO{FLAO}.failed - PresetAO {FLAO}[10] - Command timeout - -13107: Arbitrator interface generic error

WfsArbitrator _13205|INF| 227|2014-11-17 03:08:35.632388| MAIN > selectTVDark(): selected dark file 20141117_030835.fits
WfsArbitrator_13205|INF| 228|2014-11-17 03:08:35.632424| MAIN > calibTVDarkInternal(): done
WfsArbitrator_13205|ERR| 229|2014-11-17 03:10:05.731387| MAIN > Timeout error on baysidex (-5001) TIMEOUT_ERROR
WfsArbitrator_13205|ERR| 230|2014-11-17 03:10:05.731421| MAIN > Traceback (most recent call last):
WfsArbitrator_13205|ERR| 231|2014-11-17 03:10:05.731442| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 2508, in arbFunc
WfsArbitrator_13205|ERR| 232|2014-11-17 03:10:05.731461| MAIN > errstr = func(*args)
WfsArbitrator_13205|ERR| 233|2014-11-17 03:10:05.731480| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/WfsArbScripts.py", line 919, in doPrepareAcquireRef
WfsArbitrator_13205|ERR| 234|2014-11-17 03:10:05.731499| MAIN > app.stagex.waitTargetReached()
WfsArbitrator_13205|ERR| 235|2014-11-17 03:10:05.731517| MAIN > File "/home/aoacct/AO/current/lib/python/AdOpt/hwctrl/simplemotor.py", line 300, in waitTargetReached
WfsArbitrator_13205|ERR| 236|2014-11-17 03:10:05.731537| MAIN > raise AdOptError ( AOErrCode ['TIMEOUT_ERROR'], "Timeout error on " Kelf.name)
WfsArbitrator_13205|ERR| 237|2014-11-17 03:10:05.731571| MAIN > AdOptError: Timeout error on baysidex - code: -5001 TIMEOUT_ERROR

BaysideStageX stack.

Move manually..OK.

Mon Nov 17 03:15:30.389 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[12] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0118551[0.0118551],roy:-0.0964576,mag:7.67,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 03:16:09.599 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[12] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

03:17 Star out of the guider. Sent an Acquire preset.

Mon Nov 17 03:21:46.807 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[15] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0196861[0.0196861],roy:-0.0960902,mag:7.67,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 03:22:26.476 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[15] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Mon Nov 17 03:28:18.522 2014 aos.info - WFS: star found, estimated magnitude: 6.26

Mon Nov 17 03:28:23.039 2014 aos.info - Variable iif.DIMM.seeing is valid

Mon Nov 17 03:28:45.119 2014 aos.info - Adsec 672b-left loading reconstructor.

Mon Nov 17 03:28:46.802 2014 aos.info - Stages offset applied - dx: 0; dy: 0

Mon Nov 17 03:28:46.815 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[16] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.256 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Mon Nov 17 03:28:46.841 2014 aos.StartAO{FLAO}.started - StartAO {FLAO}[17]

Skip frame and the loop was open.

Mon Nov 17 03:30:22.365 2014 aos.info - TTF Offload request Z: -0.00244907 -0.240669 0.000326473

Mon Nov 17 03:30:25.180 2014 aos.info - HO offload command end

Mon Nov 17 03:30:25.882 2014 aos.info - HO offload: previous 8 requests ignored

Mon Nov 17 03:30:25.895 2014 aos.info - HO Offload request. Z: 0 0 0 0 17.6331 -7.40765 -4.504 3.57383 -13.1632 -0.613894 -5.33483 -0 0 0 0 0 0 0 -0 0 -0 0

Mon Nov 17 03:30:27.188 2014 aos.info - TTF offload command end

Mon Nov 17 03:30:28.382 2014 aos.info - Maximum skip reached

Mon Nov 17 03:30:28.414 2014 aos.error - Stopping WFS...

Mon Nov 17 03:30:28.682 2014 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: AOSet

Mon Nov 17 03:30:28.786 2014 aos.error - Stopping AdSec

Mon Nov 17 03:33:00.706 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[19] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0337203[0.0337203],roy:-0.0952383,mag:7.67,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 03:33:40.341 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[19] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:990 mag:0 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

MAIN > Loading: /home/aoacct/AO/current//calib//adsec/current/M2C/KL_v10/RECs/Rec_20120602_233509.fits

Mon Nov 17 03:38:16.493 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[20] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #1 freq:990 mag:6.187 nBins:1 nModes:400 r0:0 snMode:0 strehl:0 ttMod:3

Mon Nov 17 03:38:16.522 2014 aos.StartAO{FLAO}.started - StartAO {FLAO}[21]

The mirror is skipping frames.....

adsecarb.L |WAR| 714|2014-11-17 03:40:08.106607| MAIN > Skip frame detected!
adsecarb.L |WAR| 715|2014-11-17 03:40:10.155186| MAIN > Skip frame detected!

Track Number: 20141117_034121,
_034215,_034534,_034616

Star bright in the centre of Luci. 0007.fits.

Mon Nov 17 03:49:59.241 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[23] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.0549286[0.0549286],roy:-0.0928505,mag:12.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 03:51:20.151 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[23] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:0 nBins:4 nModes:5 r0:0 snMode:0 strehl:0 ttMod:6

3:53 dimm:1.52"

3:58 DIMM:1.9"-2"

Luci:0009.fits

TN:#_035925,_040013,_040050

4:07 DIMM:1.23"
Luci set: Luci.20141117.0010-0015

TN:#_040941,_041236,_041320,_041618

Mon Nov 17 04:19:01.642 2014 aos.Stop{FLAO}.complete - Stop{FLAO}[62]

Mon Nov 17 04:19:01.662 2014 aos.info - Updated variable AOARB.L.LOOPON: 0

Active optics preset

4:20 Collect Active optics data. Open loop
Luci set: Luci.20141117.0016-0020

Test Reconstructor with 10 modes:_044401

Optimize gain:_044851,_044905

Luci_0023.fits

Change link table TTM to 10 modes Reconstructor. Table_ESM-AO.txt to table_LUCIFER_TTM-AO.txt

Mon Nov 17 05:02:48.850 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[67] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.150153[0.150153],roy:-0.0737058,mag:12.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 05:03:21.419 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[67] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 05:04:32.055 2014 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[68] Mode: Move stages, Automatic acquire

Mon Nov 17 05:05:49.039 2014 aos.info - Updated variable adsecarb.L.FSM_STATE: AOSet

Mon Nov 17 05:05:54.093 2014 aos.info - WFS: star found, estimated magnitude: 12.81

Mon Nov 17 05:05:59.801 2014 aos.warning - Variable iif.DIMM.seeing expired

Mon Nov 17 05:06:19.495 2014 aos.info - Adsec 672b-left loading reconstructor.

Mon Nov 17 05:06:21.219 2014 aos.info - Stages offset applied - dx: 0; dy: 0

Mon Nov 17 05:06:21.247 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[68] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:12.811 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 05:06:21.273 2014 aos.StartAO{FLAO}.started - StartAO {FLAO}[69]

TN:#_050824
Luci Set: Luci.20141117.0024-0029

TN:#20141117_051152

5:15 DIMM: 0.98

5:25 DIMM:1.1"

Stop AO from AOS and the iif can not send offsets.

A new preset has to be sent to do the Active Optics. ACTIVE mode
Active Optics Preset

5:27 sending an active preset to collect open loop data
Luci Set: Luci.20141117_0030-0035

Mon Nov 17 05:41:11.653 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[110] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:0.204619[0.204619],roy:-0.0550458,mag:12.7,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 05:41:44.163 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[110] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 05:41:59.452 2014 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[111] Mode: Move stages, Automatic acquire

5:43 DIMM:1.1"

Mon Nov 17 05:43:21.384 2014 aos.info - WFS: star found, estimated magnitude: 12.81

Mon Nov 17 05:43:47.221 2014 aos.info - Adsec 672b-left loading reconstructor.

Mon Nov 17 05:43:48.922 2014 aos.info - Stages offset applied - dx: 0; dy: 0

Mon Nov 17 05:43:48.935 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[111] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:400 mag:12.807 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 05:43:48.951 2014 aos.StartAO{FLAO}.started - StartAO {FLAO}[112]

TN:#_054507
Luci Set: Luci.20141117_0036-0041

5:50.DIMM:1.32"

TN:#_055049,_055226,_055610

5:57 DIMM:1.1"
Stop Observation. LBTI take over: 06:00
Restart Observation: 9:40

10:04 DIMM:1.1"

Mon Nov 17 10:06:23.316 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[430] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-0.0605082[-0.0605082],roy:0.210122,mag:11.63,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 10:08:43.448 2014 aos.info - WFS: star found, estimated magnitude: 11.87

Mon Nov 17 10:09:10.815 2014 aos.info - Adsec 672b-left loading reconstructor.

Mon Nov 17 10:09:12.626 2014 aos.info - Stages offset applied - dx: 0; dy: 0

Mon Nov 17 10:09:12.638 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[431] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:625 mag:11.865 nBins:2 nModes:153 r0:0 snMode:0 strehl:0 ttMod:3

TN#:_101059,_101117,_101151,_101329
Luci Set: Luci.20141117_0042

10:13. DIMM:0.89"
Luci Set: Luci.20141117_0044-0048

TN:#_102229,_102252

Mon Nov 17 10:31:22.194 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[470] (aomode:ACE-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-22.0428[-22.0428],roy:-8.28952,mag:15.43,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

change preset to TTM

Mon Nov 17 10:32:48.697 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[472] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-22.0408[-22.0408],roy:-8.28962,mag:15.43,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 10:33:51.904 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[472] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

10:34 DIMM:0.92"

Mon Nov 17 10:33:51.904 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[472] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 10:36:56.742 2014 aos.info - WFS: star found, estimated magnitude: 16.34

Mon Nov 17 10:37:32.552 2014 aos.info - Adsec 672b-left loading reconstructor.

Mon Nov 17 10:37:34.315 2014 aos.info - Stages offset applied - dx: 0; dy: 0

Mon Nov 17 10:37:34.345 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[473] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:100 mag:16.339 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 10:37:34.370 2014 aos.StartAO{FLAO}.started - StartAO {FLAO}[474]

Note Optimize gain time: 14-11-17 10:37:41.618941| MAIN > Starting gain optimization procedure

-17 10:40:40.555694| MAIN > arbFunc optimizeGainInternal done.

10:40 DIMM:1.05"

TN:#_104217,_104445

Skip Frame. Loop Open
Luci Set: Luci.20141117_0049-

Mon Nov 17 10:45:27.087 2014 aos.info - TTF Offload request Z: 2.30991 -4.19891 0.014183

Mon Nov 17 10:45:28.659 2014 aos.Pause{FLAO}.started - Pause{FLAO}[426]

Mon Nov 17 10:45:28.766 2014 aos.info - Maximum skip reached

Mon Nov 17 10:45:28.807 2014 aos.error - Stopping WFS...

Mon Nov 17 10:45:29.037 2014 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: LoopPaused

Mon Nov 17 10:45:29.046 2014 aos.Pause{FLAO}.complete - Pause{FLAO}[426]

Mon Nov 17 10:45:29.051 2014 aos.info - Updated variable adsecarb.L.FSM_STATE: AOPause

Mon Nov 17 10:46:57.738 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[484] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-22.0207[-22.0207],roy:-8.29062,mag:15.43,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 10:47:53.558 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[484] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

10:51 DIMM:0.92"

Loop Open during the optimize gain

Mon Nov 17 10:56:21.834 2014 aos.info - TTF Offload request Z: 0.300683 -1.61173 -0.00104159

Mon Nov 17 10:56:25.999 2014 aos.info - Maximum skip reached

Mon Nov 17 10:56:26.013 2014 aos.error - Stopping WFS...

Mon Nov 17 10:58:34.577 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[488] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-22.0042[-22.0042],roy:-8.29048,mag:15.43,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 10:59:30.773 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[488] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

TN:#_110630,_110650,_110718,_111503
Luci Set: Luci.20141117_0050-0055

Mon Nov 17 11:23:27.481 2014 aos.info - Updated variable AOARB.L.LOOPON: 0

Active optics preset

Luci Set: Luci.20141117_0056-0061

11:41. DIMM:0.73"

Mon Nov 17 11:43:55.276 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[529] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-21.9382[-21.9382],roy:-8.28349,mag:15.43,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 11:44:50.703 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[529] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 11:45:08.773 2014 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[530] Mode: Move stages, Automatic acquire

Shell RIP

Mon Nov 17 11:46:15.278 2014 aos.AcquireRef{FLAO}.failed - AcquireRef {FLAO}[530] - Generic communication error (nobody replying or timeout)

Mon Nov 17 11:46:17.977 2014 aos.info - COILS DISABLED

Mon Nov 17 11:46:17.990 2014 aos.error - Recovering AdSec failure

IDLCTRL.L.log:

idlctrl.L |INF| 45011|2014-11-17 11:46:15.217751| MAIN > -1009
idlctrl.L |INF| 45012|2014-11-17 11:46:15.217779| MAIN > % READ_SEQ: READING ERROR BCU
idlctrl.L |INF| 45012|2014-11-17 11:46:15.217779| MAIN > .
idlctrl.L |INF| 45013|2014-11-17 11:46:15.217801| MAIN > EndCmd


Mon Nov 17 11:51:32.013 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[533] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:-21.9266[-21.9266],roy:-8.28148,mag:15.43,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 11:52:28.108 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[533] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

TN:#120040,_120056,_120259,_121515
Luci Set: Luci.20141117_0062-0067

Active optics preset

Luci Set: Luci.20141117_0068,_0073

Mon Nov 17 12:39:35.539 2014 aos.PresetAO{FLAO}.started - PresetAO {FLAO}[576] (aomode:TTM-AO,focst:bentGregorianFront,instr:LUCIFER,wfs:FLAOWFS,sox:0[0],soy:0,rox:12.0743[12.0743],roy:30.49,mag:14.4,cindex:0,,elev:nan,rotang:nan,grvang:nan,r0:0,skybr:nan,windsp:nan,winddir:nan)

Mon Nov 17 12:40:17.986 2014 aos.PresetAO{FLAO}.complete - PresetAO {FLAO}[576] - dx:nan dy:nan slNull: f1:Filter #0 f2:Filter #0 freq:312 mag:0 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 12:40:50.649 2014 aos.AcquireRef{FLAO}.started - AcquireRef {FLAO}[577] Mode: Move stages, Automatic acquire

Mon Nov 17 12:42:00.667 2014 aos.info - WFS: star found, estimated magnitude: 15.28

Mon Nov 17 12:42:27.920 2014 aos.info - Adsec 672b-left loading reconstructor.

Mon Nov 17 12:42:29.640 2014 aos.info - Stages offset applied - dx: 0; dy: 0

Mon Nov 17 12:42:29.655 2014 aos.AcquireRef{FLAO}.complete - AcquireRef {FLAO}[577] - dx:0 dy:0 slNull: f1:Filter #0 f2:Filter #0 freq:200 mag:15.277 nBins:4 nModes:10 r0:0 snMode:0 strehl:0 ttMod:6

Mon Nov 17 12:42:29.674 2014 aos.StartAO{FLAO}.started - StartAO {FLAO}[578]

TN:#_124505,_124518
Luci Set: Luci.20141117_0074-0079

12:48 DIMM:0.87"

Tn:#_125033

13:00 DIMM:1.22"

Optimize Gain.

TN:#_130429,_130442,_130649
Luci Set: Luci.20141117_0080-0082,0083 loop open

Mon Nov 17 13:12:53.003 2014 aos.info - Maximum skip reached

Mon Nov 17 13:12:53.015 2014 aos.error - Stopping WFS...

Mon Nov 17 13:12:53.110 2014 aos.info - Updated variable wfsarb.L.FSM_STATE@M_FLAOWFS: AOSet

Mon Nov 17 13:12:53.213 2014 aos.error - Stopping AdSec

Mon Nov 17 13:12:53.229 2014 aos.info - Updated variable AOARB.L.LOOPON: 0

NIGHT NIGHT 13:15

Comments

 

-- %USERSIG{JuanCarlosGuerra - 2014-11-17}%

 
Topic revision: r2 - 17 Nov 2014, JuanCarlosGuerra
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback