CablePiezoBCU5
Known history When Where Who What 20130215 OAA Installed in LgswUnitDx in the YellowChannel. Used to connect PiezoS334617 to BcuNumber2 Know ...
CablePiezoBCU7
Known history When Where Who What 20130605 OAA MB Installed in LgswUnitSx in the YellowChannel. Know issues When What description ...
DayTime20150823
20150823_170000 LgswUnitSx is powered off. Disconnected from the rack. 20150823_180000 LgswUnitDx is completely disassembled apart for WfsCamera and lenslet...
DayTime20150825
Piezo mirrors alignment Alignment of periscopes. The flange has been remachined at LBT for the new periscope mirrors holders. Gola is to get the beam after the pe...
DayTime20150826
LGSW CalUnit alignment After having assembled the WFS up to the periscope we inserted the calibration unit into it. To start aligning the CalUnit the pupil motors...
DayTime20150827
Pockels cells installation A try was done to install insulating foam inside the EM shield boxes. Armaflex foam was provided by MPE in several adhesive sheets. Aft...
DayTime20151019
13:30: we try to calibrate the PatCam to Hexapod movement. We do steps pf 5" around the LGSW FoVs. SX LGSW PatCam to Hexapod IM: 20151019_203311 We determine also...
HowToDefineLgswSubapertures
How to define a subapertures set To create a new subapertures set or just modify the slope computing method you have 2 possibilities: 1 create a new subapertur...
NightTime20151023
17:30: Sx system started from AArb, we try a PockelsCellsTransmission test: TN Plot Map ('20151024_004135','20151024_004258') We start also the ...
Nsa12Number11
Known history When Where Who What 20130320 OAA MB Installed in LgswUnitDx in the YellowChannel X Know issues When What 20130305 ...
Nsa12Number12
Known history When Where Who What 20130320 OAA MB Installed in LgswUnitDx in the YellowChannel Y Know issues When What 20130305 ...
Nsa12Number17
Known history When Where Who What 20130810 OAA MB Received form Newport Know issues When What 20130305 description of issue Cur...
PiezoS334617
Known history When Where Who What 20110413 OAA Delivered from PI Germany with custom mirror from Layertec 20120921 OAA Calibrated us...
PiezoS334618
Known history When Where Who What 20110413 OAA Delivered from PI Germany with custom mirror from Layertec 20130415 OAA Installed in Lg...
r5 - 22 Jul 2013 - 12:03 by TommasoMazzoni
PiezoS334619
Known history When Where Who What 20110413 OAA Delivered from PI Germany with custom mirror from Layertec 20130415 OAA Installed in Lg...
r4 - 22 Jul 2013 - 12:04 by TommasoMazzoni
PockelsCell140
Description This is the new model of PockelsCells rebuild after the OzoneProblem. Known history When Where Who What 20150325 OAA Arrived in Flo...
PockelsCell141
Description This is the new model of PockelsCells rebuild after the OzoneProblem, upgraded to version 2.1 (see PockelsCells) Known history When Where Who ...
PockelsCell143
Description This is the July 2015 model (aka v2.1) of PockelsCells. Known history When Where Who What 201507xx MPE SR Assembled 201508xx ...
PockelsCell144
Description This is the new model of PockelsCells rebuild after the OzoneProblem, upgraded to version 2.1 (see PockelsCells) Known history When Where Who ...
PockelsCell3
Known history When Where Who What 20130313 OAA JZ, SR Installed in LgswUnitDx in YellowChannel 20131122 OAA MB New shield box and conn...
PockelsCell5
Known history When Where Who What 20130808 OAA Arrived in Florence from MPA 20130912 OAA MB, TM Installed in LgswUnitSx in YellowChann...
StepperMotorAdaptorBox
Description Adaptor box is installed inside the LgswUnit. It gets up to 8 motor connected via DB9 connection on the internal side. On the external side it has 2 m...
Number of topics: 22