Backlinks to WfsCamera in ARGOS Web (Search all webs)

Results from ARGOS web retrieved at 01:42 (GMT)

BCU
The BCU is acting as: frame grabber, slope computer, High Voltage Controller for the tip tilt mirrors, collector of slopes from the FLAO BCU and from the TipTiltU...
DayTime20141102
DX LGSW setup 9:00 a.m.: we start up the LGSW. There is a problem with the state machine: in the powered off state the Thors are off and when you restart, passing...
DayTime20150820
Pockels Cells Driver On sx lgsw in the /home/argos/the_pcd folder created pcd_start and pcd_stop to start/stop the PCD accordingly to JZ email of 150612 Zabbix S...
DayTime20150823
20150823_170000 LgswUnitSx is powered off. Disconnected from the rack. 20150823_180000 LgswUnitDx is completely disassembled apart for WfsCamera and lenslet...
DayTime20150827
Pockels cells installation A try was done to install insulating foam inside the EM shield boxes. Armaflex foam was provided by MPE in several adhesive sheets. Aft...
DayTime20170301
14:00: We switch on DX side. DX LGSW pulse generator is working, WFS camera and BCU are working at 970 Hz. 15:00: We pump the SX WFS camera, pressure was 90mbar o...
NEW - 02 Mar 2017 - 00:33 by TommasoMazzoni
DayTime20170302
Power up issues When we power up the SX LGSW the Pupil motor RED Y axis was not homing. We unmount the LGSW panel and we push by hand the stage and at this point ...
NEW - 03 Mar 2017 - 01:58 by TommasoMazzoni
EngPanel
LBT EngPanel LBT EngPanel is a tool developed by Microgate to configure and connect to a BCU unit. The attached software runs on Windows machines, and require the...
HowToMaintainArgos
Device ToDo Frequency month Last Done / Name Comments Full ARGOS system Close loop in daytime with image on LUCI 2 2019 12 04 SW/GR This is a ...
HowToPerformArgosCalibrations
How to perform ARGOS LGSW to ADSEC calibrations This HowTo describes what to do to create a new reconstructor for the AO loop. The description tries to include al...
HowToPowerUpLGSW
This procedure brings up the LGSW system until the WFS is ready for on sky operation i. See FullARGOSStartUpProcedure for prerequisites: chiller, main power, l...
HowToStartPyramidWfs
How to start FLAO Pyramid WFS i. Login as "AOeng" into soul dxwfs (or soul sxwfs) and check if the WFS processes are running with w_check.If that is the case, ...
HowToStartSoftware
How to start Software There are multiple ways to start up the software and depending on situation one or the other is more appropriate. The ARGOS software has als...
LabGUI
LabGUI This is the main engineering GUI that allows to control the full LgswSystem hardware. #StartLabGUI How to start the LabGUI i. Login on the workstation:...
LgswAlignmentTools
Description It is a set of utility tools needed to align the LgswSystem and the LgswDichroicSystem at the telescope. All the material fits in a gray box (used for...
NewportNSA12StepperMotors
Description These motors are used to adjust the pupil position in the LgswUnit. They are customized: the connector has been replaced with a DB9 to plug into the S...
NotableSnapshots
A collection of notable snapshots, useful for checking analyzer algorithms, producing images for presentations and so on. Tag Diary page Notes 20150502_...
r2 - 02 Nov 2015 - 15:24 by TommasoMazzoni
RegulatedCoolingLine
Definition It is a cooling circuit in which the cooling fluid temperature never goes below 6°C and follows the ambient temperature when it is warmer than 6°C. The...
ThingsThatIDontUnderstand0006
Occurence When Notes 20130325 first noted Description Sequence: a,E,o,c = Camera is cooled and working, and we get frames. We stop during for a coupl...
ThingsThatIDontUnderstand0008
Occurence When notes 20130820 Description We got an error with opcode 202 on BcuNumber3 when writing into DSP memory during frame grabbing. This could...
ThorSensor
Description Sensors with Sensirion SHT21 and RJ connector assembled by Wavecomm. There are several kinds of probes: 1 The ones named THxx with xx greater than ...
TroubleShoot
Troubleshoot ARGOS Troubleshoot by states More recover procedures at: HowToRecoverArgos When Symptom What to do Notes Cold start PowerOn fails, sev...
WfsCamera1
Known history When Where Who What 20130215 OAA JZ, GOX Delivered 20131011 OAA GOX Upgrade of the electronic panel on the external side...
WfsCamera2
Known history When Where Who What 20130506 OAA JZ, GOX Delivered 20131011 OAA GOX Upgrade of the electronic panel on the external side...
WfsCamera3
Known history When Where Who What 20140130 OAA GOX Installed in LgswUnitSx. 20150209 OAA MB, GOX back to MPE for servicing. 201510...
r6 - 12 Jan 2016 - 15:51 by GillesOrban
WfsCameraElectronicsRack
Description A device in the ElectronicRackLgsw, composed by PcKontron, Sequencer, TemperatureController and PowerSupply Documentation attach and describe datashe...
r4 - 26 Aug 2015 - 09:09 by GillesOrban
WfsCameraElectronicsRack1
Known history When Where Who What 20130215 OAA JZ, GOX Delivered 20140114 OAA MB, JZ, TM Removed from LgswRack1. 20140130 OAA ...
WfsCameraElectronicsRack2
Known history When Where Who What 20130506 OAA JZ, GOX Delivered 20140114 OAA MB, JZ, TM Removed from LgswRack2. Installed on LgswRac...
NEW - 21 Jan 2014 - 11:11 by TommasoMazzoni
WfsCameraElectronicsRack3
Known history When Where Who What 20140130 OAA GOX Installed in LgswRack2. 20210204 LBT GR Replaced failing PEC Temperature Controller...
WfsCameraPump
This is the pump that is needed to vacuum the WfsCamera Checking camera housing pressure and pumping it out Reading the pressure * The software pressure measu...
WfsCameraPump1
How To Use it See WfsCamera Known history When Where Who What 20160511 LBT TM, SR Used to pump WfsCamera1 20160511 LBT LB Stored in A...
WfsCameraToRackCables
Description This is a big boundle of cables connecting the WfsCamera to its electronic inside the ElectronicRackLgsw Documentation attach and describe datasheets...
r2 - 26 Aug 2015 - 09:04 by GillesOrban
WfsCameraToRackCables01
Known history When Where Who What 20130215 Know issues When What 20130305 description of issue Current known config IP, firmwar...
WfsCameraToRackCables02
Known history When Where Who What 20130215 Know issues When What 20130305 description of issue Current known config IP, firmwar...
WfsCameraToRackCables03
Known history When Where Who What 20130215 MPE GOX This is a spare cables boundle, it is missing full labelling and protective socket Know is...
Number of topics: 35
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback