50 recent changes in ARGOS Web retrieved at 21:12 (GMT)

PockelsCellsTransmission
History of test When Where Devices Notes Test log 20140518 LBT PockelsCell2, PockelsCell3, PockelsCell4 Ozone problem discover PockelsCellTe...
WebHome
Welcome to the ARGOS Laser Guide Star wiki pages This wiki collects all the information related to the 2 ARGOS laser guide star systems. It is written for the use...
CalSourceDiodes
Image of the Calibrations source (diodes0 in the WFS.h Main.JuanCarlosGuerra 10 Sep 2021
HowToRemoveComa
There are 2 ways to remove coma by moving the AdSec hexapod: 1 using the ARGOS terminal 1 using TCS GUI How to remove coma using the ARGOS terminal i. O...
TroubleShoot
Troubleshoot ARGOS Troubleshoot by states More recover procedures at: HowToRecoverArgos When Symptom What to do Notes Cold start PowerOn fails, sev...
HowToAddANewModalBasis
How to Add a New Modal Basis When the ASM is re calibrated a new modal basis is created and saved in the ASM computer.We need to produce a local copy of the modal...
HowToShutdownArgos
How to shutdown and power off ARGOS properly At the end of a night or at the end of a day work shutdown ARGOS by: * Press button "Shutdown". * Daytime work...
WfsCamera2
Known history When Where Who What 20130506 OAA JZ, GOX Delivered 20131011 OAA GOX Upgrade of the electronic panel on the external side...
WfsCamera1
Known history When Where Who What 20130215 OAA JZ, GOX Delivered 20131011 OAA GOX Upgrade of the electronic panel on the external side...
FullARGOSStartUpProcedure
Full ARGOS Start up procedure This procedure describes how to start up ARGOS from scratch. After summer shutdown or a longer periode of non use the system might h...
TemperatureMonitor6
Known history When Where Who What 20130930 Delivered to OAA by WaveComm 20131001 OAA MB Configured as spare unit for LgswUnitSx 20...
HowToAlignCalibrationUnit
How to align the calibration unit Information on the original alignment can be found here. This is not a routine maintenance procedure.The procedure should only ...
HowToSetupHexapodForCalibrationUnit
This topic contains the history of best hexapod position to align the CalUnitSystem to LUCI and LGSW * X, Y, Z, Rx, Ry, Rz are the hexapod absolute position ...
ComaCorrection
See also HowToRemoveComa I got instructions to apply a coma correction movement on the Hexapod from J. C. Guerra by e mail (8 May 2014 00:42): To apply a coma of...
HowToSetupARGOSForCalibrations
How To Setup ARGOS for AO calibrations Pre requisits: * Coordinate telescope access with Telescope Manager and mail to telescopework * Telescope must be ...
AvtNumber2
Known history When Where Who What 20110228 OAA Delivered 20150304 OAA MB Removed from LgswUnitSx. Probably half broken ethernet port. ...
AvtCamera
Description The 3 patrol camera units in each LgswUnit are based on AVT GC1350 cameras. The 12V power supply is installed in the MoCon. The ethernet cable is conn...
HowToStartSoftware
How to start Software There are multiple ways to start up the software and depending on situation one or the other is more appropriate. The ARGOS software has als...
HowToUseTheFiberSwitch
Usage of the Fastlink Fiber Switch The Fiber Switch is a device installed in the Treehouse to configure FastLink fibers for ARGOS operation. This one superseed ...
BcuNumber3
Known history When Where Who What 20130716 OAA BcuNumber3 received from MPE 20130730 OAA MB Exchanged with BcuNumber1 in LgswRack2 ...
BcuNumber2
Known history When Where Who What 20130215 delivered to Arcetri in the DX rack delivery 20130220 OAA LB Flashed new Logic version to s...
BcuNumber1
Known history When Where Who What 201204xx OAA BCU used by HD SW group to develop the software is shipped to Arcetri 20120412 OAA OAA ...
WfsCameraElectronicsRack3
Known history When Where Who What 20140130 OAA GOX Installed in LgswRack2. 20210204 LBT GR Replaced failing PEC Temperature Controller...
WfsCamera
Description A WfsCamera device is the fast speed camera of the SH WFS unit. It is installed at the end of the LgswUnit. This topic refers only to the camera head....
LgswDichroicSystem
Description Documentation Design document: Low_inc_dichroic_report_v1.7.pdf For informations about the motor controllers hosted in the electronic rack see Dichro...
WhiteLightSource
Description The white light source is a subrack unit containing two Ocean Optics HL 2000 HP 232 halogen light sources and a Moxa NPort 5400 serial device server. ...
HowToMaintainArgos
Device ToDo Frequency month Last Done / Name Comments Full ARGOS system Close loop in daytime with image on LUCI 2 2019 12 04 SW/GR This is a ...
DiaryRunxx
Daytime work to attempt to generate new reconstructors for DX KL_v27. Log 20191030 (Wednesday) Shane and I attempted to generate the ARGOS DX reconstructors to...
HowToStartHousekeepingOnly
How to start only the Housekeeping module from scratch (e.g. during Summer Shutdown when ARGOS is completely off) 1 Connect to dx lalas via VNC: HowToLogInAnd...
HowToRecoverArgos
How to recover ARGOS Procedure to recover from BCU crash Usual symptom: CCD Viewer does not update 1 Set LAS and LAN in simulation (Arbitrator GUI, Tab: Exper...
EngPanel
LBT EngPanel LBT EngPanel is a tool developed by Microgate to configure and connect to a BCU unit. The attached software runs on Windows machines, and require the...
WfsCameraPump
This is the pump that is needed to vacuum the WfsCamera Checking camera housing pressure and pumping it out Reading the pressure * The software pressure measu...
DayTime20200609
ARGOS daytime testing 2020 06 09 Participants: Lorenzo B., Marco B., Wolfgang G., Gustavo R., Carl H., Shane W. Setup AdSec set up for UAO (default is SOUL): 1) ...
Commissioning
Commissioning run diaries Run 1st day Run ID Description 20111128 Run # 1 Nov 2011 Installation of dichroic interfaces 20130614 Run Installati...
DiaryRun23
There are issues with the SX. Why? When What Log Notes 20200310 SX Remote Daytime DayTime20200310 20200609 SX Remote Daytime DayTime2020...
HowToReplaceCircuitBreakers
Replacing circuit breakers on the ARGOS Remote Power Control unit The Remote Power Control unit is located inside LSPRackSx. The attached document (by Julian Zieg...
DayTime20200310
Setup Remember to configure AdSec for UAO (that means it accepts 1600 slopes as it was in the good old days). Now the default is for SOUL with 2400 slopes Doug kn...
HowToConnectToARGOSWorkstationAtLBT
The following instructions apply if you are connecting from outside the telescope network. If you are at the telescope just follow HowToLogInAndConnectToVNC Logi...
HowToPerformArgosCalibrations
How to perform ARGOS LGSW to ADSEC calibrations This HowTo describes what to do to create a new reconstructor for the AO loop. The description tries to include al...
HowToCreateASingleLgswReconstructor
!!!! Keep track of your work !!!! !!!! Remember to keep track of the recorded IMs and all RECs built into the following pages: * DXAoLoopCalibrations * SXAo...
HowToStartPyramidWfs
How to start FLAO Pyramid WFS i. Login as "AOeng" into soul dxwfs (or soul sxwfs) and check if the WFS processes are running with w_check.If that is the case, ...
PockelsCellDriver6
Known history When Where Who What 20150827 LBT JZ Unboxed and installed on LgswUnitDx 20150831 LBT JZ Stored on top of ArgosCabinet1 a...
PockelsCellDriver5
Known history When Where Who What 20150815 LBT MB, LB Unboxed and installed on LgswUnitSx 20150831 LBT JZ Stored on top of ArgosCabine...
SXAoLoopCalibrations
Summary of AO loop calibrations for the ArgosSystemSx Table below resumes the latest combined reconstructors built and tested in daytime, this table represents th...
CalUnitSystem
The CalUnitSystem (or Calibration Unit) is the ARGOS source used for AO calibration in day time. It creates 3 beams that mimics the 3 LGS beams: 532nm narrow band...
UsefulLoginInfo
Login credentials user host pwd hint argos argos dx easy one with numbers argos argos sx easy one with numbers argos dx lalas easy o...
HowToCheckVibrationCompensationAccelerometers
Bad connected accelerometers can lead to faulty behaviour of the vibration compensation system. This method can be used to check for problems with the acceleromet...
AoLoopDisturbances
Summary of AO loop disturbances for the ArgosSystem Using the ARGOS CalUnit the number of reflections on the secondary is one. Useful link: HowToConvertDisturbanc...
HowToGetInformationAboutOldCalibration
How to Get Information about Old Calibration The starting point is the tag of a combined reconstructor. All the information about the reconstructor is inside the ...
HowToPerformArgosAoLoopInDayTime
How to perform ARGOS closed loop in daytime This HowTo explains how to close an AO loop with the ARGOS system in daytime using the CalUnit as reference source. Th...