When | Symptom | What to do | Notes |
---|---|---|---|
Cold start | PowerOn fails, several devices are still unreachable (e.g. the LGSW rack is off). The Remote Power Switch (in las lab GUI) is unresponsive | HowToPowerCycleTheRemotePowerSwitch | |
LGS acquired | LGS acquisition is unstable. Sporadic, large oscillations of the LGSW image on the patrol cameras. | HowToCheckVibrationCompensationAccelerometers |
When | Where | What![]() |
Why | Solution |
---|---|---|---|---|
With POWERING_UP | DX | time out exception | CCD is taking to long to cool down | press OK, and in case it goes back to UNKNOWN press again POWER_UP |
With POWERING_UP | ANY | time out exception | various reasons | press OK, press again POWER_UP |
With POWERING_UP | ANY | ERROR 'None Type' object has no attributes 'event Power up' | AArb is not connected with AOS | enable AArb in AOS GUI |
With POWERING_UP | SX | back to UNKNOWN | blue patrol camera does not connect when cold | press again power_up |
With ANY | ANY | Any ERROR with 'None Type' | This is an indication, that connection to the database is lost, either TaN or AOS. | For AOS, enable AArb in AOS GUI or restart ARGOS arbitrator. |
With PREPARING | ANY | ... Error in key managment... | Truth sensor process died. | Go FLAO "System process" GUI: check and restart. |
With PREPARING | ANY | NOTICE: ...."Timeout waiting for slopecompctrl.R.CONFIG.CUR (-5001) TIMEOUT_ERROR".... | FLAO slope computer error | Go FLAO "System process" GUI check and restart:
|
Device | What | How to diagnose | Solution | |
---|---|---|---|---|
WfsCamera | Is not switched on. | In LGSW Lab GUI, 'WFS.PnCCDStatus' is 'Unknown', but camera is cold and everything in 'WFS.Debug Statuses' looks ok | In 'WFS.Parameters Settings' click on "Power ON CCD" | |
WfsCamera | Fails at Power Up with "Cannot turn cooling on. Check statuses." | In LGSW Lab GUI, WFS tab, check "Debug Statuses" tab. | If any of the PSU Statuses is red, power off the cabinet for ~10 minutes (to ensure PSU is completely off). Power on and try again. IT#7960. |
What | How to diagnose | Solution |
---|---|---|
Movements not as expected | LAT images, log files of LM (~/log/?X.LAN.LM1.BASDARD.log or ?X.LAN.CONTROLLER.log), check absolute encoder in argos_?x_lm1_tripod_gui !!never ever use another GUI for moving the LM1!! Look into Zabbix screen "?X LM1 devices" |
depends Use: LAN controller GUI to set to nominal postion (only in state "Ready to Observe") Tripod GUI to check absolute encoders and move LM1 |
What | How to diagnose | Solution |
---|---|---|
LAN fails to complete Power On | Check if NI_BOX is reachable | If NI_BOX is not reachable, go to the corresponding LLP cabinet and press the power switch (lower left of the unit) to the "STANDBY" position and then back to "ON". See IT#8411 |