LUCI work until 5:00 UT

Telescope to horizon
Fixing SX LM1 A1 absolute encoder. Reset to 0.
Unintentionally done first at DX, therefor DX and SX LM A1 encoder were reset at negative limit.It looks like the DX reset was not that good. With high velocity one can still go into the negative regime.

07:10 Starting tests with LUCI to measure AO influence on slit accuracy.
TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161025_074710 0.25, 0, 0 T 73.3233 39.3676 20161013_160000 -1 T F
20161025_080306 0.25,0.05, 0 T 74.6924 31.9345 20161013_160000 -1 T F
20161025_080503 0.25, 0, 0 T 82.4953 291.81 20161013_160000 -1 T F
20161025_080605 0.25, 0, 0 T 78.9318 368.167 20161013_160000 -1 F F
20161025_080652 0.25, 0, 0 T 84.9846 364.165 20161013_160000 -1 F F
20161025_080752 0.25, 0, 0 T 99.2177 360.172 20161013_160000 -1 F F
20161025_080852 0.25, 0, 0 T 96.8839 357.52 20161013_160000 -1 F F
20161025_080921 0.25, 0, 0 T 65.1496 357.06 20161013_160000 -1 F F
20161025_081006 0.25, 0, 0 T 72.8079 357.516 20161013_160000 -1 F F
20161025_081107 0.25, 0, 0 T 48.9339 359.289 20161013_160000 -1 F F
20161025_081158 0.25, 0, 0 T 52.6761 365.029 20161013_160000 -1 F F
20161025_081241 0.25, 0, 0 T 48.6948 356.727 20161013_160000 -1 F F
20161025_081401 0.25, 0, 0 T 44.552 364.483 20161013_160000 -1 F F
20161025_081516 0.25, 0, 0 T 46.3897 355.804 20161013_160000 -1 F F
20161025_081604 0.25, 0, 0 T 43.6266 361.803 20161013_160000 -1 F F
20161025_081721 0.25, 0, 0 T 44.0531 364.699 20161013_160000 -1 F F
20161025_083341 0.25,0.1, 0 T 72.077 41.8394 20160313_063600 -1 F F
20161025_083513 0.25,0.1, 0 T 74.8705 51.3993 20160313_063600 -1 F F
20161025_083633 0.25,0.1, 0 T 82.6669 42.9357 20160313_063600 -1 F F
20161025_083739 0.25,0.1, 0 T 67.981 42.3935 20160313_063600 -1 F F
20161025_083855 0.25,0.1, 0 T 60.7151 41.7194 20160313_063600 -1 F F
20161025_084037 0.25,0.1, 0 T 90.0655 44.3545 20160313_063600 -1 F F
20161025_084141 0.25,0.1, 0 T 91.5668 44.0987 20160313_063600 -1 F F
20161025_084239 0.25,0.1, 0 T 83.6935 42.6741 20160313_063600 -1 F F
20161025_084350 0.25,0.1, 0 T 82.7228 42.2754 20160313_063600 -1 F F
20161025_084548 0.25,0.1, 0 T 74.9063 41.9961 20160313_063600 -1 F F
20161025_084801 0.25,0.1, 0 T 72.2825 42.0196 20160313_063600 -1 F F
20161025_084909 0.25,0.1, 0 T 62.5926 41.9079 20160313_063600 -1 F F
20161025_085024 0.25,0.1, 0 T 77.1421 40.6019 20160313_063600 -1 F F
20161025_085126 0.25,0.1, 0 T 75.0393 42.4455 20160313_063600 -1 F F
20161025_085232 0.25,0.1, 0 T 76.0315 42.4883 20160313_063600 -1 F F
20161025_085342 0.25,0.1, 0 T 82.6579 42.4817 20160313_063600 -1 F F
20161025_085438 0.25,0.1, 0 T 64.8088 42.2016 20160313_063600 -1 F F
20161025_085600 0.25,0.1, 0 T 72.0797 42.3744 20160313_063600 -1 F F
20161025_085742 0.25,0.1, 0 T 76.6595 43.2753 20160313_063600 -1 F F
Never opened tonight.

-- WolfgangGaessler - 25 Oct 2016
Topic revision: r5 - 16 Nov 2016, MarcoBonaglia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback