10:00 LAT/05:00 UT Handover from LUCI/AO
  • Lorenzo + Gustavo where switching fibers.
  • SX dichroic got stuck while authorization.
  • Authorization failed on telescope side, redo succeded but moved out again DX dichroic.
  • BCU had to be restarted.
LRLL54361_20161023.pdf

NGC2419_20161023.pdf

05:10 UT pointing preset
05:15 UT starting with collimation on 8_o_clock arc 00:22:40:92 +14:31:10.4
05:20 UT preset after longer setup of the FLAO and BCU on SX
05:23 airplain during acquisition
05:26 realiesed shell not set
05:27 shell is set
05:30 closing loop
05:31 tuned loop start with an offset, first measurement below 2pix
05:35 first mask image
05:37 1st alignment
05:43 2nd alignment with 0.2; 0,2; 0
05:48 start exposure
06:04 opened loop because of LM1
06.05 opened loop because of LM1
06:08 optimization pause
06:09 satellite pause
06:10 laser back, loop optimization 1.5 TT 0.5 low 0.35 high gain
optimizing on sky and taking spectra
Pupil to laser mapping
(see Lorenzos notes)
07:59 Maffei2 longslit
09:35 LRLL54361, imaging and longslit
12:49 going to NGC2419 imaging
13:50 starting flatfields

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161023_055746 1.5,0.5,0.4 T 145.131 122.794 20161013_160000 -1 T F
20161023_063325 1.5,0.5,0.35 T 127.137 130.83 20161013_160000 0.807026 T F
20161023_063337 1.5,0.5,0.35 T 144.136 131.568 20161013_160000 0.83964 T F
20161023_063347 1.5,0.5,0.35 T 161.903 111.943 20161013_160000 0.848563 T F
20161023_071459 1.5,0.45,0.35 T 120.413 112.258 20161013_160000 1.01068 T F
20161023_071546 1.5,0.45,0.35 T 122.895 104.84 20161013_160000 0.97773 T F
20161023_072548 1.5,0.45,0.35 T 149.285 116.939 20161013_160000 0.785373 T F
20161023_072913 1.5,0.45,0.35 T 125.944 109.206 20161013_160000 0.812104 T F
20161023_072954 1.5,0.45,0.35 T 146.228 98.2273 20161013_160000 0.818563 T F
20161023_100838 1.5,0.45,0.35 T 168.359 108.197 20161013_160000 -1 T F
20161023_100851 1.5,0.45,0.35 T 174.482 109.105 20161013_160000 -1 T F
20161023_100941 1.5,0.45,0.35 T 139.973 135.94 20161013_160000 -1 T F
20161023_101007 2.5,0.45,0.35 T 169.451 127.835 20161013_160000 -1 T F
20161023_101017 2.5,0.45,0.35 T 172.714 134.068 20161013_160000 -1 T F
20161023_103340 2,0.45,0.35 T 145.834 111.711 20161013_160000 -1 T F
20161023_103536 2.5,0.45,0.35 T 163.193 144.076 20161013_160000 -1 T F
20161023_112816 2.5,0.45,0.35 T 180.78 116.859 20161013_160000 -1 T F
20161023_121124 2.5,0.45,0.35 T 184.406 277.869 20161013_160000 -1 T F
Topic revision: r7 - 04 Dec 2016, MarcoBonaglia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback