19:00 - 22:00: time allocated to LUCI/AO

G111.25

  • Problem with the sign in the stages directions signs, solved
  • Pointing reference position for FLAO is [-73.5; -49.0] mm that is wrong, we set it back to [-77.5; -50.0] mm

Seeing is very bad we move to an easier target

1180-0032995

23:30: seeing still >2"

  • Problem when sending FLAO slopes the ARGOS BCU crashes. Solved: the sl_fl_cmd_argos.txt file was missing in the new calib folder of Centos6 machine

2:30: we give it up, too many errors in the UAO code, we revert to the Centos5 version.

1282-0122482

Still problems with AdSecSx, we move to fast guiding test...