18:30: begin of operations we point to:

HESS_J1943p213

Beam shaping: corrector at 255 and focus stage at -75k steps.

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_020540 1.5,0.5,0.4 T 129.097 262.248 20161013_160000 0.969304 T F
20161020_020619 1.5,0.5,0.4 T 124.97 299.874 20161013_160000 0.960986 T F
20161020_020739 0.15, 0, 0 T 109.793 592.468 20161013_160000 1.12191 T F
20161020_020819 2,0.5,0.4 T 134.274 291.025 20161013_160000 1.0678 T F
20161020_020859 1,0.5,0.4 T 140.917 311.844 20161013_160000 1.01744 T F
20161020_020919 2,0.5,0.4 T 112.516 320.171 20161013_160000 1.07319 T F
20161020_022251 2,0.5,0.4 T 137.599 287.105 20161013_160000 0.965026 T F
20161020_022306 2,0.5,0.4 T 127.696 324.644 20161013_160000 0.985603 T F
20161020_022351 2,0.5,0.4 T 186.671 586.195 20161013_160000 1.03744 T F
20161020_024335 1.5,0.5,0.4 T 114.447 147.643 20161013_160000 0.964791 T F Vib comp ON
20161020_024352 1.5,0.5,0.4 T 119.77 122.99 20161013_160000 0.953372 T F
20161020_024418 1.5,0.5,0.4 T 115.26 151.946 20161013_160000 1.00893 T F
20161020_024441 1.5,0.5,0.4 T 110.199 254.422 20161013_160000 1.04699 T F Vib comp OFF
20161020_024450 1.5,0.5,0.4 T 113.974 255.105 20161013_160000 1.03322 T F
20161020_024550 1.5,0.5,0.4 T 118.034 131.043 20161013_160000 1.04555 T F Vib comp ON
20161020_025218 1.5,0.5,0.4 T 106.133 115.458 20161013_160000 1.07711 T F
20161020_025301 0, 0, 0 T 102.577 446.493 20161013_160000 0.917373 T F
20161020_025345 1.5,0.5,0.4 T 104.541 123.614 20161013_160000 1.10096 T F
20161020_025357 1.5,0.5,0.4 T 111.837 133.541 20161013_160000 1.09395 T F

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_032237 1.5,0.5,0.4 T 106.988 151.007 20161013_160000 -1 T F
20161020_032311 1.5,0.5,0.4 T 98.0725 143.87 20161013_160000 0.938329 T F Auto
20161020_032421 1.5,0.5,0.4 T 82.2968 136.526 20161013_160000 0.940989 T F Auto
20161020_032530 1.5,0.5,0.4 T 93.0461 128.959 20161013_160000 1.00095 T F Auto
20161020_032740 1.5,0.05,0.04 T 89.7969 115.008 20161013_160000 0.974949 T F Auto
20161020_032849 0, 0, 0 T 2062.55 693.712 20161013_160000 0.989551 T F Auto
20161020_032958 1.5,0.5,0.4 T 89.8078 147.708 20161013_160000 1.05843 T F Auto
20161020_033108 1.5,0.5,0.4 T 87.9308 167.545 20161013_160000 1.07701 T F Auto
20161020_033217 1.5,0.5,0.4 T 84.4423 135.962 20161013_160000 1.10713 T F Auto
20161020_033332 1.5,0.6,0.4 T 86.0614 143.921 20161013_160000 1.03638 T F
20161020_033342 1.5,0.6,0.5 T 88.5628 128.287 20161013_160000 1.0321 T F
20161020_034238 1.5,0.5,0.4 T 79.6228 144.557 20161013_160000 1.34764 T F
20161020_020540_SlopeOffsetVsTime.jpg

8_o_clock

21:00: we move to this target, it's super windy, it's very difficult to keep the loop closed... We start with imaging:

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_042917 4, 0,1.38778e-17 T 126.509 932.882 20161013_160000 1.28002 T F
20161020_045611 3,0.2,1.38778e-17 T 122.607 230.702 20161013_160000 1.48483 T F
20161020_045638 3,0.2,1.38778e-17 T 109.079 282.967 20161013_160000 1.40292 T F
20161020_045703 3,0.2,1.38778e-17 T 139.278 265.391 20161013_160000 1.36899 T F
20161020_045933 3,0.2,1.38778e-17 T 147.969 245.916 20161013_160000 1.26681 T F
20161020_050300 2.55,0.2, 0 T 132.499 222.441 20161013_160000 1.23988 T F
20161020_050505 2.55,0.2,0.1 T 145.279 139.091 20161013_160000 1.25685 T F
20161020_050703 2.55,0.2,0.1 T 185.973 131.721 20161013_160000 1.10401 T F
20161020_050748 2.55,0.25,0.1 T 188.922 131.857 20161013_160000 1.09278 T F
20161020_051043 0, 0, 0 T 14082.6 597.384 20161013_160000 1.00321 T F
20161020_051120 2.55,0.25,0.15 T 200.38 144.421 20161013_160000 -1 T F
20161020_051441 2.55,0.25,0.15 T 158.576 136.144 20161013_160000 1.06097 T F
20161020_051526 2.55,0.25,0.15 T 149.882 154.095 20161013_160000 1.1727 T F
Then we preset for spectroscopy:

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_054132 2.55,0.2,0.1 T 149.604 148.141 20161013_160000 0.980754 T F
20161020_054209 2.55,0.3,0.2 T 153.494 155.572 20161013_160000 1.12341 T F
20161020_054252 2.55,0.3,0.2 T 167.705 175.402 20161013_160000 1.18769 T F
20161020_054424 2.55,0.35,0.2 T 157.059 151.263 20161013_160000 1.09494 T F
20161020_055123 2.55,0.5,0.4 T 187.619 143.708 20161013_160000 1.0369 T F
20161020_055134 2.55,0.5,0.4 F 156.368 1356.81 20161013_160000 1.01649 T F
20161020_055348 2.55,0.5,0.4 T 197.639 159.174 20161013_160000 -1 T F
20161020_055429 2.55,0.5,0.4 T 192.687 136.304 20161013_160000 -1 T F
20161020_055623 2.55,0.5,0.4 T 200.084 144.256 20161013_160000 0.989419 T F
20161020_055900 2.55,0.5,0.4 T 208.616 163.56 20161013_160000 1.00697 T F
20161020_060032 2.55,0.5,0.4 T 154.237 156.61 20161013_160000 0.91717 T F Auto
20161020_060141 2.55,0.5,0.4 T 200.632 143.318 20161013_160000 0.984929 T F Auto
20161020_060251 2.55,0.5,0.4 T 162.284 131.115 20161013_160000 1.05879 T F Auto
20161020_060400 2.55,0.5,0.4 T 161.614 150.027 20161013_160000 1.04112 T F Auto
20161020_060509 2.55,0.5,0.4 T 126.546 151.177 20161013_160000 1.07735 T F Auto
20161020_060618 2.55,0.5,0.4 T 157.454 146.309 20161013_160000 0.998021 T F Auto
20161020_060728 2.55,0.5,0.4 T 184.807 160.78 20161013_160000 0.978406 T F Auto
20161020_060837 2.55,0.5,0.4 T 408.848 153.307 20161013_160000 1.02161 T F Auto
20161020_061047 2.55,0.5,0.4 T 140.286 135.175 20161013_160000 1.04102 T F Auto
20161020_061156 0, 0, 0 T NA NA NA NA T F Auto
20161020_061314 2.55,0.5,0.4 T 137.481 153.62 20161013_160000 1.01584 T F Auto
20161020_061423 2.55,0.5,0.4 T 168.887 178.708 20161013_160000 0.972626 T F Auto
20161020_061533 2.55,0.5,0.4 T 197.715 142.463 20161013_160000 0.893159 T F Auto
20161020_061642 2.55,0.5,0.4 T 174.629 181.349 20161013_160000 1.00685 T F Auto
20161020_062052 2.55,3.46945e-18, 0 T 109.171 780.769 20161013_160000 1.00111 F F Auto
20161020_062201 2.55,0.35,0.2 T 172.58 172.608 20161013_160000 1.00062 T F Auto
20161020_062310 2.55,0.35,0.2 T 143.632 145.526 20161013_160000 1.08078 T F Auto
20161020_062420 2.55,0.35,0.2 T 134.727 153.897 20161013_160000 -1 T F Auto
20161020_062530 2.55,0.35,0.2 T 188.093 156.877 20161013_160000 -1 T F Auto
20161020_062639 2.55,0.35,0.2 F nan 453.221 20161013_160000 -1 T F Auto

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_064456 2.55,0.35,0.2 T 231.911 179.778 20161013_160000 -1 T F
20161020_064519 2.55,0.35,0.2 T 212.096 178.269 20161013_160000 -1 T F

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_072021 1.75,0.3,0.2 T 160.208 355.135 20161013_160000 0.788894 T F
20161020_072046 1.75,0.3,0.2 T 167.862 394.61 20161013_160000 0.793322 T F
20161020_042917_SlopeOffsetVsTime.jpg

00:30: midnight bug, we must restart all the software, even AOS... We take about 1h to restart with observations...

  • AdSecSx disk full: the mirror does not accept any command from AARB: rec, gain, etc are not loaded

Maffei 2

1:30: we move to this target, still difficult to close the loop, blue and red pupils jump on left subap

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161020_090843 1.5,0.25,1.38778e-17 T 104.16 213.884 20161013_160000 1.25183 T F Auto
20161020_090953 1.5,0.25,0.05 T 98.4481 133.728 20161013_160000 1.20559 T F Auto
20161020_091102 1.5,0.35,0.15 T 93.3439 118.607 20161013_160000 1.14879 T F Auto
20161020_091211 1.5,0.35,0.15 F 108.17 756.972 20161013_160000 1.26204 T F Auto
20161020_091319 0.375, 0, 0 T 99.7965 502.834 20161013_160000 1.16911 F F Auto
20161020_091428 1.5,0.35,0.15 T 104.03 112.001 20161013_160000 0.959008 T F Auto
20161020_091537 2.5,0.35,0.15 T 94.925 169.894 20161013_160000 1.08903 T F Auto
20161020_093428 2,0.2,1.38778e-17 T 106.522 182.481 20161013_160000 0.980423 T F
20161020_093449 2,0.3,0.15 T 99.9207 145.9 20161013_160000 0.911576 T F
20161020_093532 2,0.4,0.2 T 100.494 131.892 20161013_160000 0.905784 T F Auto
20161020_093642 2,0.4,0.2 T 102.933 144.733 20161013_160000 0.940651 T F Auto
20161020_093751 2,0.4,0.2 T 96.9623 139.971 20161013_160000 1.04196 T F Auto
20161020_093901 2,0.4,0.2 T 103.265 148.229 20161013_160000 1.01711 T F Auto
20161020_094011 0, 0, 0 T 265.916 413.426 20161013_160000 0.963368 T F Auto
20161020_094120 2,0.4,0.2 T 117.34 166.176 20161013_160000 0.887776 T F Auto
20161020_094230 0, 0, 0 T 20457.8 337.584 20161013_160000 -1 F F Auto
20161020_094338 0, 0, 0 T 19320.5 639.889 20161013_160000 -1 F F Auto
20161020_094847 2,0.4,0.2 T 115.619 132.134 20161013_160000 -1 T F Auto
20161020_094957 2,0.4,0.2 T 104.455 175.124 20161013_160000 0.946504 T F Auto
20161020_095106 2,0.4,0.2 T 113.707 141.878 20161013_160000 1.00718 T F Auto
20161020_095215 2,0.4,0.2 T 94.6185 119.47 20161013_160000 0.942059 T F Auto
20161020_095324 0, 0, 0 T 5210.6 450.754 20161013_160000 0.894167 F F Auto
20161020_095434 0, 0, 0 T 14671.4 817.717 20161013_160000 -1 F F Auto
20161020_095543 0, 0, 0 T 17458.1 308.794 20161013_160000 0.931219 T F Auto
20161020_095652 0, 0, 0 T 9961.76 483.327 20161013_160000 0.959236 T F Auto
20161020_090843_SlopeOffsetVsTime.jpg

3:00: handover to LUCI/AO