Late opening for technical reasons

SDSSJ1110+6459

04:10UT Loop closed

04:24UT We keep on being visited by airplanes

04:45UT Un po di snapshot al passare delle nuvole

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160523_044417 0.85,0.35,0.25 T 188.726 147.178 20151212_233600 0.844669 T F
20160523_044431 0.85,0.35,0.25 T 172.76 145.661 20151212_233600 0.843394 T F
20160523_044443 0.85,0.35,0.25 T 173.633 142.509 20151212_233600 0.813906 T F
20160523_044638 0.85,0.35,0.25 T 170.671 132.914 20151212_233600 0.95998 T F
20160523_044652 0.85,0.35,0.25 T 190.955 115.652 20151212_233600 0.965546 T F
20160523_044708 0.85,0.35,0.25 T 173.179 127.986 20151212_233600 0.975896 T F
20160523_045811 1.2,0.35,0.25 T 211.401 139.262 20151212_233600 0.927661 T F
20160523_045820 1.2,0.35,0.25 T 221.057 145.488 20151212_233600 0.898247 T F
20160523_045830 1.2,0.35,0.25 T 205.233 157.563 20151212_233600 0.908297 T F
20160523_050313 1.2,0.35,0.25 T 155.506 124.251 20151212_233600 0.930392 T F
20160523_050323 1.2,0.35,0.25 T 200.24 133.159 20151212_233600 0.923511 T F
20160523_053816 1,0.3,0.25 T 171.301 143.603 20151212_233600 0.91955 T F
20160523_053826 1,0.3,0.25 T 208.554 515.393 20151212_233600 0.926928 T F

05:54UT End 45Deg elevation

M51

06:00 Preset binoculare

Non funge, va bene sui piccoli offset, ma non sui grandi

07:00 Preset monoculare

Nuvole, comunque si seguita a integrare per Iskren

08:01 fine dell'osservazione

M101

08:09 preset

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160523_082805 0.95,0.3,0.25 T 72.804 154.423 20151212_233600 -1 T F
20160523_082836 0.95,0.3,0.25 T 75.1838 193.364 20151212_233600 -1 T F
20160523_082849 0.95,0.3,0.25 T 83.5671 167.323 20151212_233600 -1 T F

08:41 end

SDSS J1723+3411

08:45 preset

seeing molto schifoso, si apre in continuazione

C'e' un problema nel meccanismo degli offset che non funziona e ci fa perdere la NGS. Caso: LUCI manda offset e noi non siamo in condizioni di accettarlo (tipo non siamo in CLOSED-LOOP) quindi lo rifiutiamo e la board non si muove. A quel punto si incasina tutto per sempre.

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160523_105446 0.6,0.25,0.2 T 120.365 398.676 20151212_233600 1.45682 T F
20160523_105513 0.6,0.25,0.2 T nan 631.678 20151212_233600 1.51714 T F

10:15 end of target

SDSS J1958+5950

10:20 Go on pointing star

10:36 Preset
Topic revision: r6 - 24 May 2016, LorenzoBusoni
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.