02:46UT: getting ready, spotters out.

SDSSJ1110+6459

03:00UT: telescope collimated.

03:09UT: loop closed, including spot optimization, at first try!

usual mask alignment

03:50UT: clouds on the target.

lo sapevo che era meglio il quaderno di bonaja. ho perso mezze note della notte perche non ho salvato...

telescope stopped quite a while for clouds. Then we tried SDSSJ134332.85+415503 without success. Then we finally closed for wind

Daytime on DX

Mainly SW test of the new mode that allows to close the loop in daytime automatically with every reconstructor.

The current SW version is OK and the operator is able to close the loop with the Arbitrator GUI with 2 caveats:
  1. After LGS Acquisition one must remember to copy the current hexapod position into the collimation table. See HowToEnableHexapodOffload
  2. The jitterGain must be set to 0.001 if ttst== None (and put back to nominal 0.4 otherwise)

Ci sono snapshots a LGSWonly, FLAO+LGSW (con TS bacato), FLAO only, FLAO+LGSW

LGSW only with jitterGain=0.001

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160522_135450 0.25,0.1,0.1 T 271.767 29.0457 20150704_021200 -1 T F LGSW nodist
20160522_135817 0.45,0.45,0.45 T 172.373 49.267 20150704_021200 -1 T F LGSW nodist
20160522_141333 0.45,0.45,0.45 T 201.58 58.3493 20150704_021200 -1 T F LGSW dist 08
20160522_141348 0.45,0.45,0.45 T 184.693 58.2975 20150704_021200 -1 T F LGSW dist 08
20160522_141759 0.45,0.45,0.45 T 277.604 78.3159 20150704_021200 -1 T F LGSW dist 12
20160522_141826 0.45,0.45,0.45 T 200.825 75.6029 20150704_021200 -1 T F LGSW dist 12

20160522_142400 Crash generale. Restart AOSL and ARGOS processes

Si prova con FLAO+LGSW

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160522_154140 0.8,0.45,0.4 T 215.634 92.028 20150704_021500 -1 T F FLAO+LGSW TS rotto
20160522_154245 0.8,0.45,0.4 T 190.542 72.7781 20150704_021500 -1 T F FLAO+LGSW TS rotto
20160522_154906 0.75,0.45,0.4 T 120.968 56.4335 20150704_021500 -1 T F FLAO+LGSW TS rotto
20160522_154927 0.75,0.45,0.4 T 129.637 53.4782 20150704_021500 -1 T F FLAO+LGSW TS rotto
20160522_155032 0.75,0.45,0.4 T 124.381 52.1657 20150704_021500 -1 T F FLAO+LGSW TS rotto
20160522_155156 0.75,0.45,0.4 T 107.961 48.2994 20150704_021500 -1 T F FLAO+LGSW TS rotto
20160522_155224 0.75,0.45,0.4 T 119.291 54.8739 20150704_021500 -1 T F FLAO+LGSW TS rotto

Questo set sotto mostra chiaramente problemi dovuti al Truth Sensing. I modi visti dalla piramide dapprima scendono e poi divergono. Il pupil centering del FLAO non sta funzionando e la pupilla e' spostata di svariate sottoaperture. Non capisco perche'. Aggiusto a mano la posizione della camera lens.

Provo FLAO only 36 modi. Il SW nuovo funziona

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160522_161647 0.35,0.05, 0 T 180.396 20.2529 20150704_021600 -1 T F FLAO
20160522_161821 0.65,0.5, 0 T 123.673 23.8427 20150704_021600 -1 T F FLAO
20160522_161835 0.65,0.5, 0 T 133.071 24.1657 20150704_021600 -1 T F FLAO
20160522_161903 0.65,0.5, 0 T 118.461 23.8345 20150704_021600 -1 T F FLAO
20160522_162433 2.05,1.3, 0 T 56.4829 26.171 20150704_021600 -1 T F FLAO dist 12
20160522_162451 2.05,1.3, 0 T 45.6875 25.9957 20150704_021600 -1 T F FLAO dist 12
20160522_162514 2.05,1.3, 0 T 47.1641 25.9966 20150704_021600 -1 T F FLAO dist 12
20160522_162534 2.05,1.3, 0 T 49.5921 25.4918 20150704_021600 -1 T F FLAO dist 12

Riprovo FLAO+LGSW con il TS funzionante.

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20160522_163119 1.6,0.45,0.45 T 57.4057 77.6386 20150704_021500 -1 T F FLAO+LGSW
20160522_163143 1.6,0.45,0.45 T 64.2591 77.8666 20150704_021500 -1 T F FLAO+LGSW
20160522_163155 1.6,0.45,0.45 T 55.0148 74.2794 20150704_021500 -1 T F FLAO+LGSW