19:30: telescope open, flats taken, we notice a strange pattern on LUCI1 detector, probably it is due to consensation on LUCI entrance window.
NGC2419
20:20: preset sent as mag 14. Problems with timeout when preset is sent through LUCI. We are also facing into the wind, shells are failing.
Hip49046
20:50: still having problems with presets, timeout occurring...
lgsw.tools.patrol_lgs_jitter
: procedure to acquire fast frames from patrol cameras.
LBFC: it seems that no astigmatism is present, corrector at 76 steps, focus at -80k steps:
TN |
AO Gain |
Res. WF [nm rms] |
AO rec |
DIMM ["] |
JCL |
PCL |
Notes |
20160313_044236 |
0, 0, 0 |
NA |
NA |
1.43133 |
F |
F |
LBFC opt |
20160313_044254 |
0, 0, 0 |
NA |
NA |
1.56875 |
F |
F |
LBFC opt |
20160313_044310 |
0, 0, 0 |
NA |
NA |
1.61722 |
F |
F |
LBFC opt |
20160313_044328 |
0, 0, 0 |
NA |
NA |
1.68334 |
F |
F |
LBFC opt |
20160313_044345 |
0, 0, 0 |
NA |
NA |
1.74727 |
F |
F |
LBFC opt |
20160313_044402 |
0, 0, 0 |
NA |
NA |
1.8105 |
F |
F |
LBFC opt |
Then we acquire the IM between jitter and LAS pupil mirror.
New pupil positions on-sky:
Pupil |
X |
Y |
Red |
525 |
410 |
Yellow |
360 |
440 |
Blue |
340 |
420 |
PBL also with
BCU: it fades when closing loop (we're using PYR as TT sensor).
23:30:
PBL wiht PCD: it is shutdown and it does not restart!
00:00: AOS timeout fixed (see Josè and Steve's e-mails of 13/03/2016: "Changes made to aos.conf")
NGC4449
00:20: preset as mag 14.6, mag 15.7 on PYR (FW1= 600-1000)
SX and DX PCD are swapped
NGC5921
3:20: preset as mag 16.5, mag 17 on PYR (FW1= 600-1000)
We could close the AO loop for at least 1min...
LBFC: corrector @ 530 steps, focus @ -150k.
5:20:
BCU voltage trimmed to 3.485V
TN |
AO Gain |
Res. WF [nm rms] |
AO rec |
DIMM ["] |
JCL |
PCL |
Notes |
20160313_113257 |
1.5,0.25,0.1 |
255.214 |
20151212_233600 |
0.867335 |
T |
F |
|
20160313_113320 |
1.5,0.25,0.1 |
251.279 |
20151212_233600 |
0.90884 |
T |
F |
|
20160313_114243 |
0.2,0.1, 0 |
1300.81 |
20151212_233600 |
0.976432 |
T |
F |
|
20160313_114302 |
0.2,0.1, 0 |
1326.88 |
20151212_233600 |
0.909394 |
T |
F |
|
20160313_114319 |
0.2,0.1, 0 |
488.533 |
20151212_233600 |
0.965491 |
T |
F |
|
20160313_114402 |
0.2,0.1, 0 |
457.264 |
20151212_233600 |
1.07509 |
T |
F |
|
20160313_114418 |
0.2,0.1, 0 |
514.632 |
20151212_233600 |
1.09358 |
T |
F |
|
20160313_114434 |
0.2,0.1, 0 |
444.984 |
20151212_233600 |
1.085 |
T |
F |
|
20160313_114511 |
0.2,0.1, 0 |
607.089 |
20151212_233600 |
1.04035 |
T |
F |
|
20160313_114526 |
0.2,0.1, 0 |
528.837 |
20151212_233600 |
0.996058 |
T |
F |
|
20160313_114545 |
0.2,0.1, 0 |
396.179 |
20151212_233600 |
1.04953 |
T |
F |
|
20160313_114617 |
0.2,0.1, 0 |
486.944 |
20151212_233600 |
0.971762 |
T |
F |
|
20160313_120034 |
1.5,0.4,0.3 |
265.277 |
20151212_233600 |
-1 |
T |
F |
|
LBFC:
TN |
AO Gain |
Res. WF [nm rms] |
AO rec |
DIMM ["] |
JCL |
PCL |
Notes |
20160313_123034 |
1.5, 0, 0 |
348.983 |
20151212_233600 |
-1 |
F |
F |
LBFC opt |
20160313_123053 |
1.5, 0, 0 |
352.997 |
20151212_233600 |
-1 |
F |
F |
LBFC opt |
20160313_123110 |
1.5, 0, 0 |
345.053 |
20151212_233600 |
-1 |
F |
F |
LBFC opt |
20160313_123129 |
1.5, 0, 0 |
341.813 |
20151212_233600 |
-1 |
F |
F |
LBFC opt |
20160313_123148 |
1.5, 0, 0 |
344.79 |
20151212_233600 |
-1 |
F |
F |
LBFC opt |
20160313_123206 |
1.5, 0, 0 |
342.503 |
20151212_233600 |
-1 |
F |
F |
LBFC opt |
--
MarcoBonaglia - 22 Mar 2016