21:00: spotters are out

[BDS2003]65

the available guide star is too faint. We change target

Hip1813

22:20: AArb configured for magnitude 16.

23:30: FLAO slopes fail -> we switch to QC

PBL with rotator direction, it seems we must change the derotation to counter-clockwise...

QC set at 50Hz, and then also 20Hz. We have magnitude 17 on PYR.

NGC2490

J band images. Almost 1.8" seeing, we get 0.6" FWHM in closed loop...

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151217_073802 1.5,0.45,0.35 140.05 20151213_063700 -1 T F Auto
20151217_073913 1.5,0.45,0.35 144.321 20151213_063700 -1 T F Auto
20151217_074023 1.5,0.45,0.35 260.867 20151213_063700 -1 T F Auto
20151217_074132 1.5,0.3,0.15 738.441 20151213_063700 -1 T F Auto
20151217_074240 1.5,0.3,0.15 445.887 20151213_063700 -1 T F Auto
20151217_074348 0.1, 0, 0 672.997 20151213_063700 -1 T F Auto
20151217_074458 1.15,0.4,0.3 215.015 20151213_063700 1.62076 T F Auto
20151217_074608 1.15,0.4,0.3 223.563 20151213_063700 1.91127 T F Auto
20151217_074718 1.15,0.4,0.3 632.991 20151213_063700 1.76964 T F Auto
20151217_074926 0.1, 0, 0 518.594 20151213_063700 1.66678 T F Auto
20151217_075036 0.2,0.1,0.05 214.85 20151213_063700 1.50948 T F Auto
20151217_075146 1.15,0.4,0.3 147.589 20151213_063700 1.56696 T F Auto
20151217_075255 1.15,0.4,0.3 183.622 20151213_063700 1.5277 T F Auto
20151217_075404 1.15,0.4,0.3 230.109 20151213_063700 1.58423 T F Auto
20151217_075514 1.15, 0, 0 687.286 20151213_063700 2.12747 T F Auto
20151217_075623 1.15,0.4,0.3 138.3 20151213_063700 1.89453 T F Auto
20151217_075733 1.15,0.4,0.3 342.184 20151213_063700 1.88364 T F Auto
20151217_075843 1.15,0.4,0.3 197.903 20151213_063700 2.17688 T F Auto
20151217_075952 1.15,0.4,0.3 125.108 20151213_063700 1.6213 T F Auto
20151217_080101 1.15,0.4,0.3 173.982 20151213_063700 1.45618 T F Auto
20151217_080211 1.15,0.4,0.3 138.64 20151213_063700 1.64963 T F Auto
20151217_080521 1.15,0.4,0.3 402.214 20151213_063700 -1 T F Auto
20151217_080629 1.15,0.4,0.3 762.632 20151213_063700 -1 T F Auto
20151217_080737 1.15,0.4,0.3 609.321 20151213_063700 -1 T F Auto
20151217_080845 1.15,0.4,0.3 722.022 20151213_063700 1.64989 F F Auto
20151217_080953 1.15,0.4,0.3 545.392 20151213_063700 1.51467 T F Auto
20151217_081101 0.1, 0, 0 648.813 20151213_063700 -1 T F Auto
20151217_081210 0.2,0.1, 0 201.195 20151213_063700 -1 T F Auto
20151217_081319 1.15,0.4,0.3 156.881 20151213_063700 1.26621 T F Auto
20151217_081429 1.15,0.4,0.3 155.786 20151213_063700 1.54699 T F Auto
20151217_081538 1.15,0.4,0.3 180.241 20151213_063700 1.57981 T F Auto
20151217_081648 1.15,0.4,0.3 160.389 20151213_063700 1.43785 T F Auto
20151217_081757 0,0.4,0.3 256.07 20151213_063700 1.63737 T F Auto
20151217_081907 1.15,0.4,0.3 164.249 20151213_063700 1.63491 T F Auto
20151217_082017 0.1, 0, 0 551.789 20151213_063700 1.72958 T F Auto
20151217_082127 0.1, 0, 0 1220.09 20151213_063700 1.95456 T F Auto
20151217_082235 0.1, 0, 0 426.197 20151213_063700 -1 T F Auto
20151217_082343 0.1, 0, 0 546.124 20151213_063700 -1 T F Auto
20151217_082552 0.1, 0, 0 583.26 20151213_063700 -1 T F Auto
20151217_082700 0.1, 0, 0 781.87 20151213_063700 -1 F F Auto
20151217_082808 0.1, 0, 0 608.262 20151213_063700 -1 T F Auto
20151217_082915 0.1, 0, 0 562.419 20151213_063700 -1 T F Auto
20151217_083023 0.2,0.1,0.05 643.692 20151213_063700 -1 F F Auto
20151217_083131 1.15,0.4,0.3 591.108 20151213_063700 -1 F F Auto
20151217_083239 0.1, 0, 0 443.832 20151213_063700 -1 T F Auto
20151217_083346 1.15,0.4,0.3 182.998 20151213_063700 -1 T F Auto
20151217_083455 1.15,0.4,0.3 184.047 20151213_063700 -1 T F Auto
20151217_083605 1.15,0.4,0.3 192.708 20151213_063700 -1 T F Auto
20151217_083714 1.15,0.4,0.3 150.297 20151213_063700 -1 T F Auto
20151217_083824 1.15,0.4,0.3 140.752 20151213_063700 -1 T F Auto
20151217_084040 0,0.4,0.3 544.917 20151213_063700 -1 F F Auto
20151217_084648 0, 0, 0 610.075 20151213_063700 -1 F F Auto
20151217_084756 0, 0, 0 1275.96 20151213_063700 -1 T F Auto
20151217_084903 0.1, 0, 0 765.705 20151213_063700 -1 T F Auto
20151217_085011 0.2,0.1,0.05 NA NA NA T F Auto
20151217_085127 0.1, 0, 0 733.142 20151213_063700 -1 T F Auto
20151217_085236 0.115,0.4,0.3 492.619 20151213_063700 -1 T F Auto
20151217_085345 0.2,0.1, 0 642.18 20151213_063700 1.31144 F F Auto
20151217_085453 0.2,0.1, 0 562.894 20151213_063700 -1 F F Auto
20151217_085600 0.2,0.1, 0 628.29 20151213_063700 -1 T F Auto
20151217_085708 0.2,0.1, 0 817.41 20151213_063700 -1 T F Auto
20151217_085816 0.2,0.1, 0 513.54 20151213_063700 -1 F F Auto
20151217_085923 0.2,0.1, 0 690.64 20151213_063700 -1 T F Auto
20151217_090031 0.2,0.1, 0 592.202 20151213_063700 -1 T F Auto

NGC4102

2:20: we move to this target. We close at 3:50. Preset sent for mag=14 on QC. We are guiding on the galaxy core. FW1: 90/10. Mag=17 on PYR.

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151217_104951 3,0.4,0.3 270.882 20151213_063700 -1 T F Auto
20151217_105102 3,0.4,0.3 243.089 20151213_063700 2.14785 T F Auto
20151217_105212 3,0.4,0.3 191.759 20151213_063700 1.87872 T F Auto
20151217_105322 3,0.4,0.3 199.944 20151213_063700 2.00509 T F Auto
20151217_105432 7,0.4,0.3 254.094 20151213_063700 1.74461 T F Auto
20151217_105542 5,0.25,0.1 570.477 20151213_063700 1.99858 F F Auto
20151217_105650 5,0.25,0.1 605.915 20151213_063700 1.82586 F F Auto
Then we try with double star:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151217_111845 1.5,0.4,0.3 198.238 20151213_063700 1.40486 T F Auto
20151217_111955 0, 0, 0 531.466 20151213_063700 1.39373 T F Auto
20151217_112105 0.1, 0, 0 573.819 20151213_063700 1.42497 T F Auto
20151217_112215 0.5,0.4,0.05 166.889 20151213_063700 1.34206 T F Auto
20151217_112324 0.5,0.4,0.3 358.517 20151213_063700 1.28236 T F Auto
5:00: software crash... we must restart... we point back to Hip star

Hip49628

Then we optimize the beam shape:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151217_124127 0.1, 0, 0 360.097 20151213_063700 -1 F F LBFC opt
20151217_124143 0.1, 0, 0 351.202 20151213_063700 -1 F F LBFC opt
20151217_124159 0.1, 0, 0 357.923 20151213_063700 -1 F F LBFC opt
20151217_124215 0.1, 0, 0 356.593 20151213_063700 2.1739 F F LBFC opt
20151217_124230 0.1, 0, 0 359.132 20151213_063700 -1 F F LBFC opt
20151217_124246 0.1, 0, 0 362.792 20151213_063700 -1 F F LBFC opt
20151217_124302 0.1, 0, 0 358.407 20151213_063700 -1 F F LBFC opt
20151217_124318 0.1, 0, 0 352.365 20151213_063700 1.66563 F F LBFC opt
20151217_124334 0.1, 0, 0 358.165 20151213_063700 1.68237 F F LBFC opt

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151217_131430 2,0.4,0.3 229.218 20151213_063700 1.52024 T F Auto
20151217_131540 2,0.4,0.3 187.442 20151213_063700 2.44475 T F Auto
20151217_131650 2,0.04,0.03 435.709 20151213_063700 2.00719 T F Auto
20151217_131759 0.2,0.1,0.05 202.33 20151213_063700 1.49183 T F Auto
20151217_131909 0, 0, 0 534.361 20151213_063700 1.5977 T F Auto
20151217_132017 0, 0, 0 609.776 20151213_063700 1.73498 T F Auto
20151217_132125 0, 0, 0 566.007 20151213_063700 1.84281 F F Auto
20151217_133131 0, 0, 0 335.949 20151213_063700 1.45206 F F
20151217_133204 0, 0, 0 339.084 20151213_063700 1.57348 F F
20151217_133334 0, 0, 0 356.777 20151213_063700 1.65249 T F Auto
20151217_133442 0, 0, 0 426.837 20151213_063700 1.47149 T F Auto
20151217_133550 0, 0, 0 606.761 20151213_063700 1.83223 T F Auto

LAT test

6:20: we perform calibrations of LAT flexures

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151217_135100 0, 0, 0 217.071 20151213_063700 -1 F F Auto
20151217_135207 0, 0, 0 36.968 20151213_063700 -1 F F Auto
20151217_135314 0, 0, 0 36.8591 20151213_063700 -1 F F Auto
20151217_135422 0, 0, 0 36.609 20151213_063700 -1 F F Auto
20151217_135528 0, 0, 0 36.8482 20151213_063700 -1 F F Auto
20151217_135635 0, 0, 0 37.3952 20151213_063700 -1 F F Auto
20151217_135743 0, 0, 0 36.5744 20151213_063700 -1 F F Auto
20151217_135850 0, 0, 0 36.8001 20151213_063700 -1 F F Auto
20151217_135957 0, 0, 0 36.4454 20151213_063700 -1 F F Auto
20151217_140104 0, 0, 0 37.5306 20151213_063700 -1 F F Auto
20151217_140212 0, 0, 0 37.3258 20151213_063700 -1 F F Auto
20151217_140319 0, 0, 0 37.5724 20151213_063700 -1 F F Auto
20151217_140426 0, 0, 0 37.3562 20151213_063700 -1 F F Auto
20151217_140533 0, 0, 0 36.9556 20151213_063700 -1 F F Auto
20151217_140641 0, 0, 0 37.3674 20151213_063700 -1 F F Auto
20151217_140749 0, 0, 0 36.7454 20151213_063700 -1 F F Auto
20151217_140856 0, 0, 0 37.7074 20151213_063700 -1 F F Auto
20151217_141003 0, 0, 0 37.0463 20151213_063700 -1 F F Auto
20151217_141110 0, 0, 0 37.0702 20151213_063700 -1 F F Auto
20151217_141220 0, 0, 0 36.2023 20151213_063700 -1 F F Auto
20151217_141326 0, 0, 0 35.8504 20151213_063700 -1 F F Auto
20151217_141434 0, 0, 0 35.7774 20151213_063700 -1 F F Auto
20151217_141541 0, 0, 0 36.0781 20151213_063700 -1 F F Auto
20151217_141649 0, 0, 0 36.2655 20151213_063700 -1 F F Auto
-- MarcoBonaglia - 11 Jan 2016