Dome open all night...

OL images on LUCI1, OH band are about 13px FWHM, very bad seeing!

Beam shaping test

We exercise the beam shaping procedure

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Plot
20151216_021849 0, 0, 0 NA NA 1.52231 F F LBFC opt  
20151216_021907 0, 0, 0 NA NA 1.95699 F F LBFC opt  
20151216_021925 0, 0, 0 NA NA 2.12942 F F LBFC opt  
20151216_021943 0, 0, 0 NA NA 2.82732 F F LBFC opt  
20151216_022001 0, 0, 0 NA NA 1.17797 F F LBFC opt  
20151216_022019 0, 0, 0 NA NA 0.961211 F F LBFC opt  
20151216_022037 0, 0, 0 NA NA 2.24568 F F LBFC opt  
20151216_022055 0, 0, 0 NA NA 0.701472 F F LBFC opt  
20151216_022114 0, 0, 0 NA NA 1.23133 F F LBFC opt  
20151216_022132 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022230 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022247 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022305 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022323 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022342 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022400 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022419 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022436 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022455 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_022513 0, 0, 0 NA NA -1 F F LBFC opt  
20151216_031358 0, 0, 0 361.127 20151212_233400 2.0859 F F LBFC opt 20151216_031358_LBFCopt.jpg
20151216_031417 0, 0, 0 357.723 20151212_233400 2.1015 F F LBFC opt
20151216_031437 0, 0, 0 363.916 20151212_233400 2.18395 F F LBFC opt
20151216_031456 0, 0, 0 358.036 20151212_233400 2.20833 F F LBFC opt
20151216_031517 0, 0, 0 354.458 20151212_233400 2.18916 F F LBFC opt
20151216_031536 0, 0, 0 354.688 20151212_233400 2.15607 F F LBFC opt
20151216_031556 0, 0, 0 360.754 20151212_233400 2.09911 F F LBFC opt
20151216_031616 0, 0, 0 363.986 20151212_233400 2.11498 F F LBFC opt
20151216_031635 0, 0, 0 363.049 20151212_233400 2.14791 F F LBFC opt
20151216_031655 0, 0, 0 359.88 20151212_233400 2.1666 F F LBFC opt
20151216_031843 0, 0, 0 657.461 20151212_233400 2.119 F F LBFC opt 20151216_031843_LBFCopt.jpg
20151216_031904 0, 0, 0 691.473 20151212_233400 1.99878 F F LBFC opt
20151216_031924 0, 0, 0 507.805 20151212_233400 1.91678 F F LBFC opt
20151216_031943 0, 0, 0 414.272 20151212_233400 1.9694 F F LBFC opt
20151216_032003 0, 0, 0 385.247 20151212_233400 1.92436 F F LBFC opt
20151216_032023 0, 0, 0 369.407 20151212_233400 2.19325 F F LBFC opt
20151216_032043 0, 0, 0 359.303 20151212_233400 2.18359 F F LBFC opt
20151216_032103 0, 0, 0 363.516 20151212_233400 2.16434 F F LBFC opt
20151216_032123 0, 0, 0 366.779 20151212_233400 2.1517 F F LBFC opt
20151216_032143 0, 0, 0 366.043 20151212_233400 2.19044 F F LBFC opt
21:00: M1 panic! An electrovalve of the pneumatic system must be exchanged.

We verify that the best cube rotator position on SX AGW to not vignette LUCI1 is 90deg.

00:50: back to sky, 1:10 we are acquired again. We close the NGS TT loop.

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151216_081044 1.5, 0, 0 400.239 20151212_233400 1.06444 F F LBFC opt 20151216_081044_LBFCopt.jpg
20151216_081102 1.5, 0, 0 394.615 20151212_233400 1.08449 F F LBFC opt
20151216_081120 1.5, 0, 0 396.735 20151212_233400 1.07149 F F LBFC opt
20151216_081138 1.5, 0, 0 385.731 20151212_233400 1.05931 F F LBFC opt
20151216_081156 1.5, 0, 0 385.17 20151212_233400 1.09567 F F LBFC opt
20151216_081215 1.5, 0, 0 389.459 20151212_233400 1.12467 F F LBFC opt
20151216_081233 1.5, 0, 0 392.483 20151212_233400 1.13762 F F LBFC opt
20151216_081250 1.5, 0, 0 394.553 20151212_233400 1.17245 F F LBFC opt
20151216_081308 1.5, 0, 0 392.579 20151212_233400 1.17701 F F LBFC opt
20151216_081326 1.5, 0, 0 388.193 20151212_233400 1.16859 F F LBFC opt
20151216_082009 1.5, 0, 0 380.325 20151212_233400 1.21258 F F LBFC opt 20151216_082009_LBFCopt.jpg
20151216_082027 1.5, 0, 0 380.53 20151212_233400 1.18457 F F LBFC opt
20151216_082045 1.5, 0, 0 387.046 20151212_233400 1.18391 F F LBFC opt
20151216_082103 1.5, 0, 0 379.816 20151212_233400 1.21535 F F LBFC opt
20151216_082121 1.5, 0, 0 370.774 20151212_233400 1.21161 F F LBFC opt
20151216_082140 1.5, 0, 0 380.447 20151212_233400 1.21117 F F LBFC opt
20151216_082158 1.5, 0, 0 385.307 20151212_233400 1.18498 F F LBFC opt
20151216_082215 1.5, 0, 0 387.957 20151212_233400 1.17131 F F LBFC opt
20151216_082234 1.5, 0, 0 384.002 20151212_233400 1.15965 F F LBFC opt
20151216_082252 1.5, 0, 0 386.672 20151212_233400 1.16584 F F LBFC opt
Then we move to CL operations:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151216_092412 1, 0, 0 254.54 20151212_233400 -1 T F CL on 10 modes 20151216_092412-20151216_092937_modalplot.png
20151216_092435 1, 0, 0 290.69 20151212_233400 -1 T F
20151216_092615 1, 0, 0 215.376 20151212_233400 -1 T F 150 modes
20151216_092634 1, 0, 0 209.101 20151212_233400 -1 T F
20151216_092711 1, 0, 0 253.749 20151212_233400 -1 T F
20151216_092732 1, 0, 0 241.956 20151212_233400 -1 T F
20151216_092937 1, 0, 0 391.806 20151212_233400 -1 T F

Hip 49628

We close the loop from AArb, we test dithering (OL on NGS) and big offsets (OL on everything)

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20151216_101244 1.2,0.3,0.15 148.748 20151212_233400 1.39972 T F Auto
20151216_101357 1.2,0.4,0.35 121.938 20151212_233400 1.40405 T F Auto
20151216_101509 1.2,0.45,0.4 114.691 20151212_233400 1.38904 T F Auto
20151216_101621 1.2,0.45,0.4 107.85 20151212_233400 1.35726 T F Auto
20151216_101734 1.2, 0, 0 354.352 20151212_233400 1.27995 T F Auto - No light on LGSW
20151216_101847 1.2,0.45,0.4 113.511 20151212_233400 1.20869 T F Auto
20151216_102118 1.2,0.45,0.4 115.484 20151212_233400 1.14092 T F
20151216_102205 1.2,0.45,0.4 112.369 20151212_233400 1.18207 T F
20151216_102245 1.2,0.45,0.4 105.484 20151212_233400 1.18333 T F
20151216_102342 1.2,0.45,0.4 114.059 20151212_233400 1.32153 T F Auto
20151216_102454 1.2,0.45,0.4 107.034 20151212_233400 1.28839 T F Auto
20151216_102608 1.2,0.45,0.4 367.215 20151212_233400 1.22522 T F Auto
20151216_102721 1.2,0.45,0.4 538.578 20151212_233400 1.09067 T F Auto
20151216_102833 1.2,0.45,0.4 596.459 20151212_233400 1.13994 T F Auto
20151216_102945 1.2,0.45,0.4 542.912 20151212_233400 1.27346 T F Auto
20151216_103057 1.2,0.45,0.4 553.066 20151212_233400 1.32019 T F Auto
20151216_103210 1.2,0.45,0.4 425.789 20151212_233400 1.34218 T F Auto
20151216_103323 0.1, 0, 0 285.598 20151212_233400 1.27723 T F Auto
20151216_103437 1.2,0.45,0.4 189.82 20151212_233400 1.26384 T F Auto
20151216_103550 0.2,0.1,0.05 603.702 20151212_233400 1.32347 T F Auto
20151216_103703 1,0.3,0.15 173.311 20151212_233400 1.39279 T F Auto
20151216_103916 0.2,0.1,0.05 126.814 20151212_233400 1.46056 T F Auto
20151216_104029 1,0.3,0.15 128.66 20151212_233400 1.49156 T F Auto
20151216_104141 1,0.3,0.15 503.906 20151212_233400 1.50033 T F Auto
20151216_104254 1,0.3,0.15 477.589 20151212_233400 -1 T F Auto
20151216_104406 1,0.3,0.15 556.729 20151212_233400 -1 F F Auto
20151216_104518 0.2,0.1,0.05 131.311 20151212_233400 -1 T F Auto
20151216_104630 1.15,0.45,0.4 126.766 20151212_233400 -1 T F Auto
20151216_104743 1.15,0.45,0.4 147.81 20151212_233400 -1 T F Auto
20151216_104855 1.15,0.4,0.3 113.205 20151212_233400 -1 T F Auto
20151216_105008 1.15,0.4,0.3 113.704 20151212_233400 -1 T F Auto
20151216_105122 1.15,0.4,0.3 139.568 20151212_233400 -1 T F Auto
20151216_105312 1.15,0.4,0.3 125.376 20151212_233400 1.40984 T F Auto
20151216_105426 1.15,0.4,0.3 155.035 20151212_233400 1.39772 T F Auto
20151216_105538 0,0.4,0.3 794.85 20151212_233400 1.45818 T F Auto
20151216_105651 0,0.4,0.3 719.389 20151212_233400 1.42002 F F Auto
We point again, same target:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151216_110612 0,0.4,0.3 NA NA NA T F Auto  
20151216_110733 0,0.4,0.3 356.405 20151212_233400 1.56025 T F Auto 20151216_110733-20151216_114818_modalplot.png
20151216_110846 0.2,0.1, 0 466.981 20151212_233400 1.41163 F F Auto
20151216_111059 0.2, 0, 0 559.772 20151212_233400 1.54952 F F Auto
20151216_114239 1,0.45,0.3 129.454 20151212_233400 -1 T F
20151216_114438 1,0.45,0.3 117.943 20151212_233400 -1 T F Auto
20151216_114551 1,0.45,0.3 116.743 20151212_233400 -1 T F Auto
20151216_114705 1,0.45,0.3 1105.6 20151212_233400 -1 T F Auto
20151216_114818 0.2,0.1,0.05 157.973 20151212_233400 -1 T F Auto
20151216_114930 1,0.15,0.05 116.686 20151212_233400 -1 T F Auto 20151216_114930-20151216_115800_modalplot.png
20151216_115043 1,0.15,0.05 111.589 20151212_233400 -1 T F Auto
20151216_115156 1,0.15,0.05 133.155 20151212_233400 -1 T F Auto
20151216_115308 1,0.15,0.05 145.328 20151212_233400 -1 T F Auto
20151216_115421 1,0.15,0.05 146.266 20151212_233400 -1 T F Auto
20151216_115535 1,0.15,0.05 167.952 20151212_233400 -1 T F Auto
20151216_115647 1,0.15,0.05 435.244 20151212_233400 -1 T F Auto
20151216_115800 1,0.15,0.05 598.168 20151212_233400 -1 T F Auto
20151216_115914 1,0.15,0.05 NA NA NA T F Auto  
20151216_120236 1,0.15,0.05 575.326 20151212_233400 -1 F F Auto 20151216_120236-20151216_120725_modalplot.png
20151216_120348 1,0.15,0.05 588.19 20151212_233400 -1 F F Auto
20151216_120459 1,0.15,0.05 431.182 20151212_233400 -1 T F Auto
20151216_120612 1,0.15,0.05 411.025 20151212_233400 -1 T F Auto
20151216_120725 1,0.15,0.05 549.057 20151212_233400 -1 T F Auto
Then we move to BIN4:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151216_122253 1,0.4,0.35 117.06 20151212_233600 -1 T F Auto 20151216_122253-20151216_122519_modalplot.png
20151216_122406 1,0.4,0.35 120.026 20151212_233600 -1 T F Auto
20151216_122519 0, 0, 0 NA NA -1 T F Auto

SDSSJ1110+6459

Last pointing @45deg:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151216_125433 0, 0, 0 NA NA 1.34918 T F Auto 20151216_125433-20151216_130136_modalplot.png
20151216_125545 0.2,0.1,0.05 128.759 20151212_233600 1.16514 T F Auto
20151216_125659 1,0.4,0.25 165.77 20151212_233600 1.22926 T F Auto
20151216_125811 0, 0, 0 435.148 20151212_233600 1.08266 T F Auto
20151216_125922 1,0.3,0.1 161.96 20151212_233600 1.03776 T F Auto
20151216_130136 1,0.35,0.1 135.002 20151212_233600 1.33177 T F Auto
-- MarcoBonaglia - 11 Jan 2016