Children of ListOfHowTo in ARGOS Web

Results from ARGOS web retrieved at 10:41 (GMT)

ChangingModalBasis
Changing between existing Calibrated Modal Basis DX can operate with either the KL_v22 or KL_v26 modal basis, althought he KL_v26 is the preferred. To switch the ...
HowToAddANewModalBasis
How to Add a New Modal Basis When the ASM is re calibrated a new modal basis is created and saved in the ASM computer.We need to produce a local copy of the modal...
HowToAddCalUnitSwingArmInfoToSnapshot
The ARGOS calibration unit swing arm position is not available into the snapshot, but it is used to distinguish between daytime and on sky data. This information ...
HowToAuthorizeLUCIAtARGOS
How to authorize LUCI@ARGOS focal station 0) login as LBTO on obs x , see UsefulLoginInfo 1) from terminal start TCSGUI 2) click on IIF GUI button 3) on Instrumen...
HowToBuildFlaoAndTrueSensRecsForArgos
How to Build FLAO and TrueSens Recs for ARGOS If there are new FLAO Recs this procedure will guide you in building the Rec for ARGOS based on the new FLAO Recs.FL...
HowToCalibrateLgsAcquisition
The ARGOS acquisition sequence make use of 4 different algorithms: 1 LAN LM1 to LAT: used at the beginning of the night to bring the lasers within the 1' FoV o...
HowToCalibrateLgsGuiding
ARGOS implements the LGS guiding with many different algorithms: 1 LAS pupil mirror to quad cell: a quadcell like algorithm is used on the patrol camera images...
HowToChageFLAOPupilMask
How to Change FLAO Pupil Mask To change the pupil mask, at a flao sxwfs or flao dxwfs terminal type: i. change_binning.py 1 It will print a numbered list of pu...
HowToCheckVibrationCompensationAccelerometers
Bad connected accelerometers can lead to faulty behaviour of the vibration compensation system. This method can be used to check for problems with the acceleromet...
HowToConvertDisturbanceInNewModalBasis
How to Convert Disturbance in New Modal Basis The Adsec Disturbances are Adsec Commands Matrices. To convert the Disturbances in a new modal basis the first step ...
HowToCreateACalibratedModalAmplitudeForModalHistory
How to Create a Calibrated Modal Amplitude for Modal History This guide helps you to create a calibrated modal amplitude for modal history push pull.Normally one ...
HowToCreateACombinedReconstructor
!!!! Keep track of your work !!!! !!!! Remember to keep track of the recorded IMs and all RECs built into the following pages: * DXAoLoopCalibrations * SXAo...
HowToCreateASingleLgswReconstructor
!!!! Keep track of your work !!!! !!!! Remember to keep track of the recorded IMs and all RECs built into the following pages: * DXAoLoopCalibrations * SXAo...
HowToCreateLBTCatalogFiles
How to create an LBT star catalog file If you want to point and guide on a star it is mandatory to have a catalog file installed in the LBT TCS. Catalog file form...
HowToDefineLgswSubapertures
How to define a subapertures set To create a new subapertures set or just modify the slope computing method you have 2 possibilities: 1 create a new subapertur...
HowToDoAPerformanceCheckOnNewRec
How to Do a Performance Check on New Rec Testing the interaction matrix The first test on interaction matrix is based on a visual check of the matrix with the co...
HowToExchangeLaserHeads
Main.SebastianRabien 15 Dec 2015 When to exchange a laser head? A laser heads needs to be exchanged if it is broken. This is the case if a laser shows very low p...
HowToGenerateSinusoidalDisturbance
How to generate sinusoidal disturbances from argos.arbitrator.aoloop.sinusoidal_disturbance import SinusoidalDisturbance sinDist= SinusoidalDisturbance(argos.aar...
NEW - 22 Feb 2018 - 20:11 by TommasoMazzoni
HowToGetDIMMMeasurements
We describe two ways to get DIMM, or by extension any LBT telemetry, data: * with on the fly plot GUI called LBTplot * by retrieving text files. More inform...
r2 - 03 Feb 2016 - 16:17 by GillesOrban
HowToGetInformationAboutOldCalibration
How to Get Information about Old Calibration The starting point is the tag of a combined reconstructor. All the information about the reconstructor is inside the ...
HowToInstallARGOSFiberSplitter
* * IMPORTANT: This configuration has been removed. Final solution uses a fiber switch. It is left here for reference only. (GR/2017 02 10) See HowToUseTheFiberSw...
HowToInstallNewReconstructorInArgosSW
How to Install New Reconstructor in ARGOS SW After a calibration you have to update the argos configuration table. In "argos_trunk/site/lbt/common/insroot/etc/arg...
HowToLimitTheJitterCompensationLoopStroke
If the spots are very broad you could try to limit the jitter loop stroke to avoid them to jump on the next subaperture. Anyhow before you probably would try to o...
HowToMeasureLgswFovPosition
This procedure is used to match the 3 LGS images produced by the CalUnitSystem to the LgswUnit entrance FoVs. It is composed by a measurement procedure that scans...
HowToOptimizeSpotOnPatrolCameras
How to Optimize Spot on Patrol Cameras This topic contains the instructions to optimize the spot on the Patrol Cameras moving the Launch Beam Corrector and the Fo...
HowToPerformArgosAoLoopInDayTime
How to perform ARGOS closed loop in daytime This HowTo explains how to close an AO loop with the ARGOS system in daytime using the CalUnit as reference source. Th...
HowToPerformArgosCalibrations
How to perform ARGOS LGSW to ADSEC calibrations This HowTo describes what to do to create a new reconstructor for the AO loop. The description tries to include al...
HowToPowerCycleTheRemotePowerSwitch
Use circuit breaker F22 on the remote power front panel (most right, upper row. labeled "REMOTE POWER"). Location: Lower argos plattform, SX rack, upper half. M...
HowToRecoverStuckLgswPupilMotor
A session on this topic has already been created in the Device List pages of the NSA12 stepper motors: * Symptom * Possible cause * Procedure to recover ...
HowToRestartAdSec
The documentation about how to start/stop, restart, and properly power off the LBT AdSec is maintained in the LBTO Twiki at the current page: http://wiki.lbto.org...
HowToRetrieveLGSOrientationInLUCIImages
Orientation on the DX side See email to Gilles and Lorenzo of 28/02/2015: So from our evaluation the LUCI CCD top is vertical in the telescope system when the rot...
HowToRunSiteSxSim
1 Install site sx sim, e.g.: cd argos_trunk/site/sx sim make install 1 Follow instructions in README. Anonymous access with username anon and password...
HowToSetupARGOSForCalibrations
How To Setup ARGOS for AO calibrations Pre requisits: * Coordinate telescope access with Telescope Manager and mail to telescopework * Telescope must be ...
HowToSetupHexapodForCalibrationUnit
This topic contains the history of best hexapod position to align the CalUnitSystem to LUCI and LGSW * X, Y, Z, Rx, Ry, Rz are the hexapod absolute position ...
HowToStartIRTC
Start up The HW is typically always on. In case you need to access it, the control PC is in the lower treehouse. i. Login as LBTO on obs x . See UsefulLoginInf...
HowToStartMirrorGUI
How to start Mirror GUI i. login into adsecdx (or adsecsx), see UsefulLoginInfo i. from terminal open adsceng i. click on AdSec Control GUI and AdSec Mir...
HowToStartPyramidWfs
How to start FLAO Pyramid WFS i. Login as "AOeng" into soul dxwfs (or soul sxwfs) and check if the WFS processes are running with w_check.If that is the case, ...
HowToStartTipTiltSystem
i. Login into LGSW machine: see UsefulLoginInfo i. Start the TipTiltSystem controller GUI: argos_sx_tiptilt_controller_gui i. Start the TipTiltSystem Apertu...
HowToStopUpsServiceOnCentos
sudo upsmon c stop Main.TommasoMazzoni 16 Mar 2015
NEW - 16 Mar 2015 - 09:29 by TommasoMazzoni
HowToTestLGSWEntranceWindowTransmissivity
How to test LGSW entrance window transmissivity Measure LGSW entrance window in transmission 1. Setup the LGSW for daytime activity: deploy calibration source...
HowToTuneLasersSHG
Main.SebastianRabien 15 Dec 2015 From time to time the Innolas lasers require a tuning of the SHG temperature to maintain the power level. This should be done whe...
HowToUpdateTheArgosInstrumentSoftwareOnTheWorkstations
How To Update The ARGOS Instrument Software During Commissioning It is essential that the engineers know exactly which software modules run during the commissioni...
HowToUseLBTOPointingTool
This tool has made available to ARGOS since 13 03 2016 (see Steve Allanson's e mail). This tool allows to offset the telescope optics (independently on each side,...
HowToUseTheFiberSwitch
Usage of the Fastlink Fiber Switch The Fiber Switch is a device installed in the Treehouse to configure FastLink fibers for ARGOS operation. This one superseed ...
Number of topics: 44
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback