AvtCamera
Description The 3 patrol camera units in each LgswUnit are based on AVT GC1350 cameras. The 12V power supply is installed in the MoCon. The ethernet cable is conn...
BCU
The BCU is acting as: frame grabber, slope computer, High Voltage Controller for the tip tilt mirrors, collector of slopes from the FLAO BCU and from the TipTiltU...
BeamCorrector
Description The beam correctors get rid of the astigmatismus the deformed UoA LMs introduce Documentation attach and describe datasheets and documents Installat...
CableAdaptorBoxMocon
Description This cables connects the StepperMotorAdaptorBox to the MoCon. They are 1 to 1 cables with military connectors on both side. Each cable is used to cont...
CablePiezoBcu
Description Cables used to connect the PI S334 to the BCU. Each piezo head has 5 cables terminated with LEMO connectors: 3 for the HV commands (Axis 1, Axis 2, 10...
CalUnitSystem
The CalUnitSystem (or Calibration Unit) is the ARGOS source used for AO calibration in day time. It creates 3 beams that mimics the 3 LGS beams: 532nm narrow band...
DarkWheel
Description The dark wheel consists of the mechanical wheel and the DarkWheelMotor (a motor and a limit switch board with Hall sensor). The magnet is glued on the...
r4 - 21 Jan 2014 - 14:20 by TommasoMazzoni
DarkWheelMotor
Description The dark wheel motor consists of the motor and the limit switch board with Hall sensor. The magnet is glued on the wheel. The motor and the limit swit...
NEW - 21 Jan 2014 - 14:21 by TommasoMazzoni
DeviceTypeTemplate
Documentation attach and describe datasheets and documents Installation and maintenance describe what is needed to put a new device of this kind into operation s...
DichroicController
This is a RTA Xmind K ??? controller to control 1 axis of a dichroic unit. See also DichroicControllerAndWebIOModule Documentation * Programmer manual * In...
DichroicControllerAndWebIOModule
Description It is a rack mount 4U module containing 2 DichroicControllers, 1 LedSources, 1 web i/o interfaces. They are used for .... Documentation * Control ...
ElectronicRackCRing
Description There are 2 C ring electronic racks is installed on the LBT C ring extension. They contains shared devices between the whole ARGOS system. Since they ...
ElectronicRackLLP
Description There are 2 electronic racks is installed on the Laser Launch Platform. They contains power distribution, cooling and other LAS devices. They contain ...
ElectronicRackLSP
Description There are 2 electronic racks is installed on the Laser Supply Platform. They contains power distribution, cooling and other LAS devices. They are atta...
ElectronicRackLgsw
Description The LGSW electronic rack is installed on the LUCI platform. It contains all the devices to control the LgswUnit and the LgswDichroic. It needs 110VAC ...
EthernetCablesPatrolCamera
Bundle with three Ethernet Cables (blue, yellow, red) for Patrol Cameras Documentation attach and describe datasheets and documents Installation and maintenance...
NEW - 23 Jan 2014 - 13:53 by TommasoMazzoni
EthernetCablesThor
Ethernet Cables for InternalTemperatureMonitor (WavecommThor). Documentation http://it.rs online.com/web/p/products/468 6276/?origin=PSF_412635 QVBasket%20Summar...
InnoLasLaserHead
Description The InnoLas NANIO 532 18 Y laser head Documentation * Laser Datasheet: nanio_532_18_y.pdf * Laser User and Installation Manual: nanio_user_en_...
InternalThorCables
Bundle with one EthernetCablesThor and one PowerCableThor (6m). Documentation attach and describe datasheets and documents Installation and maintenance describ...
LanSystem
Description The term "LAN System" refer to all the HW and SW related to the ARGOS launch system on a single LBT eye. A LAN System includes all the components from...
LasSystem
Description The term "LAS System" refer to all the HW and SW related to the ARGOS laser system on a single LBT eye. A LAS System includes a LAS Unit (the box cont...
LedSourceFibers
Bundle with three Optical Fiber (THORLABS, BFL48 600), going from LedSources to LgswUnit. Total of 7 fibers were bought. 6 are grouped, 1 is alone as spare in the...
LedSources
Documentation Technical documents * DCS_user_manual.pdf: Diode Current Source user manual (JZ). * DSQ3K_user_mode software_manual.pdf: DSQ3K driver user mo...
LgswDichroicSystem
Description Documentation Design document: Low_inc_dichroic_report_v1.7.pdf For informations about the motor controllers hosted in the electronic rack see Dichro...
LgswSystem
Description The term "LGSW System" refer to all the HW and SW related to the ARGOS laser guide star wavefront sensor on a single LBT eye. An LGSW system is compos...
LgswTable
Description The table bolted to the rotator gallery on which the LgswUnit is clamped. It also hosts the cooling line manifold Documentation attach and describe ...
LgswUnit
Description The black, t shaped box containing the LGSW WFS. Includes patrol camera, Pockels cell driver and detector Documentation attach and describe datasheet...
MoCon
Documentation * MoCon_Features.pdf: MoCon features (2 pages brochure) * MOCON_UG_1.00.pdf: Complete MoCon User Guide * MoCon_Programmers_Guide_1.07.pdf: Mo...
MoConSMD8Board
Description SMD8 V2 board to drive stepper motors Documentation attach and describe datasheets and documents Installation and maintenance describe what is neede...
MoconBoard
Description The Mocon V2 board that is inserted in the MoCon. It manages communication to the MoCon modules Documentation See MoCon for manuals. Installation an...
MotorControllerAndLedSource
Description It is a rack mount 4U module containing motor controllers for the LMs shutters, 1 LedSources, 1 web i/o interfaces. Documentation Cabling schematics:...
NewportNSA12StepperMotors
Description These motors are used to adjust the pupil position in the LgswUnit. They are customized: the connector has been replaced with a DB9 to plug into the S...
OzonePump
Description These are diaphragm pumps used to extract air from the EM shield in the LgswUnit where the PockelsCells are installed. These devices were added to the...
PiezoController
Description The servo switches are intended to choose, if the piezos are operated in open (off) or closed loop (on). Upper switch: X axis Lower switch:Y axis Doc...
PiezoPIS334
Description Jitter compensation in the LGSW is done by piezo platform PI S334.1SL Documentation attach and describe datasheets and documents Installation and ma...
PockelsCellAmplifier
Description A device in the rack with an on off button and a potentiometer to adjust HV tension. This is an obsolete model, it has been upgraded in Jun 2015. See ...
PockelsCellAmplifierV2
Description A device in the ElectronicRackLgsw to supply high voltage to the PockelsCellDriverV2. This is a replacement of PockelsCellAmplifier, in operation sinc...
PockelsCellDriver
Description This device is installed on a side of the LgswUnit. This is an obsolete device, replaced by PockelsCellDriverV2 Documentation attach and describe dat...
PockelsCellDriverV2
Description This device is installed on a side of the LgswUnit. This is the current version of the device, replacing PockelsCellDriver Documentation attach and d...
PockelsCells
Description Versions The are several version of this device: * The 2012 model (aka v1.0) that have shown degradation of plastic holders due to ozone pollution...
PockelsCellsDriverToAmplifierCables
Description There are 2 versions of these cable boundles: * The 2012 version, serving the PockelsCellAmplifier: it is a boundle of 5 cables, 4 coaxials with BN...
PowerCableThor
Power line cable for WavecommThor. Male: http://it.rs online.com/web/p/connettori din/5336720/ Female: http://it.rs online.com/web/p/connettori din/5334881/ Inter...
PowerCablesPatrolCamera
Bundle with three power line cables for Patrol Camera. Documentation attach and describe datasheets and documents Installation and maintenance describe what is ...
NEW - 23 Jan 2014 - 13:56 by TommasoMazzoni
QuantumComposer
Quantum Composer 9530 series pulse generator Documentation attach and describe datasheets and documents 9530_Manual.pdf Installation and maintenance describe wh...
NEW - 24 Jan 2014 - 10:45 by TommasoMazzoni
RTAStepperMotors
Description These motors are used to move Dichroic and Fold Mirror in the LgswDichroicSystem. Official name: Sanyo Denki, SM2862 5055 Documentation SM_2862 5055....
NEW - 21 Jan 2014 - 09:51 by TommasoMazzoni
StepperMotorAdaptorBox
Description Adaptor box is installed inside the LgswUnit. It gets up to 8 motor connected via DB9 connection on the internal side. On the external side it has 2 m...
StorageCabinet
Documentation attach and describe datasheets and documents Installation and maintenance describe what is needed to put a new device of this kind into operation s...
TemperatureCtrlAndAux
Description This device monitors the temperature and humidity values of the LaserSystem. Documentation * User manual: http://abell.as.arizona.edu/~hill/xlbt...
ThorSensor
Description Sensors with Sensirion SHT21 and RJ connector assembled by Wavecomm. There are several kinds of probes: 1 The ones named THxx with xx greater than ...
TipTiltSystem
Description The Tip Tilt System is composed by: * An ApertureWheel used to set the Tip Tilt system FoV * A QuadCellUnit installed on the technical viewer ar...
TipTiltUnit
Description This is the Tip Tilt Unit that is made of: i. the TipTiltComputer a.k.a. Bonn unit i. the TipTiltIOSwitch a.k.a. Moxa N port i. the APDModule...
r7 - 26 Apr 2016 - 15:11 by TommasoMazzoni
VibrationSystem
Description The ARGOS vibration control system is designed to detect vibrations on the instrument optical path at a level sufficient to calculate and mitigate the...
VibrationSystemDx
Documentation attach and describe datasheets and documents Installation and maintenance describe what is needed to put a new device of this kind into operation s...
VibrationSystemSx
Documentation attach and describe datasheets and documents Installation and maintenance describe what is needed to put a new device of this kind into operation s...
WavecommThor
Documentation User manual (ITA): ARGOS_THOR_MU_20130201.pdf Default configuration: * IP: 192.168.1.150 * Netmask: 255.255.255.0 * Gateway: 192.168.1.254 ...
WfsCamera
Description A WfsCamera device is the fast speed camera of the SH WFS unit. It is installed at the end of the LgswUnit. This topic refers only to the camera head....
WfsCameraElectronicsRack
Description A device in the ElectronicRackLgsw, composed by PcKontron, Sequencer, TemperatureController and PowerSupply Documentation attach and describe datashe...
r4 - 26 Aug 2015 - 09:09 by GillesOrban
WfsCameraPump
This is the pump that is needed to vacuum the WfsCamera Checking camera housing pressure and pumping it out Reading the pressure * The software pressure measu...
WfsCameraToRackCables
Description This is a big boundle of cables connecting the WfsCamera to its electronic inside the ElectronicRackLgsw Documentation attach and describe datasheets...
r2 - 26 Aug 2015 - 09:04 by GillesOrban
WorkStation
Description The ARGOS workstations. They are DELL PowerEdge R510 and R520 See the twiki of MPIA: https://svn.mpia.de/trac/gulli/argos/wiki/Workstations Refer to M...
Number of topics: 60
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.