This procedure brings up the LGSW system until the WFS is ready for on-sky operation

  1. See FullARGOSStartUpProcedure for prerequisites: chiller, main power, login into workstation
  2. Start LGSW software:
  3. In the LGSW Controller GUI, click on "Power Up". Check that the state moved to "Powering Up".
    Clipboard01.jpg
  4. While the system is "Powering Up" check that the WFS camera is cooling down: in the LGSW Lab GUI go to the "WFS" tab and "Basic" subtab. Check in the Statuses that the Cooling is "CoolingOnAndCoolingDown". Go and take a coffee, it will take 20 minutes.
    Clipboard02.jpg
  5. When the "PnCCD Status" will turn to "Ready To Observe" the LGSW Controller state will turn to "Powered Up".
  6. In the LGSW Controller GUI, tick "init pupil motors" and "init dark wheel motor". Click on "Set Up" and wait until state is "Set up".
  7. In the LGSW Controller GUI, click on "Start Up" and wait until state is "Started Up"
  8. In the LGSW Controller GUI, click "Prepare for Observation".
  9. Blah blah, about acquisition.

Topic attachments
I Attachment Action Size Date Who Comment
Clipboard01.jpgjpg Clipboard01.jpg manage 76 K 23 Feb 2015 - 18:31 MarcoBonaglia  
Clipboard02.jpgjpg Clipboard02.jpg manage 67 K 23 Feb 2015 - 18:46 MarcoBonaglia  
This topic: ARGOS > WebHome > FullARGOSStartUpProcedure > HowToPowerUpLGSW
Topic revision: 24 Feb 2015, LorenzoBusoni
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback