This procedure brings up the LAN system until the launch system is ready for on-sky laser propagation
See
FullARGOSStartUpProcedure
for prerequisites: chiller, main power, login into workstation
Start LAN software:
For DX follow
HowToStartSoftware#Start_DX_LALAS_software
For SX follow
HowToStartSoftware#Start_SX_LALAS_software
In the LAN Controller GUI, click on "Power Up" and wait until the end of "Powering Up". The state will be "Powered Up"
In the LAN Controller GUI, check "init Focuser". Click on "Set Up" and wait.
In the LAN Controller GUI, click on "Start Up" and wait until state is "Started Up"
In the LAN Controller GUI, click "Prepare for Observation". This will open the dust shutters.