Pre-requisits: Procedure
  • Open AArb (ARGOS Arbitrator) GUI
    • Command line: argos_?x_arbitrator_engineering_gui
    • On Desktop: Go Application -> Argos ?X -> arbitrator
  • Tab 'Main': Press 'Power up'
    • All controllers should be in "UNKNOWN", in state "POWERED_OFF" do "Restart" first
    • This will take a while. End state will be
    • Sources taking the most time are:
      • LAS: Warming up lasers (end status: Standby 1 shutter closed)
      • LGSW: Cooling down the CCD (end temperature -20deg)
  • Tab 'Main': Press 'Set up'
    • This will initialize motors and BCU. Important step in case of recovery!
  • Tab 'Main': Press 'Start up'
    • Lasers should be minimum in class 1 to succeed
    • Lasers will emit light within the laser box
  • Tab 'Main': Press 'Prepare'
    • This state change will check the connection to the AOS and FLAO.
Notes:
  • Yellow transition states can not be interrupted and do not accept command!
  • Overall system can be monitored in a status GUI:
    • Command line: argos_?x_status_gui
    • On Desktop: Go Application -> Argos ?X -> argos all ?x status gui

-- MarcoBonaglia - 21 Feb 2018