Children of DiaryRun12 in ARGOS Web

Results from ARGOS web retrieved at 12:37 (GMT)

DayTime20160510
13:30: Arrival at telescope 16:00: we try to start up both systems. Due to power outage the SX LGSW computer was off, we turned it on again. The DX LGSW computer ...
DayTime20160511
LgswUnitSx and LgswUnitDx HW servicing 8:00: we unpack the PCD and the amplifier from 3L boxes, we bring it to 5. We also spend 1:30h in searching for the WfsCame...
DayTime20160512
5:30: Gustavo deploys the arm, we have pbl starting AdSecSx: it periodically faild while loading the DSP program. We try many times to power cicle. LB finally can...
r6 - 13 May 2016 - 15:16 by TommasoMazzoni
DayTime20160513
TT w/ Pyr Bin4 test 8:00: we start with PyrWfs, setup as Bin4, mag 15. * CCD47 is not set to Bin16 during the preset * TS at Bin4 is missing the KL basis at...
DayTime20160514
Laser Power Test Measured sum power: * SX 43.256 * DX 48.631 SIDE L1 L2 L3 DX Field cam 15.50 18.06 18.17 DX Calorimeter 15.59 17.06 15.63 SX ...
r9 - 15 May 2016 - 07:33 by TommasoMazzoni
DayTime20160515
Fast guiding check w/ oscilloscope 11:30: Tommaso and Sebastian go on the telescope to check the Fast Guiding delay. We connect an oscilloscope after the 10x divi...
NightTime20160515
18:00: back to SX, we setup for the night We start testing the new telescope offset procedure. We have a first try and the AOS hangs: Mar May 16 03:05:56 DX syste...
NightTime20160516
20:00: we are on sky with lasers 20:30: FLAO fails, CCD39 was off at 3:29:49, we had an error in the FYSOM state machine for OPT.LOOPBUF NOMAD 1499_0210548 * ...
NightTime20160517
DT: training of XY on SW and HW LgswUnitSx calibrations 20:30: we deploy the cal unit and we try to do SX calibrations SX HEXA 2.79 0.32 0.78 208 3...
NightTime20160518
BCU SX debugging 15:00: we start to check the behaviour of the SX BCU. We notice that the main issue is when the Pyramid slopes are enabled. On DX we measure slop...
NightTime20160519
20:00: problems w/ Sx AdSec, it goes in panic mode at each restart. SDSS J13432.85 415503 20:39: AdSec started. Propagate lasers. TN AO Gain AO CL TT Res...
NightTime20160520
03:15UT: doing flats. SDSSJ1110 6459 03:45UT: loop closed. TN AO Gain AO CL TT Res. WF nm rms HO Res. WF nm rms AO rec DIMM " JCL PCL N...
NightTime20160521
02:46UT: getting ready, spotters out. SDSSJ1110 6459 03:00UT: telescope collimated. 03:09UT: loop closed, including spot optimization, at first try! usual mask a...
NightTime20160522
Late opening for technical reasons SDSSJ1110 6459 04:10UT Loop closed 04:24UT We keep on being visited by airplanes 04:45UT Un po di snapshot al passare delle n...
NightTime20160523
Laser head exchange DX Laser 2 with Head #4 was exchanged by Head #5 Laser power measurement. DX Laser 1 Laser 2 Laser 3 Field measurement 16.01 1...
NightTime20160524
03:00UT: Si sale a controllare il DichroicSX che non si muove correttamente. Non si capisce bene, sembra che il Fold Mirror duri fatica a partire. Nel pomeriggio ...
Number of topics: 16
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback