Backlinks to DiaryRun11 in all Webs (Search ARGOS Web only)

Results from ARGOS web retrieved at 02:55 (GMT)

Commissioning
Commissioning run diaries Run 1st day Run ID Description 20111128 Run # 1 Nov 2011 Installation of dichroic interfaces 20130614 Run Installati...
DayTime20160307
13:00 arrival at telescope SX PnCCD pumped (WfsCamera1). Before pumping the SW red 49.5mbar, after pumping 0.02mbar. DX PnCCD (WfsCamera2) was fine, no pumping ne...
r2 - 10 Mar 2016 - 02:08 by GillesOrban
DayTime20160308
8:20: SX CalUnit is in Hexapod set ack to December position: 4.98; 0.39; 0.61; 211; 100 , and FLAO board to: 73.8; 45.9; 45.0 . PBL with crane give us no te...
DayTime20160309
In the morning telescope is dedicate to LUCI1 MOS exchange. 12:15: telescope released, SX and DX CalUnit deployed. LgswUnitSx FoV measurement We do a sweep of /...
DayTime20160310
7:30: power up of DX and SX systems. RR cubes are mounted back on both sides. Side PCT SX DX TipTiltSystemSx calibrations We setup the SX AGW...
DayTime20160311
SX QC and Pyramid co pointing We switch on the AGW and we configure it to be used with IS. FW1: 600 1000, we center on QC. Board 72.3 50.1 35.0 Then w...
r4 - 07 Apr 2016 - 12:44 by TommasoMazzoni
DayTime20160312
LgswUnitDx FoV adjustment to CalUnit We adjusted the position of the LGSW EW to match the cal unit sources, below a summary of the measurements: * 20160312_DX ...
r2 - 11 May 2016 - 22:23 by TommasoMazzoni
NightTime20160312
19:30: telescope open, flats taken, we notice a strange pattern on LUCI1 detector, probably it is due to consensation on LUCI entrance window. NGC2419 20:20: pre...
NightTime20160313
16:00: calibration of Hexapod to Patrol Cameras on the SX system: REC= 20160313_220000. This will be used for the fast laser guide w/ HVC green channel... Truth s...
NightTime20160314
PockelsCellsTransmission test Before starting the night we measure SX PCT, on DX side we have the broken SX driver: Side PCT SX ^ 19:00: teles...
NightTime20160315
Measurement of jitter maximum stroke We checked first the conversion scale between PI mrad and camera pixel: the full FoV (~4.5" is spanned in 11.3mrad of mirror ...
NightTime20160316
20:00: long downtime due to SW failure, we restarted everything several times GAL192 preset sent as mag 12, mag 17 on TS (FW1=90 10) LBFC: corrector @ 250 steps,...
Number of topics: 12

No backlinks in public webs
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback