You are here: Foswiki>ARGOS Web>Commissioning>DiaryRun19>DayTime20180221 (22 Feb 2018, TommasoMazzoni)Edit Attach

DX AO calibration

New Flao Rec Bin2, KL_v22: 20180217_202826

New Flao Rec Bin4, KL_v22: 20180219_193910

Procedure to set the new Flao rec in ARGOS: HowToBuildFlaoAndTrueSensRecsForArgos


CL on 10 modes

MH 50 modes: 20180221_173200

IM 50 modes: 20180221_174929

LGSW REC 50 modes: 20180221_175200


CL on 50 modes

MH 150 modes: 20180221_175400

IM 150 modes: 20180221_180023

LGSW REC 150 modes: 20180221_180400


CL on 150 modes

MH 150 modes: 20180221_175400

IM 150 modes: 20180221_184136

LGSW REC 150 modes: 20180221_184300

CREC:
LGSW only 20180221_184400
Flao Bin2 20180221_194600
Flao Bin4 20180221_235700
QC 20180221_194900

New Hexapod position:
-1.91 -2.62 0.5 -122 51

Test of new Rec with disturbance:
TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20180222_002107 1.2,0.5,0.4 T 88.3177 43.2277 20180221_235700 -1 T F bin4, 0.8"
20180222_002135 1.2,0.5,0.4 T 94.55 43.2824 20180221_235700 -1 T F bin4, 0.8"
20180222_002351 1.4,0.5,0.4 T 73.8316 56.0694 20180221_235700 -1 T F bin4, 1.2"
20180222_002408 1.4,0.5,0.4 T 72.9462 56.1992 20180221_235700 -1 T F bin4, 1.2"
20180222_004941 1.4,0.5,0.4 T 47.7592 64.1223 20180221_194600 -1 T F bin2, 1.2"
20180222_010832 1.4,0.5,0.4 T 54.8768 49.5231 20180221_194600 -1 T F bin2, 0.8"

Below a comparison between to recontructor. The new reconstructor works better.
TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20161206_180832 1,0.5,0.5 T 44.5001 58.9482 20161204_194600 -1 T F
20180222_002107 1.2,0.5,0.4 T 88.3177 43.2277 20180221_235700 -1 T F
20180221_oldNewRec.png

-- TommasoMazzoni - 22 Feb 2018
Topic revision: r1 - 22 Feb 2018, TommasoMazzoni
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback