LgswSystemSx test with sinusoidal REC

  • Old REC
TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20170504_005849 0.5,0.3,0.2 T 143.733 37.7286 20170303_221300 -1 T F
20170504_005915 0.5,0.2, 0 T 148.549 38.9562 20170303_221300 -1 T F
20170504_005926 0.5,0.2, 0 T 141.875 39.0794 20170303_221300 -1 T F
20170504_005944 0.5,0.3,0.1 T 145.76 37.0132 20170303_221300 -1 T F
20170504_005956 0.5,0.3,0.1 T 140.512 34.8912 20170303_221300 -1 T F
20170504_010113 0.5,0.3,0.2 T 134.326 35.6692 20170303_221300 -1 T F
20170504_010123 0.5,0.3,0.2 T 136.514 36.732 20170303_221300 -1 T F
20170504_010147 0.5,0.4,0.3 T 137.515 40.6365 20170303_221300 -1 T F
20170504_010158 0.5,0.4,0.3 T 141.025 41.1051 20170303_221300 -1 T F
20170504_010214 0.5,0.5,0.4 T 149.345 44.0365 20170303_221300 -1 T F
20170504_010223 0.5,0.5,0.4 T 134.159 43.6491 20170303_221300 -1 T F
20170504_010246 0.5,0.5,0.5 T 145.596 134.519 20170303_221300 -1 T F
20170504_010258 0.5,0.5,0.5 T nan nan 20170303_221300 -1 T F
20170504_010246_SlopesRms2D.png

  • New REC w/ sinusoidal TT removal (?)

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20170504_011912 0.5,0.2, 0 T 50.6623 42.6859 20170503_170600 -1 T F
20170504_011922 0.5,0.2, 0 T 55.0776 41.8218 20170503_170600 -1 T F
20170504_011938 0.5,0.3,0.1 T 48.1062 35.1814 20170503_170600 -1 T F
20170504_011948 0.5,0.3,0.1 T 52.0198 36.1322 20170503_170600 -1 T F
20170504_012001 0.5,0.4,0.2 T 49.8187 37.4321 20170503_170600 -1 T F
20170504_012010 0.5,0.4,0.2 T 54.7605 36.7312 20170503_170600 -1 T F
20170504_012038 0.5,0.5,0.3 T 50.6541 37.3373 20170503_170600 -1 T F
20170504_012055 0.5,0.5,0.4 T 52.8002 37.8114 20170503_170600 -1 T F
20170504_012104 0.5,0.5,0.4 T 45.6163 38.2692 20170503_170600 -1 T F
20170504_012118 0.5,0.5,0.5 T 50.5933 39.2147 20170503_170600 -1 T F
20170504_012128 0.5,0.5,0.5 T 55.5428 38.3184 20170503_170600 -1 T F

20170504_012128_SlopesRms2D.png

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20170504_012513 0.5,0.2, 0 T 48.682 232.947 20170503_170600 -1 T F dist= 0.8"
20170504_012522 0.5,0.2, 0 F 47.9482 233.233 20170503_170600 -1 T F dist= 0.8"
20170504_012535 0.5,0.3,0.1 T 46.6161 110.914 20170503_170600 -1 T F dist= 0.8"
20170504_012544 0.5,0.3,0.1 T 50.5344 110.916 20170503_170600 -1 T F dist= 0.8"
20170504_012559 0.5,0.4,0.2 T 45.8958 77.0525 20170503_170600 -1 T F dist= 0.8"
20170504_012608 0.5,0.4,0.2 T 46.4734 76.2952 20170503_170600 -1 T F dist= 0.8"
20170504_012624 0.5,0.5,0.3 T 52.1728 62.4633 20170503_170600 -1 T F dist= 0.8"
20170504_012634 0.5,0.5,0.3 T 55.0572 62.9107 20170503_170600 -1 T F dist= 0.8"
20170504_012649 0.5,0.5,0.4 T 51.2356 57.1961 20170503_170600 -1 T F dist= 0.8"
20170504_012658 0.5,0.5,0.4 T 47.1951 57.1764 20170503_170600 -1 T F dist= 0.8"
20170504_012712 0.5,0.5,0.5 T 47.8943 55.8153 20170503_170600 -1 T F dist= 0.8"
20170504_012728 0.5,0.5,0.5 T 46.8518 55.8412 20170503_170600 -1 T F dist= 0.8"