You are here: Foswiki>ARGOS Web>Commissioning>DiaryRun15>DayTime20170304 (26 Jun 2017, TommasoMazzoni)Edit Attach

DX AO test

New flat on DX adsec with 400 modes made in CL with FLAO.

Test old recontrstuctor with 0.8" disturbance.
TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20170304_222153 0.75,0.5,0.4 T 73.4569 59.6677 20161205_222600 -1 T F
20170304_222214 0.75,0.5,0.4 T 68.3518 58.9611 20161205_222600 -1 T F
20170304_222229 0.75,0.5,0.4 T 63.5883 59.6827 20161205_222600 -1 T F

Test new LookUp Table of the offload for the Pyramid Tip Tilt Mirror to keep the pointing stable on LUCI changing the rotator angle.

SX AO test

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20170304_205624 0.5,0.4,0.3 T 177.272 50.6079 20170303_221300 -1 T F
20170304_231411 0.5,0.25,0.15 T 163.59 42.8248 20170303_221300 -1 T F rotator

DX test TT offset with rotator

TN AO Gain AO CL TT Res. WF [nm rms] HO Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes
20170304_223624 0.75,0.4,0.25 T 68.6698 30.7439 20161205_222600 -1 T F
20170304_223829 0.75,0.4,0.25 T 64.8029 37.0947 20161205_222600 -1 T F
20170304_223943 0.75,0.4,0.25 T 71.4328 36.1418 20161205_222600 -1 T F
20170304_224121 0.75,0.4,0.25 T 66.5737 38.4641 20161205_222600 -1 T F
20170304_224436 0.75,0.4,0.25 T 69.134 34.776 20161205_222600 -1 T F
20170304_224611 0.75,0.4,0.25 T 73.964 40.2068 20161205_222600 -1 T F
20170304_224838 0.75,0.4,0.25 T 73.6312 36.6024 20161205_222600 -1 T F
20170304_225246 0.75,0.4,0.25 T 84.45 35.5451 20161205_222600 -1 T F
20170304_225520 0.75,0.4,0.25 T 76.0098 35.9311 20161205_222600 -1 T F
20170304_225645 0.75,0.4,0.25 T 75.3967 36.9485 20161205_222600 -1 T F
20170304_225821 0.75,0.4,0.25 T 79.0553 35.0354 20161205_222600 -1 T F
20170304_225954 0.75,0.4,0.25 T 85.9075 34.8591 20161205_222600 -1 T F
20170304_230959 0.75,0.4,0.25 T 65.2825 29.1031 20161205_222600 -1 T F
20170304_231203 0.75,0.4,0.25 T 76.1519 29.248 20161205_222600 -1 T F
20170304_231322 0.75,0.4,0.25 T 78.3714 29.0003 20161205_222600 -1 T F
20170304_231442 0.75,0.4,0.25 T 66.4601 28.3141 20161205_222600 -1 T F
20170304_231603 0.75,0.4,0.25 T 64.9188 28.8726 20161205_222600 -1 T F
20170304_231724 0.75,0.4,0.25 T 68.5514 29.14 20161205_222600 -1 T F
20170304_231942 0.75,0.4,0.25 T 64.3156 29.0361 20161205_222600 -1 T F
20170304_232139 0.75,0.4,0.25 T 71.6859 30.2758 20161205_222600 -1 T F
20170304_233114 0.75,0.4,0.25 T 75.3771 29.3844 20161205_222600 -1 T F
20170304_233244 0.75,0.4,0.25 T 74.0967 30.5009 20161205_222600 -1 T F
201170304_233244_TT_LUT.png

201170304_233244_RotVsModalOffset_mode2.png

201170304_233244_RotVsModalOffset_mode3.png

201170304_233244_RotVsModalOffset_mode4.png

201170304_233244_rot_boardPos.png

-- TommasoMazzoni - 14 Mar 2017
Topic revision: r4 - 26 Jun 2017, TommasoMazzoni
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback