Morning: FLAO communication debugging... no real output.

13:00: FLAO comminication star to work... we setup to close TT on PYR, no disturb

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Modalplot
20151213_211353 0.95,0.45,0.45 108.069 20151211_202800 -1 T F 20151213_211353-20151213_212227_modalplot.png
20151213_211513 1.1,0.35,0.35 87.3731 20151211_202800 -1 T F
20151213_212227 0.5,0.5,0.5 187.55 20151212_220700 -1 F F
Pupils were misplaced, we set them back to the original position used to acquire IM:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151213_212324 0.5,0.45,0.4 165.385 20151212_220700 -1 F F - 20151213_212324-20151213_212359_modalplot.png
20151213_212350 0.5,0.4,0.4 167.839 20151212_220700 -1 F F
20151213_212359 0.5,0.4,0.4 170.709 20151212_220700 -1 F F
20151213_212715 0.5,0.5,0.5 174.349 20151212_220700 -1 F F all pupils down by 5st 20151213_212715-20151213_213400_modalplot.png
20151213_212847 0.5,0.5,0.5 190.112 20151212_220700 -1 F F all down 10 st
20151213_212952 0.5,0.5,0.5 185.576 20151212_220700 -1 F F original
20151213_213400 0.5,0.5,0.5 172.144 20151212_220700 -1 F F pup pos opti by eye
So we set motors in the following position:

Beam X Y
Blue 320 430
Yellow 370 458
Red 495 432
Pupil target tag: 20151213_214805

Board -74.1 -45.7
So to resume we must set an offset of [3.4; 3.4]mm in the AARB.

HEXA 4.28 -0.077 -0.754 250 -158

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151213_214903 0.5,0.5,0.5 182.932 20151212_220700 -1 F F . 20151213_214903-20151213_214924_modalplot.png
20151213_214924 0.5,0.5,0.5 177.832 20151212_220700 -1 F F .
Then we load 1" equivalent disturb:

TN AO Gain Res. WF [nm rms] AO rec DIMM ["] JCL PCL Notes Modalplot
20151213_215643 1,0.4,0.4 86.5389 20151211_202800 -1 T F 20151213_215643-20151213_221353_modalplot.png
20151213_220506 0.5,0.4,0.35 95.7312 20151211_202800 -1 T F
20151213_220557 0.5,0.4,0.35 92.4656 20151211_202800 -1 T F
20151213_221059 0.5,0.4,0.35 116.611 20151211_202800 -1 T F TS coverged at 2nm rms
20151213_221145 0.5,0.4,0.4 117.548 20151211_202800 -1 T F
20151213_221204 0.5,0.4,0.4 109.866 20151211_202800 -1 T F
20151213_221353 0.5,0.45,0.45 120.934 20151211_202800 -1 T F

-- MarcoBonaglia - 13 Dec 2015
Topic revision: r2 - 08 Jan 2016, MarcoBonaglia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.