SX T-Gusset installation
At horizontal tube, turn upper shaft fully in.
At inclined tube, turn shaft only so far that there is the same distance in both direction from the middle.
On upper shaft put nut on up to the middle (take care that it is done in the right way. Pins toward the tube)
Lower nut already fixed on T-Gusset.
Attach T-Gusset on lower shaft.
Turn lower shaft until upper nut fits in.
Fix pins and adjust pins to T-Gusset (you might have to play a bit with lower shaft.
What is important:
Nut with pins toward tube.
Upper flexures should have play, lower flexures have to be the tight ones.
--