9:00: dichroic & CalUnit in

M3 -758 580 0 -25.9

Hexapod coma free movements:

X= 0.982mm, Ry= 102"

Y= -0.982mm, Rx= 102"

Slided Red entrance window by +0.6mm in Rx, we measure again flux vs hexapod position, see DayTime20141102

11:00: we center again pupils to redefine subaps

Pupil X Y
Blue 755 512
Yellow 291 720
Red 457 672

TN Notes
20141103_180039 bad
20141103_180203 bad, yellow out
20141103_180625 new pupil tag used
20141103_181037  
20141103_181108  

Pupil Tag: 20141103_180704

Center of the Blue pupil @ [128; 196], Yellow @ [64; 82], Red @ [197; 80].

We remove subaps # 89 (blue central), 66, 81, 96, 111, 126 (blue top row), 266 (yellow central), 443 (red central).

Since they are odd we add 1 fake subap (# 1000).

Subaps: 20141103_192000

12:00: Gilles finishes to update BCU firmware.

We load new subapertures, but we need to disable ADC clocking before reconfigure BCU.

TN: 20141103_200209 CL with new subaps.

Slope offset: 20141103_200740

Enabling the OVS disturbance has the bit 13 in the ParamBlockSelector. Enable WFS disturbance has bit 12 (the firmware bug that put the same bit of the PixelStorage has been solved).

We record a first IM: 20141103_211531 with jitter loop closed, @ 1kHz

IM: 20141103_212511 @240Hz, after shifting it by 1 we get * IM: 20141103_213259*.

IM : 20141103_215648 from 20141103_211531, but shifted by 31.

*REC: 10modes_blue"

-- MarcoBonaglia - 12 Nov 2014
Topic revision: r1 - 12 Nov 2014, MarcoBonaglia
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback