We start recording the IM for the Yellow pupil @ 150Hz.

REC: 100modesOK

Then we close the loop at 1kHz.

TN Notes
20140510_202224 new Snapshot procedure, closed loop with 100 modes
20140510_202306 "
20140510_202355 old Snapshot, closed loop on 100 modes, gain 0.1
20140510_202424 "
20140510_202941 new SN, open loop
20140510_203003 "
20140510_203025 old SN, open loop
20140510_203740 old SN, CL 100 modes, gain 0.5
20140510_203813 new SN, CL 100 modes, g 0.5
20140510_203840 "

We try to set UDP port 10002 to receive the tubone data from ASM. Fail!

TN Notes
20140510_211438 CL, g 0.1, no TT correction
20140510_211457 "
20140510_211517 "
20140510_211554 CL, g=0.5, no TT
20140510_211637 "
20140510_211734 "
20140510_211931 CL, g=0.5, no TT, jitter loop closed
20140510_211950 "
20140510_212014 "
20140510_221516 CL 150 modes, g=0.2, 1kHz, no jitter
20140510_223440 CL 150 modes, g=0.35 on TT, 0.25 on HO
20140510_223506 "

We recalibrated the amplitude of the modes, each mode is weighted by the slope rms recorded during the IM acquisition. The weighting coefficients are stored here:
/home/argos/calib/DX/aarb/aoloop/amp_calibrated.fits

So all the new IM have the modal amplitudes optimized:

TN Notes Rec
20140510_231120 CL 150 modes, g 0.5 on TT, 0.4 on HO 150modes_optimized.fits
20140510_231149 " "
20140510_231225 " "

We switch to BLUE pupil.

Pupil motor X Y
Blue 798 511
Yellow 295 755

REC: 50modes_ol_blue, 150modes_blue

TN Notes
20140511_000000 CL 150 modes, 1kHz
20140511_000054 OL

DARK: 20140511_000552

17:12 VNC crash...
Topic revision: r2 - 08 Jul 2014, LorenzoBusoni