Summary of AO loop calibrations for the ArgosSystemDx

Description of Low and High orders (from abstract_foreman.py):

class AoLoopGain ():

FIRST_TIP_TILT_MODE= 0
LAST_TIP_TILT_MODE= 1
FIRST_LOW_ORDER_MODE= 2
LAST_LOW_ORDER_MODE= 35
FIRST_HIGH_ORDER_MODE= 36
LAST_HIGH_ORDER_MODE= 672

Table below resumes the latest combined reconstructors built and tested in daytime:
Combination Tag Subaps Combined REC
TCoG48 only 20161205_201600 20190115_234000
TCoG48 bin2 20190119_103300
TCoG48 bin4 20190116_060800
T CoG48 QC 20190119_101036
CoG only 20141126_192200 20150427_125800
CoG bin2 20150427_130000
CoG bin4 20150427_130200
CoGNorm only 20141126_212900 20150427_034400
CoGNorm bin2 20150427_034600
CoGNorm bin4 20150427_034800
WWPA only 20141126_212800 20150427_034500
WWPA bin2 20150427_034700
WWPA bin4 20150427_034900
FLAO bin2 - 20161210_031300
FLAO bin4 - 20170306_211500
Hybrid 20161205_201600 20170311_121600

Combined reconstructors general table

To generate the following table open an argos terminal and type
from argos.terminal.sandbox import makeComboRecTable
makeComboRecTable(argos)

Combined REC Subaps REC0 Type Modes REC0 Tag REC1 Type Modes REC1 Tag
20190119_103300 20161205_201600 LGSW 2 - 150 20190115_021900 FLAO 0 - 1 20190104_203812
20190119_101036 20161205_201600 LGSW 2 - 150 20190115_021900 TIPTILT 0 - 1 20150429_112300
20190116_060800 20161205_201600 LGSW 2 - 150 20190115_021900 FLAO 0 - 1 20190111_193944
20190115_234000 20161205_201600 LGSW 0 - 672 20190115_232400 - - -
20190115_032300 20161205_201600 LGSW 2 - 150 20190115_021900 FLAO 0 - 1 20180219_193910
20190115_022000 20161205_201600 LGSW 0 - 672 20190115_021900 - - -
20190115_014700 20161205_201600 LGSW 0 - 672 20190115_014300 - - -
20190115_011000 20161205_201600 LGSW 0 - 672 20190115_010600 - - -
20181203_093900 20161205_201600 LGSW 0 - 672 20181203_093800 - - -
20181203_084000 20161205_201600 LGSW 0 - 672 20181203_083900 - - -
20181203_041100 20161205_201600 LGSW 0 - 672 20181203_040800 - - -
20181203_033800 20161205_201600 LGSW 0 - 672 20180223_232800 - - -
20181202_201300 20161205_201600 LGSW 0 - 672 20181202_200600 - - -
20181202_201200 20161205_201600 LGSW 0 - 672 20181202_201000 - - -
20181202_201100 20161205_201600 LGSW 0 - 672 20181202_195900 - - -
20181202_022200 20161205_201600 LGSW 2 - 150 20181202_021000 FLAO 0 - 1 20180219_193910
20181201_043200 - FLAO 0 - 153 20180217_202826 - - -
20181201_041500 20161205_201600 LGSW 0 - 672 20180223_232800 - - -
20181201_034700 20161205_201600 LGSW 2 - 150 20181201_033900 FLAO 0 - 1 20180219_193910
20180223_233700 20161205_201600 LGSW 2 - 150 20180223_232800 FLAO 0 - 1 20180219_193910
20180223_233600 20161205_201600 LGSW 2 - 150 20180223_232800 FLAO 0 - 1 20180217_202826
20180221_235700 20161205_201600 LGSW 2 - 150 20180221_184300 FLAO 0 - 1 20180219_193910
20180221_194900 20161205_201600 LGSW 2 - 150 20180221_184300 TIPTILT 0 - 1 20150429_112300
20180221_194700 20161205_201600 LGSW 2 - 150 20180221_184300 FLAO 0 - 1 20180219_193910
20180221_194600 20161205_201600 LGSW 2 - 150 20180221_184300 FLAO 0 - 1 20180217_202826
20180221_184400 20161205_201600 LGSW 0 - 672 20180221_184300 - - -
20180221_182000 20161205_201600 LGSW 0 - 672 20180221_180400 - - -
20180221_035300 20161205_201600 LGSW 0 - 672 20180221_034900 - - -
20180220_233200 20161205_201600 LGSW 2 - 150 20180220_232500 FLAO 0 - 1 20180220_232900
20170311_121600 20161205_201600 LGSW 36 - 150 20161205_215400 FLAO 0 - 35 20130917_214654
20170306_211500 - FLAO 0 - 36 20130917_214654 - - -
20161210_031300 - FLAO 0 - 153 20130916_221257 - - -
20161209_060400 20161205_201600 LGSW 36 - 150 20161205_215400 FLAO 0 - 35 20130917_214654
20161207_190200 20161205_201600 LGSW 2 - 150 20161205_215400 TIPTILT 0 - 1 20150429_112300
20161205_222600 20161205_201600 LGSW 2 - 150 20161205_215400 FLAO 0 - 1 20130917_214654
20161205_222500 20161205_201600 LGSW 2 - 150 20161205_215400 FLAO 0 - 1 20130916_221257
20161205_215600 20161205_201600 LGSW 0 - 672 20161205_215400 - - -
20161204_194600 20160312_213700 LGSW 2 - 150 20160516_092200 FLAO 0 - 1 20130917_214654
20161204_194500 20160312_213700 LGSW 2 - 150 20160516_092200 FLAO 0 - 1 20130916_221257
20161204_194300 20160312_213700 LGSW 2 - 150 20160516_092200 TIPTILT 0 - 1 20150429_112300
20160520_011900 - FLAO 0 - 36 20130917_214654 - - -
20160520_011800 20160312_213700 LGSW 0 - 672 20160516_101200 - - -
20160520_011100 20160312_213700 LGSW 2 - 150 20160516_101200 FLAO 0 - 1 20130917_214654
20160520_010900 20160312_213700 LGSW 2 - 150 20160516_101200 FLAO 0 - 1 20130916_221257
20160520_010700 20160312_213700 LGSW 2 - 150 20160516_101200 TIPTILT 0 - 1 20150429_112300
20160517_005700 20160312_213700 LGSW 2 - 150 20160516_101200 FLAO 0 - 1 20130917_214654
20160517_005600 20160312_213700 LGSW 2 - 150 20160516_101200 FLAO 0 - 1 20130916_221257
20160517_005400 20160312_213700 LGSW 2 - 150 20160516_101200 FLAO 0 - 1 20160303_190311
20160516_101300 20160312_213700 LGSW 0 - 672 20160516_101200 - - -
20160516_092300 20160312_213700 LGSW 0 - 672 20160516_092200 - - -
20160516_081400 20160312_213700 LGSW 0 - 672 20160516_081300 - - -
20160516_060700 20160312_213700 LGSW 2 - 150 20160516_003800 FLAO 0 - 1 20160303_182705
20160516_060600 20160312_213700 LGSW 2 - 150 20160516_003800 FLAO 0 - 1 20160303_190311
20160516_003900 20160312_213700 LGSW 0 - 672 20160516_003800 - - -
20160515_234900 20160312_213700 LGSW 0 - 672 20160515_234300 - - -
20160311_205900 20160310_000900 LGSW 0 - 672 20160311_205800 - - -
20160310_200100 20160310_000900 LGSW 0 - 672 20160310_200000 - - -
20160310_193900 20160310_000900 LGSW 0 - 672 20160310_193700 - - -
20150706_065600 20141126_212700 LGSW 36 - 150 20150704_021100 FLAO 0 - 35 20130917_214654
20150704_021600 - FLAO 0 - 36 20130917_214654 - - -
20150704_021500 20141126_212700 LGSW 2 - 150 20150704_021100 FLAO 0 - 1 20130917_214654
20150704_021400 20141126_212700 LGSW 2 - 150 20150704_021100 FLAO 0 - 1 20130916_221257
20150704_021300 20141126_212700 LGSW 2 - 150 20150704_021100 TIPTILT 0 - 1 20150429_112300
20150704_021200 20141126_212700 LGSW 0 - 672 20150704_021100 - - -
20150703_234700 20141126_212700 LGSW 0 - 672 20150703_104300 - - -
20150703_231700 20141126_212700 LGSW 0 - 672 20150703_104100 - - -
20150703_231300 20141126_212700 LGSW 0 - 672 20150703_104200 - - -
20150703_105200 20141126_212700 LGSW 2 - 150 20150703_104100 FLAO 0 - 1 20130917_214654
20150703_104400 20141126_212700 LGSW 2 - 150 20150703_104200 FLAO 0 - 1 20130917_214654
20150703_074900 20141126_212700 LGSW 0 - 672 20150703_074800 - - -
20150703_065900 20141126_212700 LGSW 0 - 672 20150703_065400 - - -
20150703_065800 20141126_212700 LGSW 2 - 150 20150703_065400 FLAO 0 - 1 20130917_214654
20150703_065700 20141126_212700 LGSW 2 - 150 20150703_065400 FLAO 0 - 1 20130916_221257
20150703_065600 20141126_212700 LGSW 2 - 150 20150703_065400 TIPTILT 0 - 1 20150429_112300
20150701_075700 20141126_212700 LGSW 2 - 150 20150701_074600 TIPTILT 0 - 1 20150429_112300
20150701_075300 20141126_212700 LGSW 2 - 150 20150701_074600 FLAO 0 - 1 20130917_214654
20150701_075200 20141126_212700 LGSW 2 - 150 20150701_074600 FLAO 0 - 1 20130916_221257
20150701_074800 20141126_212700 LGSW 0 - 672 20150701_074600 - - -
20150603_130800 20141126_212700 LGSW 0 - 672 20150603_110200 - - -
20150603_130700 20141126_212700 LGSW 2 - 150 20150525_173700 FLAO 0 - 1 20130917_214654
20150603_130600 20141126_212700 LGSW 2 - 150 20150525_173700 FLAO 0 - 1 20130916_221257
20150603_130000 20141126_212700 LGSW 2 - 150 20150603_110200 FLAO 0 - 1 20130917_214654
20150603_125900 20141126_212700 LGSW 2 - 150 20150603_110200 FLAO 0 - 1 20130916_221257
20150603_125800 20141126_212700 LGSW 2 - 150 20150603_110200 TIPTILT 0 - 1 20150223_095600
20150603_125700 20141126_212700 LGSW 2 - 150 20150525_173700 TIPTILT 0 - 1 20150223_095600
20150603_125600 20141126_212700 LGSW 0 - 672 20150525_173700 - - -
20150603_125100 20141126_212700 LGSW 0 - 672 20150603_124900 - - -
20150603_125000 20141126_212700 LGSW 0 - 672 20150603_124800 - - -
20150603_124800 20141126_212700 LGSW 0 - 672 20150603_124700 - - -
20150603_124600 20141126_212700 LGSW 0 - 672 20150603_124500 - - -
20150603_124300 20141126_212700 LGSW 0 - 672 20150603_124200 - - -
20150502_084900 20141126_212700 LGSW 36 - 150 20150227_023500 FLAO 0 - 35 20130917_214654
20150429_110600 20141126_212700 LGSW 2 - 150 20150227_023500 TIPTILT 0 - 1 20150429_112300
20150427_222222 20141126_212700 LGSW 2 - 672 20150427_215200 FLAO 0 - 1 20130917_214654
20150427_130200 20141126_192200 LGSW 2 - 672 20150427_125500 FLAO 0 - 1 20130917_214654
20150427_130100 20141126_212700 LGSW 2 - 672 20150427_125200 FLAO 0 - 1 20130917_214654
20150427_130000 20141126_192200 LGSW 2 - 672 20150427_125500 FLAO 0 - 1 20130916_221257
20150427_125900 20141126_212700 LGSW 2 - 672 20150427_125200 FLAO 0 - 1 20130916_221257
20150427_125800 20141126_192200 LGSW 0 - 672 20150427_125500 - - -
20150427_125700 20141126_212700 LGSW 0 - 672 20150427_125200 - - -
20150427_093700 20141126_212700 LGSW 2 - 150 20150427_125200 TIPTILT 0 - 1 20150223_095600
20150427_034900 20141126_212800 LGSW 2 - 672 20150427_034200 FLAO 0 - 1 20130917_214654
20150427_034800 20141126_212900 LGSW 2 - 672 20150427_030400 FLAO 0 - 1 20130917_214654
20150427_034700 20141126_212800 LGSW 2 - 672 20150427_034200 FLAO 0 - 1 20130916_221257
20150427_034600 20141126_212900 LGSW 2 - 672 20150427_030400 FLAO 0 - 1 20130916_221257
20150427_034500 20141126_212800 LGSW 0 - 672 20150427_034200 - - -
20150427_034400 20141126_212900 LGSW 0 - 672 20150427_030400 - - -
20150427_024000 20141126_212700 LGSW 2 - 150 20150227_023500 TIPTILT 0 - 1 20150223_095600
20150427_023900 20141126_212700 LGSW 2 - 150 20150227_023500 FLAO 0 - 1 20130917_214654
20150427_023800 20141126_212700 LGSW 2 - 150 20150227_023500 FLAO 0 - 1 20130916_221257
20150427_023600 20141126_212700 LGSW 0 - 672 20150227_023500 - - -
20150427_020100 20141126_212700 LGSW 2 - 150 20150427_125200 TIPTILT 0 - 1 20150223_100400
20150427_015100 20141126_212700 LGSW 0 - 672 20150427_015000 - - -
20150427_012200 20141126_212700 LGSW 0 - 672 20150427_004500 - - -
20150427_012100 20141126_212700 LGSW 0 - 672 20150427_011900 - - -
20150227_024000 - LGSW 2 - 150 20150227_023500 TIPTILT 0 - 1 20150223_095600
20150227_023900 - LGSW 2 - 150 20150227_023500 FLAO 0 - 1 20130917_214654
20150227_023800 - LGSW 2 - 150 20150227_023500 FLAO 0 - 1 20130916_221257
20150227_023600 - LGSW 0 - 672 20150227_023500 - - -
20150227_015100 - LGSW 0 - 672 20150227_015000 - - -
20150227_012200 - LGSW 0 - 672 20150227_004500 - - -
20150227_012100 - LGSW 0 - 672 20150227_011900 - - -
20150224_093700 - LGSW 2 - 150 20141202_125200 TIPTILT 0 - 1 20150223_095600
20150224_020100 - LGSW 2 - 150 20141202_125200 TIPTILT 0 - 1 20150223_100400
20150222_214000 - LGSW 36 - 150 20141202_125200 FLAO 0 - 35 20130917_214654
20141203_034900 - LGSW 2 - 672 20141203_034200 FLAO 0 - 1 20130917_214654
20141203_034800 - LGSW 2 - 672 20141203_030400 FLAO 0 - 1 20130917_214654
20141203_034700 - LGSW 2 - 672 20141203_034200 FLAO 0 - 1 20130916_221257
20141203_034600 - LGSW 2 - 672 20141203_030400 FLAO 0 - 1 20130916_221257
20141203_034500 - LGSW 0 - 672 20141203_034200 - - -
20141203_034400 - LGSW 0 - 672 20141203_030400 - - -
20141203_034053 - LGSW 0 - 672 20141203_034053 - - -
20141203_033717 - LGSW 0 - 672 20141203_033717 - - -
20141203_033444 - LGSW 0 - 672 20141203_033444 - - -
20141203_033017 - LGSW 0 - 672 20141203_033017 - - -
20141203_032751 - LGSW 0 - 672 20141203_032751 - - -
20141203_032444 - LGSW 0 - 672 20141203_032444 - - -
20141203_030243 - LGSW 0 - 672 20141203_030243 - - -
20141203_025847 - LGSW 0 - 672 20141203_025847 - - -
20141203_025452 - LGSW 0 - 672 20141203_025452 - - -
20141203_025127 - LGSW 0 - 672 20141203_025127 - - -
20141203_024709 - LGSW 0 - 672 20141203_024709 - - -
20141203_023042 - LGSW 0 - 672 20141203_023042 - - -
20141203_022557 - LGSW 0 - 672 20141203_022557 - - -
20141203_021923 - LGSW 0 - 672 20141203_021923 - - -
20141203_021017 - LGSW 0 - 672 20141203_021017 - - -
20141202_130200 - LGSW 2 - 672 20141202_125500 FLAO 0 - 1 20130917_214654
20141202_130100 - LGSW 2 - 672 20141202_125200 FLAO 0 - 1 20130917_214654
20141202_130000 - LGSW 2 - 672 20141202_125500 FLAO 0 - 1 20130916_221257
20141202_125900 - LGSW 2 - 672 20141202_125200 FLAO 0 - 1 20130916_221257
20141202_125800 - LGSW 0 - 672 20141202_125500 - - -
20141202_125700 - LGSW 0 - 672 20141202_125200 - - -
20141129_054300 - LGSW 2 - 672 20141129_054100 FLAO 0 - 1 20130916_221257
20141129_054200 - LGSW 0 - 672 20141129_054100 - - -
20141127_222400 - LGSW 2 - 672 20141126_210900 FLAO 0 - 1 20130917_214654
20141127_222222 - LGSW 2 - 672 20141126_215200 FLAO 0 - 1 20130917_214654
20141127_200600 - LGSW 150 - 672 20141126_215200 FLAO 0 - 149 20130916_221257
20141127_185600 - LGSW 0 - 672 20141126_210900 - - -
20141127_185500 - LGSW 0 - 672 20141126_215200 - - -
20141127_180700 - LGSW 2 - 672 20141126_210900 FLAO 0 - 1 20130916_221257
20141127_180600 - LGSW 2 - 672 20141126_215200 FLAO 0 - 1 20130916_221257

QC reconstructors

QC REC QC IM
20150223_095600 ???
20150429_112300 ???

FLAO reconstructors

FLAO REC BIN
20150125_161348 1
20130916_221257 2
20130917_214654 4

LGSW reconstructors

LGSW REC # modes LGSW IM Subaps
20150227_023500 150 20150227_003817 20141126_212700
20150427_125500 150 20141126_210900 20141126_192200
20150427_030400 150 20141203_030231 20141126_212900
20150427_034200 150 20141203_034041 20141126_212800
20150703_065400 150 20150703_064857 20141126_212700
20150703_074800 200 20150703_074729 20141126_212700
20150704_021100 150 20150704_020321 20141126_212700

Subaperture sets

Subaps SC algo
20141126_212700 TCoG48
20160312_213700 TCoG48
20141126_192200 CoG
20151016_170000 CoG
20160310_000700 CoG
20141126_212900 CoGNorm
20141126_212800 WWPA

TM test Reconstructors

The BLUE pupil is vignetted. The calculation of the BLUE reconstructor must take account of this.

Combination Tag IM LGSW REC Combined REC Notes
BLUE old 20150227_003817 20150603_124500 20150603_124600 w/o take account BLUE vignetting
BLUE 120 modes 20150227_003817 20150603_124700 20150603_124800 only 120 modes instead 150
BLUE new 20150525_173100 20150603_124200 20150603_124300 Suppressed the last Singular Value
YELLOW 20150525_173100 20150603_124800 20150603_125000  
RED 20150525_173100 20150603_124900 20150603_125100  
GLAO 1, only lgsw 20150227_003817 20150603_110200 20150603_130800 BLUE 120 modes
GLAO 1, QC 20150227_003817 20150603_110200 20150603_125800 BLUE 120 modes
GLAO 1, pyr bin 2 20150227_003817 20150603_110200 20150603_125900 BLUE 120 modes
GLAO 1, pyr bin 4 20150227_003817 20150603_110200 20150603_130000 BLUE 120 modes
GLAO 2, only lgsw 20150525_173100 20150525_173700 20150701_074800 Suppressed the last Singular Value BLUE
GLAO 2, QC 20150525_173100 20150525_173700 20150701_075700 Suppressed the last Singular Value BLUE
GLAO 2, pyr bin 2 20150525_173100 20150525_173700 20150701_075200 Suppressed the last Singular Value BLUE
GLAO 2, pyr bin 4 20150525_173100 20150525_173700 20150701_075300 Suppressed the last Singular Value BLUE
All these IMs are acquired with the subaperture set 20141126_212700 (TCoG48 algorithm) LGSW reconstructor 20150603_110200 is calculated with 120 modes of the BLUE sensor and 150 modes with the YELLOW and RED sensors. LGSW reconstructors 20150603_124200 and 20150525_173700 are calculated from the IM 20150525_173100 witch is build suppressing the last singular value of the SVD of the BLUE IM.